INSTALLATION AND CONFIGURATION MANUAL
GDR416
14
6 Status Menu
Introduction
The status menu indicates the current status of each item listed
below. There are no defaults for status indicators. Status depends of
input signals being present or not.
SDI-Input_A
This status item indicates the presence of a valid SDI signal on
input A.
SDI_Input_A
indicates if an input signal is
Present
,
Loss
or
NA
.
PLL-rate_A
PLL_rate_A
indicates the rate at which the PLL of input A is
locked when
PLL_Set_A
is set to
auto
. The range of locking
rates is as follows:
270
Mb/s,
1485
Mb/s, and
2970
Mb/s
SDI-Input_B
This status item indicates the presence of a valid SDI signal on
input B.
SDI_Input_B
indicates if an input signal is
Present
,
Loss
or
NA.
PLL-rate_B
PLL_rate_B
indicates the rate at which the PLL of input B is
locked when
PLL_Set_B
is set to
auto
.
SDI-Input_C
This status item indicates the presence of a valid SDI signal on
input C.
SDI_Input_C
indicates if an input signal is
Present
,
Loss
or
NA.
PLL-rate_C
PLL_rate_C
indicates the rate at which the PLL of input C is
locked when
PLL_Set_C
is set to
auto
.
SDI-Input_D
This status item indicates the presence of a valid SDI signal on
input D.
SDI_Input_D
indicates if an input signal is
Present
,
Loss
or
NA.
PLL-rate_D
PLL_rate_D
indicates the rate at which the PLL of input D is
locked when
PLL_Set_D
is set to
auto
.
SFP1-Vendor
This status item displays the name of the SFP I/O module A.
Содержание SYNAPSE GDR416