K1 MICRO BEAD FILTER INSTALLATION INSTRUCTIONS

We recommend following these instructions to install the K1 Micro Bead Filter.
1.   Remove the K1 Micro Bead Filter, the multi-port valve, air blower, pipe work, 

and fittings from the box, and familiarise youserlf with the parts. (See page 4 parts list).

2.  Set up the filter as shown on pages 11 to 14, ready for installation.

IMPORTANT: The unit must be installed on a flat, level base, on firm ground or equivalent. 
Ensure the ground will not subside and strain pipework. We recommend using a flat solid 
concrete surface as a base for installation. Depending on the model of your K1 Micro  
Bead Filter, the dimensions of this base will be different. 

3.  Position the filter as close as possible to the pond.
4.    The filter should also be in a location that is free from flooding, is away from sumps, 

guttering, garden hollows and areas that may experience sub-zero conditions etc. 
DO NOT position the blower in an area where it is exposed to rain-fall or water ingress.

5.    Allow room all the way around the K1 Micro Bead Filter to enable easy maintenance and 

servicing. Do not install the unit in a tight space.

6.    Make sure the multi-port valve and fittings are properly positioned. Hand tighten  

the unions only. The multi-port valve must not move during operation.

7.    Make pipe connections onto the valve. Pump line (inlet), return line and waste lines are 

marked on the valve. A ball valve, slide valve or non-return valve needs to be installed on 
the pumps suction line from the pond / pre-filter to the pump. We highly recommend a 
non-return valve (see figure 9). Refer to your pump manufacturer’s manual to see if the 
pump is self-priming. For the avoidance of doubt install your pump below the pond water 
level. Allow a full 24 hours for all glued pipework joints to harden.

8.   Install a UV on the return line back to the pond.
9.    Connect the air blower to the manifold (Figure 6b). Ensure the ball valve is attached, 

connected properly and the handle can be moved without restriction for cleaning.  
The air blower should be installed higher than the top of the filter. The air blower is  
only operated during the cleaning procedure. IMPORTANT: The ball valve must be in the 
CLOSED position when the circulating pump is running.

10.   If you have not already done so, remove the lid and pour the K1 Micro into the filter from 

the top. Then re-fit the lid (as shown on page 14).

11.  Set the multi-port valve to the FILTER position. Turn on the pump and allow the unit to fill 

with water. Check for any leaks. Your K1 Micro Bead Filter will be operational.

12.  When the unit is running, the biological side of the K1 Micro Bead Filter will take 

approximately 8 weeks to mature. We recommend adding PURE

POND

 

to the unit  

to drastically speed up this process.

Do not operate the multi-port valve with the circulating pump switched on.
The ball valve must be closed when the circulating pump is running.

Содержание K1 MICRO BEAD 20

Страница 1: ...0 1942 216562 e info evolutionaqua com w www evolutionaqua com UK English K1MICROBEAD011703171MAN PLEASE READ INSTALLATION INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION PLEASE NOTE Do not operate the m...

Страница 2: ...l filtration along with unparalleled biological filtration This is due to the vast PROTECTED SURFACE AREA of K1 Micro filter media The media also improves flow through the filter meaning lower energy...

Страница 3: ...Multi Port Valve PAGE 9 K1 Micro Bead Filter installations PAGE 10 K1 Micro Bead Filter set up PAGE 11 K1 Micro Bead Filter installations PAGE 15 K1 Micro Bead Filter cleaning instructions PAGE 16 Qu...

Страница 4: ...upplied with 2 MPV 4 PRESSURE GAUGE AND FITTINGS 3 AIR BLOWER 20 and 24 models supplied with 200W Air Blower 30 and 36 models supplied with 300W Air Blower 5 COVER CAPS FOR LID 6 INLET AND OUTLET THRE...

Страница 5: ...This is designed to prevent water flowing back into the air blower Only open the ball valve when the pump is switched off and before operating the air blower FAILURE TO FOLLOW THESE INSTRUCTIONS MAY...

Страница 6: ...TER 24 20 964mm 1085mm 400mm 230mm 940mm 330mm 230mm 610mm 805mm 290mm 155mm 500mm 265mm 155mm 760mm Figure 2b K1 MICRO BEAD 30 FILTER Figure 3a 24 30 36 20 964mm 793mm 940mm 330mm 230mm 610mm 500mm 2...

Страница 7: ...LETS TO SCREW INTO MPV FIT TO MPV ON 24 MODELS ONLY A D E B A C 7 MPV AND BLOWER PIPEWORK FITTINGS SUPPLIED WITH 20 MODELS FIT BETWEEN AIR BLOWER AND BALL VALVE TO REPLACE COLLAR INSERTS ON FILTER INL...

Страница 8: ...filter bacteria biologically breaks down the Ammonia and Nitrite into Nitrate The filtered water is returned to the top of the unit through the multi port valve and back to the return line flowing ba...

Страница 9: ...1 Micro filter media With the valve in this position air supplied by the air blower is used to agitate the filter media Later on in the cleaning process water is used to rinse the K1 Micro and exit to...

Страница 10: ...Micro Bead Filter can be installed as shown above if you are planning to use a pre filter such as the Evolution Aqua Cetus Sieve If you are not planning to use a pre filter we highly recommend that y...

Страница 11: ...e 4 and 7 Discard the inserts supplied with the threaded collars Fit the threaded collar with the insert A onto the outlet Fit the threaded collar with the insert A onto the outlet and tighten up Inst...

Страница 12: ...he pre assembled pipework with ball valve and insert 17cm pipe D between the MPV and 2 Elbow Glue connections ON ALL MODELS Screw insert C into the female thread on the MPV HAND TIGHTEN ONLY Take the...

Страница 13: ...ug on the valve Fit the larger washer on the threaded end ready to screw into the lid Screw valve into the larger female threaded end on the elbow Screw the pressure gauge assembly into the lid DO NOT...

Страница 14: ...the nuts Then tighten alternate nuts with a spanner in sequence i e at 12 o clock and 6 o clock then 1 o clock and 7 o clock Tighten to a reasonable degree DO NOT OVER TIGHTEN Fit the plastic caps ove...

Страница 15: ...return line and waste lines are marked on the valve A ball valve slide valve or non return valve needs to be installed on the pumps suction line from the pond pre filter to the pump We highly recommen...

Страница 16: ...glass on the MPV and when the water runs clear switch off the pump 7 Turn the MPV to the BACKWASH position Switch the pump on and look at the sightglass on the manifold Water is going to waste After a...

Страница 17: ...ice QUICK CLEANING BACKWASH INSTRUCTIONS PUMP OFF RINSE AND BLOWER FOR 2 MINUTES RINSE AND PUMP UNTIL CLEAR BACKWASH AND PUMP UNTIL CLEAR RINSE AND PUMP UNTIL CLEAR FILTER AND PUMP Switch PUMP OFF Tur...

Страница 18: ...pen the drain plug at the base of the unit Water will drain from the vessel 5 Loosen all connections and drain water from valves pipes pumps and UVs Ensure that no water is trapped Remember water can...

Страница 19: ...the multi port valve Scoring or jamming with foreign matter or debris If this condition persists after rinsing disassemble the valve to clear Continued operation may result in leaking due to damage to...

Страница 20: ...ken by Evolution Aqua Ltd or its authorised representatives c A proof of purchase will be required when making a warranty claim 2 Though the warranty period may not have expired payment for repairs mu...

Страница 21: ...n the following cases a When the fault is due to misuse or unauthorised repairs have been attempted b When the fault is due to fire natural disaster act of God etc c If the warranty has been lost inco...

Страница 22: ...n form will amount to your consent for us to disclose your details and other personal information to other companies within the Evolution Aqua group including any subsidiary company or subcontractor o...

Страница 23: ...NOTES...

Страница 24: ...tration manufacturer who put innovation research and development at the top of their agenda With a proven track record for delivering the latest technology to the aquatics and fish farming markets we...

Отзывы: