XT2+ Series DISK RECORDER - Version 10.05 - Hardware Technical Reference Manual
Issue
10.05.A
EVS Broadcast Equipment SA – July 2011
9
1.6.5
P
OWER
S
UPPLY
The XT3 server is fitted with two auto switching and hot-swappable power
supplies.
Connection to supply: Pluggable equipment Type A (EN60950 §1.2.5): Equipment
which is intended for connection to the building power supply wiring via a non-
industrial plug and socket-outlet or a non-industrial appliance coupler or both.
Correct mains polarity must always be observed. Do not use reversible power
plugs with this equipment.
Class of equipment: Class 1 equipment (EN60950 § 1.2.5): electric shock
protection by basic insulation and protective earth.
Rated voltage: 115 to 240Vac (single phase)
Rated frequency: 47-63 Hz
Related Current: 8 A (100 to 120 Vac range) 4 A (220 to 240 Vac range)
Input connector: CEE22/IEC 320 3-pin male receptacle
Important
The protective earth must be connected to the ground before powering
up the unit.
E
NVIRONMENTAL
C
ONDITIONS
Temperature: 10°C to + 50°C (50°F to 122°F) ambient with free air flow
Relative humidity: 0% to 90% (non-condensing)
Cooling requirements: Forced air cooling air flow from front to back
Handling/movement: Designed for fixed use when in operation
Storage and transportation temperature: 0°C to +70°C (32°F to 158°F)
Storage and transportation relative humidity: 0% to 90% (non-condensing)
S
ECONDARY
P
OWER
S
UPPLY
The secondary hot-swappable power supply should be connected to mains to allow
automatic power switching to the second power supply should the first one fail.
G
ROUNDING
Ensure the disk recorder unit is properly grounded at all times to avoid electrical
shock hazard.
Содержание XT2+
Страница 1: ...Technical Reference Hardware Version 10 05 July 2011 Production Playout Server ...
Страница 2: ......
Страница 4: ......