Infinium 12 000 RGB FB4 User Manual Ver. 1.00
Page 14
allow one beam output. (Be caution when you turn it off.)
10
Key switch
Turn the key switch ON to allow laser output.
11
Power in
AC100~240V power input socket.
Maintenance & service
o
Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s
optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days
There is no replaceable parts inside. DO NOT OPEN THE FIXTURE
o
Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
The fixture does not aork, no light
o
Check the connection of power and main fuse.
o
Measure the mains voltage on the main connector.
o
No light out
o
Please check if the interlock connector is connected
o
Please check if the safety key position is set to ON
Technical Specifications
Model
Infinium 12 000 RGB FB4
Source
Class 4 LASER light
Voltage
230v 50Hz
Power consumption:
350 W max
Outside size and N.W.:
356x276x123 mm
14.7
kg
EN60825-1:2014, application of the European Directives :