7
36” clearance to ceiling from cooktop surface
CLEARANCE DIMENSIONS
12” clearance to sidewall
from cooktop surface
12” clearance to backwall
from cooktop surface
Read the instructions carefully in this booklet to install the
Evo Affi nity 25E Cooktop to a metal, stone or wood countertop surface.
Cabinet layout and construction may vary.
Minimum 3” clearance required under unit
venting to 22 sq/in of combustible air.
Do not install above any equipment, table or shelving where
air temperature is greater than ambient air temperature.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION FROM CHASSIS
Combustibles
Non-combustibles
Back
0”
0”
Sides
0”
0”
Bottom
3”
3”
CLEARANCE TO COMBUSTIBLE SURFACE FROM COOKING SURFACE
Top
36”
Sides
12”