![EWC Controls EWT-3102 Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/ewc-controls/ewt-3102/ewt-3102_user-manual_2447872054.webp)
EWT-3102 / EWT-3103 Touchscreen Programmable Thermostat
Table 3.Installer Setup Menu. (CONTINUES)
Installer Setup
Number
Installer Setup
Name
Settings Notes
0270
Cycles per hour (cph)
for Emer
3-3 cph for hot water systems and high
efficiency (90% or better) furnaces.
5-5 cph for standard fossil fuel forced air
(less than 90% efficient or better) systems.
9-9 cph for electric strip heat for heat pumps.
Only shown if 2H/1C or 3H/2C
heat pump is selected.
0280 Backlight
0-Backlight function disable.
1-Backlight function enable.
.
0300 Changeover
0-manual changeover (factory setting).
1-auto changeover.
0310 Deadband
Heating and cooling set-points can be set no
closer than chosen value:
2-2°F (1.5°C)
3-3°F (2°C)
4-4°F (2.5°C)
5-5°F (3°C)
6-6°F (3.5°C)
7-7°F (4°C)
8-8°F (4.5°C)
9-9°F (5°C)
Shown only if automatic
changeover is selected.
0320
Temperature Indication
Scale
0-fahrenheit temperature display (factory
setting).
1-celsius temperature display.
When it is changed, the
schedule need to be
reprogrammed.
53