Evolv DNA 200 

 

200 Watt Variable Power Module with Temperature Protection and USB 

Preliminary Datasheet 

The DNA 200 is a power regulated digital switch-mode DC-DC converter for personal vaporizers. 

It features Evolv’s patented Wattage Control, Temperature Protection, Preheat, Digital User Controls, 
OLED Screen, Onboard Buttons and Synchronous Rectification for maximum battery life and minimal 
heat generation. The DNA 200 runs from a 3 cell lithium polymer battery, and features cell-by-cell 
battery monitoring and integrated balance charger. The USB port and Evolv’s EScribe software can be 
used to customize or monitor the user experience. It is the most advanced personal vaporizer controller 
ever made.  

Specifications 

 

Minimum 

Typical 

Max 

Output Power 

1 Watt 

 

200 Watts 

Output Voltage 

1 Volt 

 

9.0 Volts 

Output Current, continuous 

 

 

50.0 Amps 

Output Current, instantaneous peak 

 

 

55.0 Amps 

Atomizer Resistance, temperature sensing wire, cold 

.08 Ohm 

.4 Ohm 

1.0 Ohm 

Atomizer Resistance, kanthal wire 

.08 Ohm 

.7 Ohm 

2.0 Ohms 

Temperature Limit 

200

°

450

°

600

°

Input Voltage 

9.0 Volts 

11.1 Volts 

12.6 Volts 

Input Current 

.5 Amps 

9.0 Amps 

23.0 Amps 

Screen On Current 

 

18mA 

 

Quiescent Current 

 

4.5 mA 

 

Power Down Current 

 

 

5uA 

Efficiency 

 

97% 

 

 

Содержание DNA 200

Страница 1: ...g and integrated balance charger The USB port and Evolv s EScribe software can be used to customize or monitor the user experience It is the most advanced personal vaporizer controller ever made Specifications Minimum Typical Max Output Power 1 Watt 200 Watts Output Voltage 1 Volt 9 0 Volts Output Current continuous 50 0 Amps Output Current instantaneous peak 55 0 Amps Atomizer Resistance temperat...

Страница 2: ...3 Preheat 3 Attaching a New Atomizer 4 Operation 5 Display 5 Temperature Protected Error Bookmark not defined Non temperature Protected Error Bookmark not defined Modes 6 Error Messages 7 Auto power down 7 Pinout 12 Wiring 13 Recommended wire sizes 13 External component recommendations 13 Mounting 14 Mechanical Dimensions 15 ...

Страница 3: ...pauses during a puff the beginning or end of the puff or if the wattage setting is inappropriate for the attached atomizer In normal operation when the device is not firing the maximum temperature setting is displayed on the screen When the device is firing the actual average temperature of the coil is displayed on the screen By default the Temperature Protection setting is 450 Fahrenheit To chang...

Страница 4: ... new atomizers that have cooled to room temperature to the device If a new atomizer is attached to the DNA 200 before it has cooled down the temperature may read and protect incorrectly until the new atomizer cools When you connect a new atomizer or disconnect and reconnect your existing atomizer the DNA 200 will prompt you to confirm this change When you fire the first time before activating the ...

Страница 5: ...acement is possible It is also possible to order screens with custom length and shape flexible cables allowing screen placement anywhere in the device Please use caution when handling the screen and design the device so that the cable will be secured or strain relieved in operation Watt setting The power level currently set on the DNA 200 Battery indicator The current state of charge of the batter...

Страница 6: ... power setting This mode prevents accidental power level changes due to the buttons being pressed while in a pocket To exit Power Locked mode hold the up and down buttons for two seconds Resistance lock The DNA 200 relies on the cold resistance of the atomizer to measure temperature accurately If the connection is not stable or if you find the measured resistance drifts with time it may be desirab...

Страница 7: ... resistance of the atomizer coil is too high for the current wattage setting If this happens the DNA 200 will continue to fire but will not be able to provide the desired wattage The Ohms Too High message will continue to flash for a few seconds after the end of puff Ohms Too Low The resistance of the atomizer coil is too low for the current wattage setting If this happens the DNA200 will continue...

Страница 8: ...tly and stop firing the atomizer when any of the cells reaches the cutoff voltage The DNA 200 uses the battery pack taps to monitor each cell Cell Balancer During charging is vital that none of the batteries charge beyond 4 2 volts per cell If one of the cells in the battery has more charge than the others its voltage will be higher During charging the DNA 200 will turn on a balancer to charge tha...

Страница 9: ...ad the settings presently on your device to Escribe After you make changes press the Upload Settings to Device to save the new settings to the device Atomizer Tab Battery Tab It is important to set the Capacity setting for the battery to the proper value for your battery The DNA 200 measures the energy put into the battery while charging and drawn from the battery while firing in order to know the...

Страница 10: ...cs of the screen and also to change or replace any of the status and error messages with inages Images must be 128 x 32 pixel monochrome bitmaps Research Tab The Research tab is primarily for data logging or restricting the device for use in research Information Tab ...

Страница 11: ...nformation tab is designed to look at what the DNA 200 is doing in real time Analyze will measure the atomizer like a milli ohm meter Monitor will look at the inputs and outputs of the DNA 200 as you use it ...

Страница 12: ...r up button 5 Down Positive side of the power down button 6 Down Negative side of the power down button GND GND Power output GND is the ground return for the atomizer It is connected internally to B There are three ground lugs and one ground pad B B Positive battery terminal B B Negative battery terminal Internally connected to Gnd Tap Tap Positive battery terminal Larger terminal is the main powe...

Страница 13: ...nterface However it does support the use of external interface components if desired Fire button Use a momentary on normally open type switch or button A standard pushbutton switch is appropriate The switch is a logic function all power switching is handled with transistors inside the DNA module so the switch does not need to be rated for power A waterproof or processed sealed switch is recommende...

Страница 14: ...s There is an extended mounting pad of 125 diameter around each These holes are electrically connected to each other and to ground With careful design the mounting pads can be used to ground the chassis to the DNA 200 and pass the output current through chassis to the connector However if using this method ensure that the PCB remains in good contact with the board at all times Split lock washers a...

Страница 15: ...Mechanical Dimensions Evolv has 3D models of the DNA 200 available on their website in IGES STL and Solidworks format ...

Отзывы: