Evolite Infinium 12000 RGB FB4 Скачать руководство пользователя страница 10

 

Infinium 12 000 RGB FB4 User Manual Ver. 1.00 

Page 10 

 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

LASER light can cause permanent eye injuries if eyes are exposed to the laser light. 

 

Disconnect main power before servicing and maintenance. 

 

Maximum ambient temperature is: 40

. Don’t operate it when the temperature is higher than this. 

 

In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture 
by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the 
nearest authorized technical assistance center. There are no user serviceable parts inside the fixture except 
the fuse. 

 

Do not connect the device to any dimmer pack. 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture. 

 

Do not look directly at the LASER light beam while the fixture is on. 

 

  Do not touch any wire during operation. 

 

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to 
avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching 
the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety 
cable that can hold 12 times of the weight of the unit when installing the fixture. 

 

The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of 
people and has no one pass by or under it. 

 

Operating  Premises:  Whenever  possible,  the  operation  of  a  LASER  should  be  done  in  a  room  or  in  an 
enclosed or delimited place for this purpose. 

 

The access of room and openings to the outside must not be located in the axis of a direct beam. 

 

The floor must be free of obstacles. The causes of accidental reflection and scattering of laser beams must 
be removed (misplaced windows, furniture or objects with polished faces). 

 

The paintings (walls, partitions, ceilings ...) and flooring should preferably be matt. The diffuse reflections of 
class  4  lasers,  focused  beams  of  lasers  of  class  3  to  visible  or  near  infrared  light  should  be  considered 
dangerous and treated as such. 

 

When  using  powerful  lasers  (Classes  3  to  focused  beam  or  4),  eliminate  the  beam  potential  impact  on 
flammable materials (wood, paper, fabric or plastic) that can be in from fire in power densities of the order 
of several W.cm-2 applied for a few seconds. 

 

The access to the laser emission zones should be reported using the signs in accordance with the Ministerial 
Decree of 4 November 1993 "Signs of safety and health in the workplace" and the NF X 08-003 "Symbols 
graphics and symbols - colors and safety signs "of December 1994. This signaling is completed by the words 
of the class of laser product and the instructions provided in the NF EN 60825-1 standard. Such access can 
be controlled, at least when lasers are operating. 

 

Emissions control: the control panel should be placed outside the locations exposed to hazardous emissions. 
The control of lasers in Classes 3 and 4 should be under the control of a key control, removed when the 
device is not in use and owned by a qualified person. 

 

Disclaimer: The use of this device is exclusively for professional activities show and display. 
 
 

 

It is forbidden to allow projecting the beams to the audience and any areas accessible by persons without 
appropriate eye and skin protective items. It is forbidden to use this device for any other purpose than that 
for which it is intended. 

 

It is forbidden to shine any laser beam to the aircrafts. 

 

If the laser is operated in a situation where health or property injury may occur, operation MUST be stopped 
immediately! 
 

Manufacturer and distributors are not responsible for any damages caused by use of  EVOLITE lasers. User is 
responsible for applying conditions of use according to regulations stipulated in in EN60825-1:2014, application 
of the  European Directives : 
 

Содержание Infinium 12000 RGB FB4

Страница 1: ...12 000 RGB FB4 User manual Mode d emploi...

Страница 2: ...lectriques Il est important d utiliser le c ble d alimentation secteur fourni c ble avec terre Toujours d brancher l appareil avant une intervention technique ou avant son entretien Ne pas brancher ce...

Страница 3: ...ochet solide et de dimension ad quate au poids support L appareil doit tre viss au crochet et serr convenablement afin d viter toute chute due aux vibrations produites par la machine en fonctionnement...

Страница 4: ...e personne qualifi e Avertissement L usage de cet appareil est exclusivement r serv aux activit s professionnelles de spectacle et d affichage Lors de son utilisation cet appareil doit tre install de...

Страница 5: ...mrad Taille du faisceau 6x5 mm Modulation RGB 0 5V analog 50Khz Taille du miroir de scan X 11x11x1 05mm Taille du miroir de scan Y 9x16 5x1 05mm Angle de projection max 60 Modulation Analogique Classe...

Страница 6: ...recopie du FB4 3 Boutons rotatifs R glage des axes X Y intensit lumineuse du R V B sensisbilit du microphone 4 Interface Pangolin FB4 Max Ecran de contr le de l interface FB4 5 ILDA in out Entr e Sort...

Страница 7: ...s pour une luminosit optimum Si l appareil est install dans un environnement poussi reux ou avec de la fum e cet entretien r gulier est tr s important Utilisez un chiffon doux et propre avec tr s peu...

Страница 8: ...tation 230v 50Hz Scans galvanom tres 35 kpps 8 max 60 Consommation lectrique 350 W max Protocol de contr le ILDA Fusible T5A Homologations EN60825 1 2014 en application des Directive Europ ennes suiva...

Страница 9: ...power pack Protect the unit from rain or moisture WARNING Fire Hazard Keep flammable materials away from the fixture Do not operate the fixture with ambient temperature over 40 C Do not place any fil...

Страница 10: ...beams must be removed misplaced windows furniture or objects with polished faces The paintings walls partitions ceilings and flooring should preferably be matt The diffuse reflections of class 4 lase...

Страница 11: ...D EYE EXPOSURE TO DIRECT OR SCATTERED RADIATION DANGER AVOID SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION Some ILDA softaare aill offer to adjust the scan speed beyond the Infinium 12 000 RGB s capa...

Страница 12: ...irror size Y 9x16 5x1 05mm Max projection angle of 60 Analog Modulation Class 4 Buttons for adjusting the light intensity of each source on the rear panel Control modes via the FB4 Pangolin box includ...

Страница 13: ...to be installed out of the reach of people Always secure your fixture with a safety cable This backlighted LCD display indicates the fixture is DMX addressed the fixture status set up values etc NO Na...

Страница 14: ...very 20 days Clean the internal optics at least every 30 60 days There is no replaceable parts inside DO NOT OPEN THE FIXTURE o Troubleshooting Following are a few common problems that may occur durin...

Страница 15: ...Infinium 12 000 RGB FB4 User Manual Ver 1 00 Page 15 aaa evolite pro com Import par Imported by EVOLITE MSC 7 avenue du 1er Mai 91120 Palaiseau FRANCE infos msc distribution com Tel 33 1 69 34 80 62...

Отзывы: