Содержание A15TS

Страница 1: ...d by a qualified technician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual c...

Страница 2: ...F CONTENTS 1 0 FOREWORD 1 2 0 POOL CHEMISTRY 1 3 0 CELL INSTALLATION 2 4 0 POWER PACK INSTALLATION 3 5 0 OPERATION 4 6 0 MAINTENANCE 6 7 0 TROUBLESHOOTING 7 8 0 WARRANTY 8 9 0 NOTES 9 SALT WATER CHLOR...

Страница 3: ...uric Acid 40 65ppm Salt 4 000ppm Chlorine 1 5 3 0ppm 2 2 The Evochlor Chlorinator is designed to operate on a salt level of 4 000 parts per million ppm This is easily achieved by using the formula bel...

Страница 4: ...r the heater in the return line to protect the elements or heat exchanger If a solar heating system is fitted then the cell housing should be installed after the return line comes back from the roof i...

Страница 5: ...with a 230V 10A power socket located on the right hand underside of the power pack The pool pump should be plugged into this socket so that the chlorinator and pump activate togetherwhen the timer sw...

Страница 6: ...unt of chlorine production By simply turning the control clockwise chlorine output is increased and by turning the control anti clockwise chlorine output is decreased Do not force the control past its...

Страница 7: ...ial Outer Dial Minute Hand One tripper equates to 15 minutes Activation Point Fig 4 6 Circuit Breaker The circuit breaker mounted on the front right hand side of the Evochlor Chlorinator is designed t...

Страница 8: ...e wires at the junction box underneath the power pack these must be reconnected firmly and tightly 3 With the cell removed use a high pressure hose nozzle to spray off as much loose scale as possible...

Страница 9: ...4 000ppm and check stabiliser Cyanuric levels pH too high Adjust pH between 7 2 7 6 Timer period too short Increase running time High phosphate levels Treat pool water with phosphate remover Cell conn...

Страница 10: ...ons beyond the control of the manufacturer These include but are not limited to incorrect power supply must be 230V 50Hz the chlorinator connected to an ancillary device such as a Variable Frequency D...

Страница 11: ...9 9 0 NOTES...

Страница 12: ...wise indicated copyright in the content of this document is the property of Evolution Water and Lighting Solutions under Australian copyright law Unless otherwise indicated content may not be reproduc...