EVVO 20000TLG23P~EVVO 33000TLG23P
EVVO 20000TLG23P~EVVO 33000TLG23P
23
24
Step 4
Putting the inverter hook on the rear panel.
Step 5
Using an M6 screw back and inverter bottom fastening, to ensure safety.
Step 6
Putting the rear panel and inverter to lock together, In order to ensure the safety (the
user can select lock according to the actual situation).
4
Electrical Connections
Outlines of this chapter
This topic describes the inverter electrical connections. Read this part carefully before
connecting cables.
Step 4
Step 5
Step 6
NOTE:
Before performing electrical connections, ensure that the DC switch is OFF. Since the
stored electrical charge remains in a capacitor long after the DC switch is turned OFF.
So,
it’s necessary to wait for at least 5 minutes for the capacitor to be electrically
discharged.
Installation and maintenance of inverter, must be operated by professional
electrical engineer.
Attention
PV modules generate electric energy when it exposed to sunlight and can create
an electrical shock hazard. Therefore, before connecting DC input power cable,
cover PV modules using opaque cloth.
Danger
The inverter has 2 MPP trackers, all PV modules connected to the same MPPT
should have similar rated electrical characteristics (including Isc, Voc, Im, Vm,
Pm and temperature coefficients), have the same number of series connected PV
modules and be all in the same orientation (azimuth and tilt angle).
Note
4.1
Electrical connection
This topic describes the electrical connection process.
4.2
Connecting PGND Cables
Connect inverter to the grounding electrode using protection ground (PGND) cables for
grounding purposes.
4.3
Connecting AC Output Power Cables
Connect inverter to the AC power distribution frame (PDF) or electrical grid using AC output
power cables after obtaining approval from local electrical grid operator.
4.4
Connecting Communication Cables
This topic describes the functions of WIFI and RS485 ports and the method of connecting
WIFI and RS485 communication cables.
4.5
Connecting DC Input Power Cables
Connect inverter to PV arrays using DC input power cables.
4.6
Safety check
Before start the inverter, comply with the safety precautions and check AC
、