POWER PACK INSTALLATION 

4.1 

The Evochlor Chlorinator power pack is wall mounted using the supplied mounting 
bracket or directly hanging on the wall with screws (300mm centres). The power pack 
must be mounted at least 1 metre above the ground and 3 metres or more from the 
pool edge. 

4.2 

It is strongly recommended that the power pack be installed where it is protected 
from the elements. Rain and sunlight will prematurely age the unit. It should also be 
mounted in a position where it is away from accidental water spray. The power pack 
should be installed so that adequate airflow can circulate freely around the unit to 
allow for sufficient ventilation.

4.3 

The power pack comes with a standard 230V 10A power cable that is to be connected to 
mains power. Plug the power cable into a suitable weatherproof outlet.

4.4 

The power pack is fitted with a 230V 10A power socket located on the right-hand 
underside of the power pack. The pool pump should be plugged into this socket so that 
the chlorinator and pump activate together when the timer switches on at the allocated 
time settings. In a model without a timer, the pump and chlorinator are controlled by 
the on/off switch (7 in Fig. 3). Failure to plug the pool pump into this socket could lead 
to the chlorinator staying on with no water circulation. Without circulation, and in the 
event of a water probe failure, overheating and a possible gas build-up may occur. This 
build-up may damage the cell housing.

4.5 

The electrolytic cell cable is connected to the power pack at the junction box on the 
underside of the unit. With power off, remove the protective cover from the junction 
box and insert the cell cable wires to the terminals, with the thin wire connecting to the 
middle position. The screws must be firmly tightened so there is solid contact between 
the wires and the terminals. Replace the protective cover back over the junction box.

Содержание A15TS

Страница 1: ...d by a qualified technician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual c...

Страница 2: ...F CONTENTS 1 0 FOREWORD 1 2 0 POOL CHEMISTRY 1 3 0 CELL INSTALLATION 2 4 0 POWER PACK INSTALLATION 3 5 0 OPERATION 4 6 0 MAINTENANCE 6 7 0 TROUBLESHOOTING 7 8 0 WARRANTY 8 9 0 NOTES 9 SALT WATER CHLOR...

Страница 3: ...uric Acid 40 65ppm Salt 4 000ppm Chlorine 1 5 3 0ppm 2 2 The Evochlor Chlorinator is designed to operate on a salt level of 4 000 parts per million ppm This is easily achieved by using the formula bel...

Страница 4: ...r the heater in the return line to protect the elements or heat exchanger If a solar heating system is fitted then the cell housing should be installed after the return line comes back from the roof i...

Страница 5: ...with a 230V 10A power socket located on the right hand underside of the power pack The pool pump should be plugged into this socket so that the chlorinator and pump activate togetherwhen the timer sw...

Страница 6: ...unt of chlorine production By simply turning the control clockwise chlorine output is increased and by turning the control anti clockwise chlorine output is decreased Do not force the control past its...

Страница 7: ...ial Outer Dial Minute Hand One tripper equates to 15 minutes Activation Point Fig 4 6 Circuit Breaker The circuit breaker mounted on the front right hand side of the Evochlor Chlorinator is designed t...

Страница 8: ...e wires at the junction box underneath the power pack these must be reconnected firmly and tightly 3 With the cell removed use a high pressure hose nozzle to spray off as much loose scale as possible...

Страница 9: ...4 000ppm and check stabiliser Cyanuric levels pH too high Adjust pH between 7 2 7 6 Timer period too short Increase running time High phosphate levels Treat pool water with phosphate remover Cell conn...

Страница 10: ...ons beyond the control of the manufacturer These include but are not limited to incorrect power supply must be 230V 50Hz the chlorinator connected to an ancillary device such as a Variable Frequency D...

Страница 11: ...9 9 0 NOTES...

Страница 12: ...wise indicated copyright in the content of this document is the property of Evolution Water and Lighting Solutions under Australian copyright law Unless otherwise indicated content may not be reproduc...

Отзывы: