44
04-2017 5325 00
HEatiNg
uNit
paramEtErs
-Temperature: sets the operating tempera-
ture of the heating unit.
-Minimum temperature for dispensing bev-
erages: sets the minimum temperature for
making beverages available.
If the heating unit temperature is lower
than the temperature that has been set, a
“low temperature” error message will be
displayed.
With the "Temperature threshold" and "Min-
utes” parameters, the heating unit’s tem-
perature maintenance cycle can be set.
For example, if no beverages are dis-
pensed during the set minutes, the tem-
perature of the water in the heating unit is
increased by the degrees set in the "Tem-
perature threshold".
mixEr
aNti
-
lock
Sets how long after the last instant selec-
tion to briefly activate the mixers (anti-lock
function).
The function is useful if instant powder resi-
dues remain in the mixers.
MACHINE INFORMATION
faults
The appliance has a number of sensors
which keep the various functional groups
under control.
When an anomaly is detected, the appli-
ance displays the type of fault and the ap-
pliance (or part of it) is put out of service.
Detected faults are stored in specific coun
-
ters.
fault
History
This function makes it possible to view a list
of the fault history; the fault history contains
the name of the fault with the date and time.
The function shows if there is still a fault
and/or if it has been resolved.
With this function, the list of reported faults
can be reset to zero.
EvENt
History
This function allows the events reported by
the appliance to be viewed and filtered.
Examples of possible events are menu ac-
cess, parameter changes, etc.
With this function, the list of reported events
can be reset to zero.
faults
Displays the faults found on the appliance.
If there are no faults, the list will be empty.
DosiNg
DEvicE
fault
..
N
..
If the current absorption of a motor-doser
does not fall within the range of prede-
termined values, all the selections which
involve that motor-doser will be disabled.