User Manual | move&charge | coffee&charge | 46
ERROR 0040000000
EV CAN VOLTAGE RANGE
Check vehicle status
Vehicle’s voltage range exceeds charger’s
›› Check vehicle.
ERROR 0080000000
EV CAN SHIFT LEVER
Vehicle not in P
Message from vehicle: gear lever not in
«P»
›› Put gear lever into «P»;
consult vehicle’s user manual.
ERROR 0100000000
TIMEOUT SHUTDOWN
›› Disconnect all plugs from vehicle; dis-
connect device from grid; wait 30 sec-
onds; reconnect.
If the same error occurs again: call service
ERROR 0200000000
UNEXP SESSION STOP
EV Sequence Error
›› Check vehicle.
ERROR 0400000000
PP RESISTOR WRONG
Check cable
›› Check charging cable; Replace calbe if
needed.
ERROR 0800000000
OCPP TIMEOUT
No connection...
›› Disconnect all plugs from vehicle; dis-
connect device from grid; wait 30 sec-
onds; reconnect.
If the same error occurs again: call service