43
ERROR 0000000200
HV UNDER OVERVOLTAGE
High Voltage system under or over voltage
›› Disconnect device from grid; call service.
ERROR 0000000400
RCDOCP POWER CIRCUIT
Switch on RCDOCP
Power unit RCD/OCP tripped
›› Check if charging device has optical
damages;
If no damages are visible reactivate
RCD/OCP
ERROR 0000000800
RCDOCP CTRL CIRCUIT
Switch on RCDOCP
Control circuit RCD/OCP tripped
›› Check if charging device has optical
damages;
If no damages are visible reactivate
RCD/OCP
ERROR 0000001000
SIGNAL SUPPLY EV
Error signal supply on vehicle side
›› Disconnect all plugs from vehicle; dis-
connect device from grid; wait 30 sec-
onds; reconnect.
If the same error occurs again: call service
ERROR 0000002000
SIGNAL SUPPLY CONTRL
Error signal supply charger
›› Disconnect all plugs from vehicle; dis-
connect device from grid; wait 30 sec-
onds; reconnect.
If the same error occurs again: call service
ERROR 0000004000
CONTROL MALFUNCTION
Internal error in communication with power
unit
›› Disconnect all plugs from vehicle; dis-
connect device from grid; wait 30 sec-
onds; reconnect.
If the same error occurs again: call service
Содержание coffee&charge 3in1
Страница 1: ...User Manual move charge ...
Страница 18: ...17 Identifcation Acceptance Unidentified user Connecting to server Card not valid Checking user ID ...
Страница 41: ...User Manual move charge coffee charge 40 ...
Страница 49: ...User Manual move charge coffee charge 48 3 Turn the FI LS switch back on ...
Страница 54: ...53 Certificates ...
Страница 55: ...User Manual move charge coffee charge 54 ...
Страница 57: ......