![Evo affinity 25E Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/evo/affinity-25e/affinity-25e_owners-and-installation-manual_2446276021.webp)
INSTALLATION INSTRUCTIONS
A f f i n i t y 2 5 E
Evo, Inc. | 8140 SW Nimbus Ave., Bldg 5 | Beaverton, Oregon 97008 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | [email protected]
21
CPU
SSR
1/L1
2/T1
4/A2
+3/A1
50AMP 48-660VAC
4-32VDC
SSR
1/L1
2/T1
4/A2
+3/A1
50AMP 48-660VAC
4-32VDC
1
2
3
4
5
6
7
8
1
2
5
6
7
8
11
12
L2
L1
4
3
2
1
INNER
12vdc
OUTER1
12vdc
OUTER 3
12vdc
12VDC FAN
12VDC FAN
CPU
POWER
12vac
4
3
2
1
INNER HEATER
19.2
ё
OUTER HEATER
8.3
ё
SSR1
Z1
Z2
T1
SD
SD
T2
SD
SD
CSG
EG
CG
SSR2
ENG
OUTPUTS
INPUTS
INNER
12vdc
OUTER 1
12vdc
OUTER 2
unused
OUTER 3
12vdc
Inner
TC (K)
+
Outer 1
TC (K)
+
Outer 2
TC (K)
+
Outer 3
unused
+
RC
D1
D2
TX
TB
J1
P1
EG: Earth Ground
CG: Chassis Ground
CSG: Cook Surface Ground
ENG: Enclosure Ground
SSR1: Inner Control Relay
SSR2: Outer Control Relay
Z1: Inner Heat Zone
Z2: Outer Heat Zone
T1: Inner Auto Reset Snap Disc
T2: Outer Auto Reset Snap Disc
TB: Terminal Block
TX: Transformer
CPU: Central Processing Unit
RC: Display Ribbon Cable
D1: LED Display Board
D2: Display Overlay (w/dome
switches)
J1: Panel Mount Housing
Molex #428180412
P1: Locking Housing
Molex #428160412
208-220VAC
1Phase
30Amp dedicated
On/off
Mode
30AMP ELECTRICAL SCHEMATIC
PART #: 10-0062-EL & 10-0061-EL
208V - 230V, 1-Phase, 50-60Hz
30AMP Dedicated Circuit
208V / 5.37 kVA
230V / 6.56 KVA