Thank you for your purchase of our company’s products. This system has been 

manufactured following current technical safety regulations and is in compliance with 

AS/NZ60335 standard.

Please read this instruction booklet carefully before installing the system.

 

It contains important information on personal and user safety measures to be followed while 

installing, using, and carrying out maintenance work on the equipment. Once the product 

has been installed, please hand this booklet to the end user.

TRANSPORT AND MANIPULATION

The packaging used for this system has been designed to support normal transporting 

conditions. The product must always be transported in its original packaging as not doing so 

could deform or damage the product. Do not place heavy weights on the packaging and 

avoid knocking or dropping it.
Check that the apparatus is in perfect condition while unpacking. Do not accept delivery if 

the apparatus is not in its original packaging or shows clear signs of having been 

manipulated in any way. Any fault or damage caused in origin is covered by our company 

guarantee. Please make sure that the apparatus coincides with the product you have 

ordered and that the details on the rating label fulfil your requirements.
The product should be stored in a dry place in its original packaging, protected from dust 

and dirt until it is installed in its final location.

IMPORTANT INFORMATION

Installation must only be carried out by qualified persons. Make sure that the installation 

complies with the applicable building and electrical regulations. The fan appliance must not 

be used in explosive or corrosive atmospheres. The duct system must be used exclusively 

for the ventilation system.
The appliance is not intended for use by young children or infirm persons unless they have 

been adequately supervised by a responsible person to ensure that they can use the 

appliance safely. Young children should be supervised to ensure that they do not play with 

the appliance. 

ELECTRICAL CONNECTION

The ventilation fan must be connected to a single-phase mains network, with the specific 

voltage and frequency according to the specifications on the fan rating label.

The electrical installation must include an isolating switch with a contact clearance of at least 

3 mm, correctly sized and in accordance with the electrical standards.

Earthing is not required as this fan has double insulation (Class II).
If the fan model you have purchased is not fitted with a power cord then please note that it 

must be wired with a fixed permanent connection. Disconnect the mains supply before 

making any electrical connection. If in any doubt contact a registered electrician.

SAFETY DURING INSTALLATION

Make sure there are no loose elements near the fan, as they could run the risk of being 

sucked up by it. When connecting the fan to the ducting, check that the ducting is clean of 

any element that could be sucked up by the fan. During installation of the fan, make sure 

that all the fittings are in place and that the structure which supports it is resistant enough 

to bear its weight at full functioning power.
Fans may have a delayed start-up time or operate under the control of their inbuilt 

electronics. Always take extreme care as the unit may start unexpectedly. Before carrying 

out any maintenance, make sure the mains supply is disconnected, even if the machine is 

switched off. Never insert your hands into the inlet side of the fan without first unplugging 

the fan. 

Содержание Home Ventilation

Страница 1: ...starting work will guarantee the fastest and best results regarding the installation EVOAQ Air Quality Innovation 28 375 East Tamaki Road Auckland 2013 09 558 5590 www evoaq co nz Working in the ceiling space can be a hazard and all safety precautions should be used to ensure the safety of yourself and any others EVOAQ Air Quality Innovation Home Ventilation ...

Страница 2: ...s The duct system must be used exclusively for the ventilation system The appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that they do not play with the appliance ELECTRICAL CONNECTION The ventilation fan must be co...

Страница 3: ...ngth of ducting to each diffuser The shortest length of ducting should be no shorter than 3 metres Avoid tight bends in the ducting Ensure the ducting is stretched out fully Cut the ducting if needed Avoid installing the ducting where it may be crushed or damaged by you or other tradesmen Avoid installing the diffusers near doors hallways and directly above beds or couches If a wall controller is ...

Страница 4: ...below For optimal airflows keep the duct straight and level with the fan Place the fan away from bedrooms to minimise noise issues We recommend positioning the fan and filter close to the manhole for easy access for servicing The filter should be checked at least every 12 months and replaced at least every 2 years or earlier if necessary The fan should fit on the filter directly and does not requi...

Страница 5: ...ring of summer kit and heat transfer add ons check the respective manuals or contact us for more information Ventilation Controller EVOAQ Ventilation Fan 10m Netw ork Cable External Fan Wall Controller Wall Controller or Air Source Control Box External fan only used in balanced or heat transfer Cable connection to ventilation fan ...

Страница 6: ...4 Room Sample Layout ...

Страница 7: ...6 Room Sample Layout ...

Страница 8: ... with this ventilation system is designed as simply plug in and go without requiring user intervention The smart in built electronics are constantly monitoring the incoming air quality The fan will vary its speed between very low and very high rates 10 100 depending on the quality of the air to maintain a comfortable and moisture free indoor environment This system is capable of ventilating at ver...

Отзывы: