EVS Broadcast Equipment SA
15
SFP1-Type
This status item displays the type name/number SFP I/O module A.
SFP2-Vendor
This status item displays the name of the SFP I/O module B.
SFP2-Type
This status item displays the type name/number SFP I/O module B.
SFP1-Temp-Stat
These indicate whether the temperature of SFP input/output module
A is
Too_High
,
High
,
OK
,
Low
or
Too_Low
. Can also be
NA
in case Temperature monitoring is not available or the module is not
inserted.
SFP1-Volt-Stat
These indicate whether the voltage usage of SFP input/output
module A is
Too_High
,
High
,
OK
,
Low
or
Too_Low
. Can also
be
NA
in case Voltage monitoring is not available or the module is
not inserted.
Port1/2-Enabled
These item indicate whether the corresponding output port on SFP
output module A is
enabled
,
disabled
or
NA
(Not available,
when no input signal is available or an input module is inserted.)
Port1/2-Power
These status items indicate the current transmitter power of the
specified port on SFP output module A between 0mW and 6.55mW.
When a receiver is installed or no SFP module is inserted this value
is 0.
Port1/2-Pow-Stat
These indicate whether the output power of the specified port on
SFP output module A is
Too_High
,
High
,
OK
,
Low
or
Too_Low
. Can also be
NA
in case of an input module or no
module is inserted.
Port1/2-Bias
These status items indicate the current laser bias of the specified
port on SFP module A is between 0mA and 300mA. When there is
a non fiber SFP or an input module is inserted, this value will be 0.
Port1/2-Bias-Stat
These indicate whether the laser bias of the specified port on SFP
output module A is
Too_High
,
High
,
OK
,
Low
or
Too_Low
.
Can also be
NA
in case laser bias monitoring is not available or no
output module is inserted.
Port1/2-
Wavelength
Indicates the current wave length of the corresponding output port
on the SFP output module A between 0nm and 2000nm. When there
is a non fiber SFP or RX module installed, this value will be 0.
SFP2-Temp-Stat
These indicate whether the temperature of SFP input/output module
B is
Too_High
,
High
,
OK
,
Low
or
Too_Low
. Can also be
NA
in
Содержание SYNAPSE GDR416