Reminders
Once a reminder has been turned on and set, the elapsed time can be
checked by navigating to its tech setup step. The elapsed time will then
appear in the text field. It can also be reset at that time by holding down
the Set Time/Next Step button for 3 seconds. Resetting an expired
reminder can be done without entering tech setup, by holding down
the Set Time/Next Step button for 3 seconds from the home screen.
A Note about IAQ Mode
This programmable/selectable mode will operate the fan 1-4 cycles per
hour, 1-45 minutes per cycle. Once programmed in tech setup, to enable
this mode select “IAQ” with the fan key. Disable this mode by selecting
“ON” or “AUTO” with the fan key.
Enables a reminder for the user to
change the humidity pad.
Humidity Pad
Reminder
Enables a reminder for the user to
change the UV light bulb.
UV Lamp
Reminder
OFF
Use the or key to
select OFF, 600, 1000, 1500,
or 2000. These represent
hours of heat operation.
Enables a reminder for the user
to change the PHI Cell after
25,000 hrs.
IAQ Cell
Reminder
Use the or key to
select OFF, or 250 (stands for
25,000 hours).
OFF
HUM PAD 2000
OFF
UVLAMP 00000
Use the or key to
select OFF, 1YEAR, 2YEAR.
OFF
OFF
Tech Setup Steps
Adjustment Options
Default
LCD Will Show
Technician Setup Menu
WIFI Technician Setup Menu
This feature allows you to set a
minimum cooling setpoint limit.
The setpoint temperature cannot
be lowered below this value.
This feature allows you to set a
maximum heating setpoint limit.
The setpoint temperature cannot
be raised above this value.
Heating
Temperature
Setpoint
Limit
Use the or key to
select the maximum heat
setpoint.
This feature allows you to display
temperatures in either Fahrenheit
or Celsius.
˚F or ˚C
˚F
˚F for Fahrenheit
˚C for Celsius
You can select either a 12 or 24
hour clock setting.
12 or 24
Hour Clock
Select GAS for systems that
control the fan during a call for
heat. Select ELEC to have the
thermostat control the fan during
a call for heat.
Fan
Operation
90
78
12H
12
HOUR CLOCK
GAS
ELE
Cooling
Temperature
Setpoint
Limit
Use the or key to
select the minimum cool
setpoint.
44
44˚F
90˚F
HE
CO
O
F
Use the or key to
select 12 or 24 hour clock.
GAS or ELEC
Note: This step will not show
if set for heat pump.
This feature will start heating
early to bring the building
temperature to its programmed
setpoint by the beginning of the
WAKE, OCCUPIED time period.
Morning
Recovery
OFF
Use the or key to
turn on or off. It will default
to electric.
You can configure this thermostat
to have a 7 day program, a
5+1+1 program or as
nonprogrammable.
Program
Options
5d
Use the or key to
select
7d
for 7 day,
5d
for
5+1+1, or
0d
for
nonprogrammable.
5d
The display light can be
configured to operate 3 differet
ways. To come on only when the
light key is pressed, when any
key is pressed, or stay on ALL of
the time.
The pre-occupancy fan settings
will energize the fan before
the occupied time to provide
ventilation prior to scheduled
occupancy.
This feature only shows if the
technician setup step for time
periods is set to 2.
Pre-Occupancy
Fan
You can select the
pre-occupancy fan from OFF,
1, 2, or 3 hours.
If 1, 2, or 3 is selected, the
fan will turn on that many
hours prior to the scheduled
occupied time period.
Tech Setup Steps
Allows you to put your phone
number in the display.
You can choose ON or OFF.
Contractor
Call Number
If selected ON, you will
see the input screen after
pressing
NEXT STEP
.
Use the or key to
select the desired number
and the
FAN
or
SYSTEM
key
to move from one character
to another. See note below
for operation.
Adjustment Options
Default
LCD Will Show
When any key is pressed an
audible beep will sound.
You can choose ON or OFF.
Beep
PRE
OCCUPY
FAN
Display Light
‘OFF’ - Only light key ON
‘AUTO’ - Any key ON
‘ON’ - Always ON
Time Periods
You can configure this thermostat
to have 2 or 4 programmable time
periods per day. 4 time periods
are Wake, Leave, Return & Sleep.
2 Time periods are Occupied and
Unoccupied.
Use the or key to
select
4
or
2
time periods
per day.
4
AUTO
OFF
dL
If ON is selected the beep
will sound.
If OFF is selected there is no
sound.
4
AUTO
OFF
ON
b
Tech Setup Steps
Adjustment Options
Default
LCD Will Show
Contractor Call Number Note
If contractor call number is selected ON, the phone number entered will
show in the display if there has been a continuous call for heating or
cooling for 24 hours or if the light button is held down for 3 seconds. To
remove the phone number from the display, hold the light button down
for 3 seconds.
Technician Setup Menu
Technician Setup Menu
OFF
OFF
OFF
This step allows you to reset
the thermostat to connect to a
different WIFI network.
Provisioning
Reset
Press YES to reset.
This step resets all WIFI settings
to factory default.
Factory
Default
Reset
WIFI Module
Reset
This step resets the
communication of the WIFI
module.
This step shows the version of
firmware that is installed on the
thermostat.
Firmware
Version
Press NEXT button to move to
next step. Press DONE button
to exit. Press and hold TECH
button to enter ADVANCED
TECH STEPS.
SSID
Number
This step shows the SSID number
of the thermostat. (Network it is
connected to)
Press NEXT button to move to
next step. Press DONE button
to exit. Press and hold TECH
button to enter ADVANCED
TECH STEPS.
WIFI Tech Setup Steps
Adjustment Options
Default
LCD Will Show
These steps/options are only used for trouble shooting, re-setting or
restoring to default the WIFI settings of the thermostat. They are not
needed for installation or initial setup.
1. Press
MENU
button.
2. Press
WIFI
button. This enters the 2 informational steps.
3. At this point press and hold
TECH
to enter advanced settings.
4. Press
NEXT
to move from one to the other.
5. Press
DONE
or
EXIT
when finished.
WIFI Advanced Tech Setup Steps
Adjustment Options
Default
LCD Will Show
Press YES to reset.
Press YES to reset.
RESET
WIFI MODULE
RESET
PROVISIONING
RESET
TO DEFAULT