Rectifying faults
Checklist for rectifying faults
40
099-M183xB-EW501
18.7.2022
Error message
Possible cause
Remedy
E34
Electronics error
Switch the machine off and on again.
If the error persists, notify service department
E37
Temperature error
Allow the machine to cool down
E40
Motor fault
Check wire feed mechanism,
switch the machine off and on again, inform the
service department if the fault persists.
E51
Earth fault (PE error)
Connection between welding wire and machine
casing
E55
Failure of a mains phase
Switch off the machine and check the mains volt-
age
E58
Short circuit in welding circuit
Switch off the machine and check welding current
leads for correct installation, e.g. by placing the
electrode holder in an insulated position; detach
current lead from degaussing.
7.3
Checklist for rectifying faults
The correct machine equipment for the material and process gas in use is a fundamental require-
ment for perfect operation!
Legend
Symbol
Description
Fault/Cause
Remedy
Collective interference signal light illuminates
Excess temperature, welding machine
Allow the machine to cool down whilst still switched on
Welding current monitoring device triggered (stray welding currents flowing across the protective
earth). The error must be reset by switching the machine off and on again.
Welding wire is touching electrically conductive casing parts (check wire guide, has the welding
wire sprung off the wire spool?).
Check for a correct mounting of the welding lead. Fit the feeder clamp of the welding lead as
close as possible to the arc.
Excess temperature signal light illuminates
Excess temperature, welding machine
Allow the machine to cool down whilst still switched on