background image

Commissioning 

Connecting the intermediate tube package to the power source 

 

Item No.:099-OW0008-EWM01

 

 

5.2

 

Connecting the intermediate tube package to the power source 

 

 

 

NOTE 

 

 

  Observe the operating instructions for the wire feed unit and for the power source! 

The steps 
•  connect the intermediate tube package to the wire feed unit, 
•  connect the welding torch, 
•  connect the wire supply, 
• shielding 

gas 

connection 

and other steps are described in the operating instructions for the wire feed unit and the power 
source. 

 

 

5.2.1

 

OW ASM 2. DV PHOENIX PROGRESS K 

 

 

Figure 5-1

 

Содержание OW ASM 2.DV PHOENIX PROGRESS K

Страница 1: ...may be dangerous Machines may only be operated by personnel who are familiar with the appropriate safety regulations The machines bear the conformity mark and thus comply with the EC Low Voltage Direc...

Страница 2: ......

Страница 3: ...DV PHOENIX PROGRESS K 6 3 2 2 OW ASM 2 DV PHOENIX PROGRESS D 6 4 Technical data 7 5 Commissioning 7 5 1 General 7 5 2 Connecting the intermediate tube package to the power source 8 5 2 1 OW ASM 2 DV P...

Страница 4: ...ons for repair work trained service personnel CAUTION Obligations of the operator In the European Economic Area EEA the relevant national version of the basic guidelines must be followed and observed...

Страница 5: ...the unit to operate a second wire feed unit OW ASM 2 DV PHOENIX PROGRESS K also includes OW 2 BOTTLE wide trolly with a bracket for two shielding gas cylinders OW REINFORCED PUMP TP reinforced weldin...

Страница 6: ...General Machine variants 6 Item No 099 OW0008 EWM01 3 2 Machine variants 3 2 1 OW ASM 2 DV PHOENIX PROGRESS K Figure 3 1 3 2 2 OW ASM 2 DV PHOENIX PROGRESS D Figure 3 2...

Страница 7: ...lectric shock Contact with live parts e g welding current sockets is potentially fatal Follow safety instructions on the opening pages of the operating instructions Commissioning may only be carried o...

Страница 8: ...rve the operating instructions for the wire feed unit and for the power source The steps connect the intermediate tube package to the wire feed unit connect the welding torch connect the wire supply s...

Страница 9: ...ert the end of the tube package through the strain relief intermediate tube package and lock by turning to the right Insert cable plug on the control lead into the 7 pole connection socket and secure...

Страница 10: ...ecome damaged and as a consequence cause injury to persons Always position internal wire feed feet in the relevant recesses External casing frame of the wire feeds must be positioned level on the supp...

Страница 11: ...ly Insert the end of the tube package through the strain relief intermediate tube package and lock by turning to the right Insert cable plug on the control lead into the 7 pole connection socket and s...

Страница 12: ...Dual operation as the slave The following settings should be carried out in sequence on both wire feeds with compact units on the welding machine and wire feed or checked open the special parameters...

Страница 13: ...Set the wire feed control to single operation if no second wire feed is connected 6 2 Changing over between wire feeds On the welding torch of the inactive wire feed Tap torch trigger press briefly Ch...

Отзывы: