3.0 INTRODUCTION
3.1 Safety and Caution Notes
Caution Symbol
Anytime this symbol is displayed, special note should be made to observe the care of
this particular function.
WARNING Risk of electrical shock!
The EVOLUTION Dog Wash is powered with an electrical
minimum of 120 Volts AC, 50/60 Hz / 30 amps. A dedicated 30-amp circuit
wired to the unit at the provided attach point inside the main cabinet. A qualified electrician
should only make this connection. All local codes should be followed as well at National
Electrical Code (NEC). Branch circuit protection is provided on the unit meeting or exceeding
UL1077 and/or UL489 ratings. This unit is supplied with a grounding source that should have its
integrity maintained. To reduce the risk of shock, be certain that it is connected only to a
properly grounded, grounding type buss with ratings conforming to NEC codes. Prior to any
maintenance on the unit, disconnect the unit from the electrical power source. Failure to
comply with the previous statement may void the EVOLUTION Dog Wash warranty.
Plumbing Precautions
The EVOLUTION Dog Wash requires a minimum of 20 PSI and maximum of 60 PSI at 2.0 gpm of
water flow for proper operation. Failure to provide the requirements may cause the unit to not
perform as designed. To ensure a safe installation, all plumbing connections should be made by
a qualified, licensed plumber familiar with local and national plumbing code. Any and all
exposed plumbing connections should be weather proofed to prevent damage to the plumbing
and unit. The EVOLUTION Dog Wash Company is not responsible for failure or operational
errors due to improper installation. Failure to comply with the previous statement may void the
EVOLUTION Dog Wash warranty.
Wash Products and Disinfectant
The EVOLUTION Dog Wash was designed around the wash products provided with the unit,
TROPICLEAN and KENNELSOL. The solution ratios suggested in this manual are for those
products only. Failure to use these products throughout the warranty period makes the
warranty voidable.
4
This circuit is for the main power to the unit. An additional dedicated 110 Volt AC / 20 Amp circuit is required if
the unit comes with the optional water heater.
Содержание Dog wash
Страница 1: ...OWNERS MANUAL evolutiondogwash com 888 303 0553 info evolutiondogwash com...
Страница 7: ...Evolution Dog Wash Owners Operators Manual Page 7 2 2 Models...
Страница 10: ...Evolution Dog Wash Owners Operators Manual Page 10 2 7 Dimensional Drawings...
Страница 23: ...Evolution Dog Wash Owners Operators Manual Page 23 4 4 4 Electrical Breaker Box Schematic...
Страница 40: ...Evolution Dog Wash Owners Operators Manual Page 40...
Страница 57: ...Evolution Dog Wash Owners Operators Manual Page 57 10 4 Dissenfectant KennelSol...
Страница 58: ...Evolution Dog Wash Owners Operators Manual Page 58...
Страница 59: ...Evolution Dog Wash Owners Operators Manual Page 59...
Страница 60: ...Evolution Dog Wash Owners Operators Manual Page 60...