                          Model 072000

    

Smart Digital Humidistat

      Installation and Owner's Manual

The  072000  is  a  digital  humidifier  control 
that  can  automatically  adjust  the  indoor 
humidity  set  point  as  the  outside  air 
temperature  changes.  This  intelligent 
control  will  maintain  accurate  humidity 
levels  and  a  more  comfortable  indoor 
environment.

The  actual  indoor  relative  humidity  is 
always displayed on the LCD screen. When 
the

 

  or 

down

  keys  are  pressed,  the 

humidity set point is displayed and can be 
adjusted  using  the 

up

  and

  down

  arrow 

keys.

An outdoor temperature sensor is included, 
and  must  be  connected  in  order  to  fully 
utilize  the  features  of  the  072000.  The 
outdoor  temperature  sensor  allows  the 
humidistat  to  automatically  adjust  the 
humidity set point, to avoid condensation on 
windows. It is also a convenient way to read 
the outdoor air temperature at any time.

up

The  outdoor  sensor  is  not  required  to 
use  the  Humidistat  in  the  basic  or 
manual mode. 

The 072000 operates on 24vac, and has 
a  set  of  isolated  dry  contacts  for 
activating  the  humidifier. Terminals  are 
also  provided  for  the  Outdoor  air 
Temperature Sensor. (Part

OAS)

The  072000  can  be  installed  on  the 
return air duct or, it can be installed on an 
interior  wall  within  the  conditioned 
space.  EWC  Controls  recommends  an 
interior  wall  installation.  NOTE:  If  the 
return air duct is chosen as the location, 
the  HVAC  fan  should  be  set  to  run 
continuously,  in  order  to  obtain  an 
accurate  sampling  of  the  actual  living 
space relative humidity condition.

General Description

TECHNICAL BULLETIN

TB 213

  P/N 090375A0213   REV. E  December 5, 2006                 Copyright © 2004-2006, EWC Controls Inc.,  All Rights Reserved

RH

OD

%RH

TEMP

MAN

AUTO

MOD

E

Package includes:
1 #072000 Smart Humidistat
1 Foam Gasket
1 Mounting Template
1 Technical Bulletin #TB213
2 Mounting screws
2 Wall anchors
1 #OAS Outside Air Sensor

Your new 
Steam 
Humidifier may 
include this 
control. The 
instructions are 
included! 
Please refer to 
this Bulletin.

®

Содержание Ultra-Zone S2000

Страница 1: ...nal parts recommended 1 Water Hammer Arrester WH 100 2 Anode Z100 3 Decorative Under Duct Cover SC100 4 Gasket Material to seal flanges field provided 5 Model APD Current Sensing Switch Sail Switch or other Airflow Proving Device 6 WFA 195 Water Filter Assembly Installation Instructions Owner s Manual WATER INLET WATER LEVEL PROBE HEATER TEMPERATURE PROBE FIG 1 Fo r Re pla ce me nt Pa rts Ca ll 80...

Страница 2: ... be met you should install the unit under theductby meansof thetankflange Seepage6 If a suitable means of gravity draining the unit is not available or cannot be provided the unit will work with the drain valve electrically disconnected Call the Technical Support Hotline for Instructions It is highly recommended but not required that the use of Fiberglass duct board with this product includesan an...

Страница 3: ...difier has an integrated air proving feature that allows the user to install a sail switch and or high humidity switch in the duct and easily achieve fail safe shutdown in the event of fan blower failure This feature prevents the Steam Humidifier from operating unless adequate airflow is proven thereby avoiding a saturated duct condition WARNING It is highly recommended to use an airflow proving d...

Страница 4: ...uld read infinity no continuity when the fan blower is off 2 Turn on the fan blower at the thermostat and test for continuity across the normally open contacts with the fan blower running You should now read continuity a complete circuit when the fan blower is running 062000 Humidistat G1 R G2 H H A A S2000 S2020 Humidifier Low Voltage Terminal Block Disconnect the wires from the A terminals and c...

Страница 5: ...fier will obstruct approximately 70 square inches of duct area The tank flange is no longer a factor At 92 8 square inches the smallest duct plenum that can accommodate the Steam Humidifier mounted internally would be approximately 20 by 19 20x19 380 square inches multiplied by 25 95 square inches Steam Humidifier square inches of obstruction 92 8 square inches Up flow configuration 25 percent of ...

Страница 6: ... 7 7 2 6 C O N T R O L S I N C U L C U S L I S T E D 1 4 1 V P O W E R D R A I N F I L L H E A T E R B L O W E R T h e r m i s t o r H e a t e r W a t e r S u i t a b l e f o r R e s i d e n t i a l U s e O n l y M o d e l S 2 0 2 0 S t e a m H u m i d i f i e r 2 0 K W 2 4 0 V o l t 8 3 A m p s F o r R e p l a c e m e n t P a r t s C a l l 8 0 0 4 4 6 3 1 1 0 0 9 0 2 1 A 0 1 1 8 U S P A T E N T N...

Страница 7: ...ocationis theonlysolution Installation instructions for the 072000 model Humidistat arepackaged with the 072000 Your humidifier may include Model 062000 Humidistat Installation instructions for the 062000 model are packaged withthe062000 There are many ways to wire and control a humidifier Refer tothewiringdiagramsonpages4and7 10 SETTINGTHEHUMIDISTAT RH OD RH TEMP MAN AUTO MODE Outside Dry Bulb Te...

Страница 8: ...or the water to heat to 170 deg F If the humidistat remains closed the HEATER and BLOWER LED s will both be illuminated at the same timeandthe POWER LEDwillbeblinkingslowly E The FILL LED will illuminate and the water reservoir will refill at irregular intervals depending on the boil off rate The HEATER LED should remain illuminated unless the humidistat opens or the humidifierentersadraincycleorf...

Страница 9: ...he water line and the drain lines Store the unit in this condition for the summer orcontinuetothenextstep START UP Turn on the water supply Inspect the water connections and drainfittingsforleaks Plug in the S2000 power cord to the 120 VAC 240 VAC for S2020 groundedoutlet DO NOTuseanextensioncord 1 The green POWER light should blink rapidly until it detectsademandtohumidify thenitwillblinkslowly 2...

Страница 10: ...hedrainvalveisunpluggedor defective 7 Debris iscloggingthedrainvalveordrainline 8 Reset the unit by unplugging the power cord and re connecting Both Red ServiceLights error 3 areon constantly HEATER FAILURE This is an indication that the water temperature is not increasing or reaching the boiling point 1 Faultyheaterelementorfaultywireconnection 2 This can happen if the unit is operated without wa...

Страница 11: ... 100 Z 100 2004 2006 2120 2001 2240 2002 2008 2005 2006 2003 2007 2001 1 2 3 4 5 6 7 8 9 10 DESCRIPTION OF PART S2000 S2020 PART NO PART NO 11 2009 2009 UNDER DUCTSTEAM COVER not shown Fo r Re pla ce men t Pa rts Ca ll 800 44 6 31 10 09 02 1A 01 18 U S PATENT NUMBER 57 58 01 8 se ria l nu mbe r Ewc 385 Highway 33 Englishtown NJ 07726 CONTROLS INC U L C US LISTE D 14 1V POWER DRAIN FILL HEATER BLOW...

Страница 12: ...m e mail info ewccontrols com Tel 800 446 3110 Fax 732 446 5362 Figure 18 12 DRAIN COCK VALVE T ADAPTER 1 4 NPT OVERFLOW TUBE 50 ID x 6 LG BARBED TEE 1 4 18 NPT TO JUMPER WIRE 20GA X 1 50 LONG MOLEX PLUG BLACK WIRES 18GA X 18 LONG SOLENOID VALVE 24 60 VAC ...

Страница 13: ...nsor is not required to use the Humidistat in the basic or manual mode The 072000 operates on 24vac and has a set of isolated dry contacts for activating the humidifier Terminals are also provided for the Outdoor air Temperature Sensor Part OAS The 072000 can be installed on the return air duct or it can be installed on an interior wall within the conditioned space EWC Controls recommends an inter...

Страница 14: ... disconnected and the unit has been removed from the duct Refer to the blow up view on Page 11 Using a phillips screwdriver remove the two screws that hold the baffle plate to the tank Lift the baffle slightly back to clear the water probe and then straight up and out of the tank You can then see the round Z100 or rather what is left of it after a single season Notice the heavy scale build up on t...

Страница 15: ... The SC100 is just the latest innovation in the Ultra Zone Steam Humidifier line as we continue in our pursuit of Excellence Without Compromise EWC Controls Inc 385 Highway 33 Englishtown NJ 07726 800 446 3110 FAX 732 635 8646 E Mail info ewccontrols com P N 090376A0151 REV A SC100 PART 2009 DECORATIVE COVER S2000 S2020 STEAM HUMIDIFIER Copyright 2003 EWC Controls Inc All Rights Reserved SC100Inst...

Страница 16: ...e __________Service Performed ________________________________________________________ Date of Service __________Service Performed ________________________________________________________ Date of Service __________Service Performed ________________________________________________________ Date of Service __________Service Performed ________________________________________________________ Date of Se...

Отзывы: