Design and function
Degaussing
099-002065-EW501
9.9.2019
25
5.3.2 Notes on laying power cables
Figure 5-7
• Lay power cables close together around the component.
• The greater the distance to the welding-relevant area (A), the greater the number of turns you must
select. Using the activgauss method, it is possible to increase the degaussing current as an alternative
or in addition.
Large or long workpieces
Figure 5-8
• Lay power cables close together around the component.
• Lay power cables up to the welding-relevant area, such as the sidewall of the joint.
With too little space, the turns can also be laid on top of each other. This has no significant
influence on the degaussing process.
As the distance between the individual turns (B) increases, the current must be corrected
upwards to achieve the desired result.