CHAPTER 1
Installation
Example of a unit with a
refrigerant leak and zero
pressure – notify
Evoheat Dealer.
Before installation it is very important to ensure 4 variables
are carefully checked to allow the unit to operate correctly:
1. Adequate Air Flow
2. Correct water flow volume
3. Correct electrical connection & supply
4. Heater condition
1. Air Flow
Installing the heater indoors or in an enclosed space will result in very poor performance and
can in extreme cases damage the heater. Ensure the heater is installed in a well ventilated
area with plenty of fresh air, a minimum gap between walls/fences etc of 600mm on the
sides and 1500mm overhead clearance.
Important: Ensure that the cold air off the top of the heater does not
recycle through the heater.
SEE PAGE 8 FOR FURTHER INFORMATION
2. Water Flow
It is CRITICAL that there is sufficient water flow to the unit. Incorrect water flow can cause a
loss of efficiency and possible damage to the unit. Optimal water flow rates are listed in the
Evoheat sales brochure and in this manual on page 5. It is imperative that water flow is kept
as close as possible to these flow rates. Correct water flow not only offers optimal heater
performance, but may also prevent possible damage to your heater.
SEE PAGE 9 FOR FURTHER INFORMATION
3. Electrical Connection
Always use a qualified Electrician to perform any electrical work. Ensure the power cable and
circuit breaker are of a suitable size for the heater being installed. Also check that there is
adequate voltage and current available at the heater connection to run the unit. Voltage range
should be 220-240 volts for single phase, and 380-415 volts for 3 phase units. Voltage ranges
outside these parameters will cause heater damage and void your warranty. Correct phase
connection is important with 3 phase heaters.
SEE PAGE 10 FOR FURTHER INFORMATION
4. Heater Condition
Check the heater packaging upon delivery for any obvious signs of damage. Inform your
supplier IMMEDIATELY if there is any evidence of rough handling.
When the heater has been removed from the packaging check the refrigerant gauge on the
front panel of the unit. The gauge should be showing a pressure of approx 1Mpa on the
outside black band – any less than this figure means there may be a leak in the refrigerant
system and you should immediately contact your Evoheat Dealer.
3. General installation information
3.1 Inspection
Inspect the packaging, the heater and other items after receipt for possible damage in
transportation. Please contact your EVOHEAT dealer immediately should you suspect any
damage has occurred during transportation.
Install your EVOHEAT heat pump in accordance with the procedures in this manual. Always
check that your installation will comply with local building and council regulations.