Temperature Protection 

The DNA 200 directly measures and limits the temperature of the heating coil during operation. 

By preventing the coil from becoming too hot regardless of fluid, wicking or airflow, a variety of 
undesirable situations can be prevented. For example, appropriate temperature settings will prevent the 
wicking material from charring, which compromises taste and introduces unintended chemicals into the 
vapor. Appropriate temperature settings will also reduce the breakdown of flavoring and base liquid 
components, which could impact taste or safety.  

 

Evolv’s Temperature Protection Technology requires a heating coil made from Nickel 200 alloy, 

rather than Nickel Chromium or Kanthal alloys. Nickel 200 is commercially pure nickel. It is often sold in 
vapor shops and online as “non-resistance wire.” If the temperature reaches the maximum value, the 
wattage applied to the atomizer coil is reduced to prevent overheating. Please note that the 
temperature reading is the average temperature of the atomizer coil, and care should be taken to 
construct the heating coil so that the temperature is uniform, without hot or cold spots. 

 

Because wattage, not temperature controls vapor volume, large vapor volumes can be produced 

without unnecessarily high temperatures. Temperature Protection is most helpful if the atomizer begins 
to dry out, the user pauses during a puff, the beginning or end of the puff, or if the wattage setting is 
inappropriate for the attached atomizer.  

 

In normal operation, when the device is not firing the maximum temperature setting is 

displayed on the screen. When the device is firing, the actual average temperature of the coil is 
displayed on the screen.  

 

By default, the Temperature Protection setting is 450° Fahrenheit. To change the limit  

1)

 

Lock the device by pressing the Fire button five times.  

2)

 

Hold down the UP and DOWN adjust buttons for two seconds. 

 

3)

 

After two seconds, the maximum temperature will be displayed, and the UP and DOWN buttons 
should be released. 

 

4)

 

Use the UP and DOWN buttons to adjust the maximum temperature

 

5)

 

When the display shows the desired maximum temperature, press the Fire button to exit 
temperature adjust mode. 

 

 
The maximum temperature is adjustable between 200° Fahrenheit and 600° Fahrenheit. To 

disable the temperature protection entirely, adjust the limit up to 600 degrees, then press the UP 
button one additional time. The temperature limit will read OFF.  

 
To switch to Celsius temperature, adjust temperature down to 200° Fahrenheit, then press the 

DOWN one button one additional time. The temperature will switch to reading and adjusting in Celsius.  

 

Preheat 

 

When the DNA 200 is used with a temperature sensing atomizer, an additional feature called 

Preheat is activated. No vapor is produced when the temperature is below the boiling point of the 
liquid. Preheat applies extra power until the heating coil is up to operating temperature to shorten the 

Содержание DNA 200

Страница 1: ...g and integrated balance charger The USB port and Evolv s EScribe software can be used to customize or monitor the user experience It is the most advanced personal vaporizer controller ever made Specifications Minimum Typical Max Output Power 1 Watt 200 Watts Output Voltage 1 Volt 9 0 Volts Output Current continuous 50 0 Amps Output Current instantaneous peak 55 0 Amps Atomizer Resistance temperat...

Страница 2: ...3 Preheat 3 Attaching a New Atomizer 4 Operation 5 Display 5 Temperature Protected Error Bookmark not defined Non temperature Protected Error Bookmark not defined Modes 6 Error Messages 7 Auto power down 7 Pinout 12 Wiring 13 Recommended wire sizes 13 External component recommendations 13 Mounting 14 Mechanical Dimensions 15 ...

Страница 3: ...pauses during a puff the beginning or end of the puff or if the wattage setting is inappropriate for the attached atomizer In normal operation when the device is not firing the maximum temperature setting is displayed on the screen When the device is firing the actual average temperature of the coil is displayed on the screen By default the Temperature Protection setting is 450 Fahrenheit To chang...

Страница 4: ... new atomizers that have cooled to room temperature to the device If a new atomizer is attached to the DNA 200 before it has cooled down the temperature may read and protect incorrectly until the new atomizer cools When you connect a new atomizer or disconnect and reconnect your existing atomizer the DNA 200 will prompt you to confirm this change When you fire the first time before activating the ...

Страница 5: ...acement is possible It is also possible to order screens with custom length and shape flexible cables allowing screen placement anywhere in the device Please use caution when handling the screen and design the device so that the cable will be secured or strain relieved in operation Watt setting The power level currently set on the DNA 200 Battery indicator The current state of charge of the batter...

Страница 6: ... power setting This mode prevents accidental power level changes due to the buttons being pressed while in a pocket To exit Power Locked mode hold the up and down buttons for two seconds Resistance lock The DNA 200 relies on the cold resistance of the atomizer to measure temperature accurately If the connection is not stable or if you find the measured resistance drifts with time it may be desirab...

Страница 7: ... resistance of the atomizer coil is too high for the current wattage setting If this happens the DNA 200 will continue to fire but will not be able to provide the desired wattage The Ohms Too High message will continue to flash for a few seconds after the end of puff Ohms Too Low The resistance of the atomizer coil is too low for the current wattage setting If this happens the DNA200 will continue...

Страница 8: ...tly and stop firing the atomizer when any of the cells reaches the cutoff voltage The DNA 200 uses the battery pack taps to monitor each cell Cell Balancer During charging is vital that none of the batteries charge beyond 4 2 volts per cell If one of the cells in the battery has more charge than the others its voltage will be higher During charging the DNA 200 will turn on a balancer to charge tha...

Страница 9: ...ad the settings presently on your device to Escribe After you make changes press the Upload Settings to Device to save the new settings to the device Atomizer Tab Battery Tab It is important to set the Capacity setting for the battery to the proper value for your battery The DNA 200 measures the energy put into the battery while charging and drawn from the battery while firing in order to know the...

Страница 10: ...cs of the screen and also to change or replace any of the status and error messages with inages Images must be 128 x 32 pixel monochrome bitmaps Research Tab The Research tab is primarily for data logging or restricting the device for use in research Information Tab ...

Страница 11: ...nformation tab is designed to look at what the DNA 200 is doing in real time Analyze will measure the atomizer like a milli ohm meter Monitor will look at the inputs and outputs of the DNA 200 as you use it ...

Страница 12: ...r up button 5 Down Positive side of the power down button 6 Down Negative side of the power down button GND GND Power output GND is the ground return for the atomizer It is connected internally to B There are three ground lugs and one ground pad B B Positive battery terminal B B Negative battery terminal Internally connected to Gnd Tap Tap Positive battery terminal Larger terminal is the main powe...

Страница 13: ...nterface However it does support the use of external interface components if desired Fire button Use a momentary on normally open type switch or button A standard pushbutton switch is appropriate The switch is a logic function all power switching is handled with transistors inside the DNA module so the switch does not need to be rated for power A waterproof or processed sealed switch is recommende...

Страница 14: ...s There is an extended mounting pad of 125 diameter around each These holes are electrically connected to each other and to ground With careful design the mounting pads can be used to ground the chassis to the DNA 200 and pass the output current through chassis to the connector However if using this method ensure that the PCB remains in good contact with the board at all times Split lock washers a...

Страница 15: ...Mechanical Dimensions Evolv has 3D models of the DNA 200 available on their website in IGES STL and Solidworks format ...

Отзывы: