![EWC Controls EWT-3102 Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/ewc-controls/ewt-3102/ewt-3102_user-manual_2447872058.webp)
EWT-3102 / EWT-3103 Touchscreen Programmable Thermostat
Table 3.Installer Setup Menu. (CONTINUES)
Installer Setup
Number
Installer Setup
Name
Settings Notes
0650
Extended Fan On Time
Heat
0-no extended fan operation after call for
heat ends.
90-fan operation is extended 90 seconds
after call for heat ends.
Not shown if fan operation is
set to fossil fuel or in Cool Only
Systems.
0660
Extended Fan On Time
Cool
0-no extended fan operation after call for cool
ends.
90-fan operation is extended 90 seconds
after call for cool ends.
Not shown in Heat Only
Systems.
0670 Keypad
Lockout
0-unlocked keypad.
1-partially locked keypad.
2-fully locked keypad.
Unlocked all functions are
available. Partially locked only.
Temperature up and down
keys and ability to enter and
modify Installer Setup mode
are available.
Fully locked only ability to
enter and modify-Installer
Setup mode are available.
0680
Temperature Control in
Heat
1-less aggressive temperature control (could
cause temperature undershoot).
2-Standard temperature control in heating
(factory setting).
3-more aggressive temperature control
(could cause temperature overshoot).
Applies to recovery ramp and
use of auxiliary heat during
recovery.
Choose 1 if getting
temperature overshoot.
Choose 3 if getting
temperature undershoot.
57