XT2+ Series DISK RECORDER - Version 10.05 - Hardware Technical Reference Manual
Issue
10.05.A
EVS Broadcast Equipment SA – July 2011
71
LED
S ON
I
NTERNAL
A
RRAY
LEDs 1 to 6 are used in case of one internal array of 6 disks.
LEDs 7 to 12 are used for the upper series of disks in case of one internal array of
2x6 disks.
LEDs correspond to the disks as schematized as followed:
upper 7
12
lower
1
6
upper 8
9
10
11
lower
2
3
4
5
Disk LEDs
off
the corresponding disk is not started (not spinning)
on, fast blinking
(green)
the corresponding disk is starting (spinning)
on, steady (green)
the corresponding disk is started and used in the RAID
array
on, slowly blinking
(green)
the corresponding disk is started but not used in the RAID
array
STS
on (green)
when RCTL RAID controller is properly booted.
ERR
lights red
when errors occur during the data transfer between the RAID
controller and the disks