background image

I N D O O R   A I R   Q U A L I T Y

HCWB3

Healthy Climate

®

By-Pass Humidifier

Bulletin No. 210543

September 2009

Model Number Identification

HCWB 3 - 17 A

Unit Type 

HCWB

 = Healthy Climate By-Pass Humidifier  

Nominal Capacity 

12 = 12  US Gallons per day 

17 = 17 US Gallons per day

Features

WARRANTY

All covered components - limited warranty for five 

years in residential applications, one year in non-

residential applications.
Refer to the Lennox Equipment Limited Warranty 

certificate included with the unit for additional details.

APPROVALS

Units are UL listed per ANSI/UL 998 and CSA C22.2 

No.104-01.

APPLICATIONS

Applicable to most forced air installations.
Installs on the supply air plenum with a by-pass duct 

from the return plenum in up-flow and horizontal 

applications. Installs on the return air plenum with a 

by-pass duct from the supply plenum in down-flow 

applications. See Typical Applications.
Provides additional humidity to the home during the 

heating season to increase comfort level.

Do not install where freezing may occur.
Humidifier, saddle valve and manual or automatic 

humidifier control (depending on model) shipped in one 

package.

Sequence of Operation

Humidifier will only operate when indoor blower is 

operating.
When the level of moisture in the return air or living 

space area drops below the set point of the humidifier 

control, the water solenoid valve opens, water flows 

into distribution tray and weeps down through the 

evaporator pad. By-pass air flows over the evaporator 

pad, increasing the humidity of the air, and then back 

into the return air stream. When the humidifier control 

is satisfied the water solenoid valve closes.

Cabinet

Rugged, corrosion resistant molded plastic.

Humidifier is shipped for left-hand by-pass duct 

connection.
For right-hand by-pass duct connection, rotate 

humidifier cabinet 180º top for bottom and relocate 

drain spud. See Installation Instructions for additional 

details.
Built-in damper included to close off bypass duct during 

summer cooling operation.

E N G I N E E R I N G   D ATA

Series

Controls

 

(blank) - Manual Humidistat

 

A = Automatic Humidifier Control

Automatic Humidifier Control

 

(furnished with “A” Models)

Manual Humidistat

 

(furnished with

 

standard Models)

Содержание HCWB3

Страница 1: ...nstall where freezing may occur Humidifier saddle valve and manual or automatic humidifier control depending on model shipped in one package Sequence of Operation Humidifier will only operate when indoor blower is operating When the level of moisture in the return air or living space area drops below the set point of the humidifier control the water solenoid valve opens water flows into distributi...

Страница 2: ...ovable for cleaning or replacement Evaporator Media Pad Provides large evaporation capacity Pad and support frame removable for cleaning or replacement Annual pad replacement recommended Saddle Valve All necessary fittings furnished as standard equipment Field installs in the water supply line OPTIONAL ACCESSORIES Installation Kit Canada Only Kit contains 6 in dia duct ring flange 2 5 ft of 6 in d...

Страница 3: ... 8 156 DIA BY PASS DUCT CONNECTION B OPENING 1 AIR FLOW NOTES By pass duct air flow direction is dependent on application For downflow applications air flow is to the humidifier from the supply air duct 1 Left hand air inlet outlet shown For right hand inlet outlet rotate humidifier cabinet 180º top for bottom and relocate drain to alternate location on cabinet See Installation Instructions for ad...

Страница 4: ... VOLUME OF HOME Model No Type of Home 8 Foot Ceiling 9 Foot Ceiling 10 Foot Ceiling Home Area sq ft Home Area sq ft Home Area sq ft HCWB3 12 HCWB3 12A Loose 750 666 600 Average 1500 1350 1200 Tight 3000 2700 2400 HCWB3 17 HCWB3 17A Loose 1000 888 800 Average 2000 1800 1600 Tight 4000 3600 3200 NOTES Loose Home Two Air Change Rates per hour Typically loose in construction and is over 20 years old N...