![EWC Controls EWT-3102 Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/ewc-controls/ewt-3102/ewt-3102_user-manual_2447872093.webp)
EWT-3102 / EWT-3103 Touchscreen Programmable Thermostat
OPERATION IN EMERGENCY HEAT MODE
The balance point (outside) temperature is
not used in the Emergency heat mode.
When the thermostat is moved to the
Emergency Heat position, the compressor
is locked out. The first stage of heat is
whatever is connected to the E terminal.
The second stage of heat is what is
connected to the Aux. terminal. Often there
is only one source of non-compressor heat
and the E terminal is jumped to the Aux.
terminal.
Heat Pump with Electric Auxiliary
(Backup) Heat and Outdoor
Temperature Sensor
1. Choose correct heat pump application in
Installer Setup Number 0170.
2. Choose Electric as
Auxiliary (Backup)
Heat Source
in Installer Setup Number
0200.
3. Choose
Outdoor Temperature Sensor
for Control Option
in Installer Setup
Number 0340.
4. Choose
Compressor Lockout
Temperature
in Installer Setup Number
0350.
5. Choose
Auxiliary Lockout
Temperature
in Installer Setup Number
0360.
NOTE: There is a 5°F deadband between
the Compressor and Auxiliary Heat Lockout.
92