background image

SOLACE SERIES

SWIMMING POOL DEHUMIDIFIER

              

              

Installation & Operation Manual

Содержание Solace 1.25

Страница 1: ...SOLACE SERIES SWIMMING POOL DEHUMIDIFIER Installation Operation Manual...

Страница 2: ...nciple 3 5 Product Features 3 6 Hygrostat Control 4 Installation 5 Usage 5 1 Instruction for Operation Panel 5 2 Operation Instruction 6 Maintenance 7 1 PCB I O Port 7 2 Wiring Diagram Safety Precauti...

Страница 3: ...truction must be kept carefully and must always accompany the appliance If it is lost or damaged please contact the local technical service center 1 1 Fail to comply with these recommendations will in...

Страница 4: ...ated Do not put fingers or others into the fan or evaporator of the unit otherwise harm may be occurred OPERATION PROHIBITION SHUT OFF THE POWER When the unit needs to be moved or installed again plea...

Страница 5: ...agent or similarly qualified persons in order to avoid a hazard 7 It is forbidden to poke objects or anything else through the inlet or outlet grills 8 It is forbidden to dispose of or leave in the re...

Страница 6: ...20 240V 50Hz 10 36 See nameplate package label R410A 600g See 3 3 Operation Pressure Side High Operation Pressure Side Low Condensation Pipe Diameter 4 4 2 1 16 4 4 2 1 16 Model Rated Capaclty Air Vol...

Страница 7: ...mance Curve Solace 2 5 40 35 30 25 20 15 10 5 0 0 0 5 1 0 1 5 2 0 l h C 0 40 RH 2 5 60 RH 80 RH 40 35 30 25 20 15 10 5 0 0 0 5 1 0 1 5 2 0 l h C 0 40 RH 3 5 60 RH 80 RH 2 5 3 0 40 35 30 25 20 15 10 5...

Страница 8: ...coil of the refrigeration device condenses the water which is removed then the air is reheated by the hot coil This process works most effectively with higher ambient temperatures with a high dew poin...

Страница 9: ...e perfectly combined with your pool house 3 5 4 Newly design controller With simple operating display the newly developed controller makes the unit operation easier and more user friendly 3 6 1 The de...

Страница 10: ...as filter cleaning 4 2 Positioning 4 2 1 Avoid installing the unit in proximity to positions subject to exposure to direct sunlight sources of heat in places with oil fumes places subject to high freq...

Страница 11: ...6 Attention If the condensation water discharges directly into a container the condensate outlet should above the container to avoid immersing in the container Select a suitable size hose to connect t...

Страница 12: ...the target setting value DOWN 10 RH Defrosting Dehumidifying Press this button once to check the target setting value of relative humidity Press it again can decrease the target setting value Tips Wh...

Страница 13: ...Set the target value of relative humidity Press or to check the target relative humidity 11 RH RH Actual relative humidity The selected mode RH RH Press or again to change the target relative humidit...

Страница 14: ...ction Operation panel will display the failure codes when the unit gets some malfunctions Please refer to page15 to check the meaning of failure codes RH 5 2 3 Dehumidifying mode When the unit is in d...

Страница 15: ...an up the unit every six months Please take the following steps to clean up the strainer regularly 1 Pull out the grill A from the upside of it Fig 8 2 After that pull out the grill Fig 9 then lift th...

Страница 16: ...urn grille to the original place Fig 14 5 Clean up the unit outer with soft and damp rag Fig 15 To protect the paint coat of the unit please don t use rough sponge or corrosive detergent to do these W...

Страница 17: ...roubleshootings High pressure protection Condenser outlet temp overhigh Evaporator outlet temp sensor failure Humidity sensor failure Motor feedback signal failure Evaporator inlet temp sensor failure...

Страница 18: ...HUMI01 HUMI02 CN7 EEV PROG1 L N1 N_Comp N_Valve L_Comp Meaning To operation panel Reserved To fan motor DC To evaporator inlet outlet temp sensor To condenser outlet temp sensor To the build in hygro...

Страница 19: ...S TEMP2 HUMI01 HUMI02 TEMP 1 EEV CN1 FM PACC1001 t t 5K CdOT t 5K C1 Operation Panel TO POWER SUPPLY HPS CN7 CdOT Condenser OutletTemperature SS Sensitive Switch EvOT Evaporator Outlet Temperature EvI...

Страница 20: ...Code 20121115 0004...

Отзывы: