MAINTENANCE

Before manipulating the fan, make sure it is disconnected from the mains supply - even if it 

has previously been switched off. Prevent the possibility of anyone else connecting it while 

it is being manipulated.
The apparatus must be regularly inspected. These inspections should be carried out while 

bearing in mind the machine's working conditions, taking care to avoid dirt or dust accumu-

lating on the propeller, turbine, motor or grids. This could be dangerous and perceptibly 

shorten the working life of the fan unit. While cleaning, great care should be taken not to 

damage the propeller.
All maintenance and repair work should be carried out in strict compliance with each coun-

try's current safety regulations.

The fan included with this ventilation system is designed as simply plug in and go 

without requiring user intervention.

The smart in-built electronics are constantly monitoring the incoming air quality.

The fan will vary its speed between very low and very high rates (10 - 100%) depending on 

the quality of the air to maintain a comfortable and moisture-free indoor environment. 
This system is capable of ventilating at very low rates while still bringing in enough fresh air 

into the house in situations where other systems would simply switch off. 
Maintaining correct ventilation of the house is important in order to prevent heat and energy 

losses and to allow you to enjoy a healthier indoor environment.

EVO

AQ

Air Quality Innovation

EVOAQ Ventilation Fan Specifications

Fan Size

Voltage (V/Hz)

Power (W)

Air Flow (m³/hr)

Static Pressure (Pa)

Noise Level (dB)

Speed (RPM)

Weight (kg)

Specific Fan Power (SFP)

200mm

230 / 50

3 - 165

63 ~ 1228

580

38

500 - 3000

3.5

0.294 W/Ls

-1

150mm

230 / 50

3 - 73

65 ~ 650

457

31

500 - 3000

2.5

0.398 W/Ls

-1

125mm

230 / 50

2 - 17

65 ~ 284

159

28

250 - 2250

2.5

0.175 W/Ls

-1

Содержание Home Ventilation

Страница 1: ...starting work will guarantee the fastest and best results regarding the installation EVOAQ Air Quality Innovation 28 375 East Tamaki Road Auckland 2013 09 558 5590 www evoaq co nz Working in the ceiling space can be a hazard and all safety precautions should be used to ensure the safety of yourself and any others EVOAQ Air Quality Innovation Home Ventilation ...

Страница 2: ...s The duct system must be used exclusively for the ventilation system The appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that they do not play with the appliance ELECTRICAL CONNECTION The ventilation fan must be co...

Страница 3: ...ngth of ducting to each diffuser The shortest length of ducting should be no shorter than 3 metres Avoid tight bends in the ducting Ensure the ducting is stretched out fully Cut the ducting if needed Avoid installing the ducting where it may be crushed or damaged by you or other tradesmen Avoid installing the diffusers near doors hallways and directly above beds or couches If a wall controller is ...

Страница 4: ...below For optimal airflows keep the duct straight and level with the fan Place the fan away from bedrooms to minimise noise issues We recommend positioning the fan and filter close to the manhole for easy access for servicing The filter should be checked at least every 12 months and replaced at least every 2 years or earlier if necessary The fan should fit on the filter directly and does not requi...

Страница 5: ...ring of summer kit and heat transfer add ons check the respective manuals or contact us for more information Ventilation Controller EVOAQ Ventilation Fan 10m Netw ork Cable External Fan Wall Controller Wall Controller or Air Source Control Box External fan only used in balanced or heat transfer Cable connection to ventilation fan ...

Страница 6: ...4 Room Sample Layout ...

Страница 7: ...6 Room Sample Layout ...

Страница 8: ... with this ventilation system is designed as simply plug in and go without requiring user intervention The smart in built electronics are constantly monitoring the incoming air quality The fan will vary its speed between very low and very high rates 10 100 depending on the quality of the air to maintain a comfortable and moisture free indoor environment This system is capable of ventilating at ver...

Отзывы: