5.5.
Open a tap behind the softener so a flow runs through it. Some air may flow
from the tap; this comes from the softener. This will happen only once; at
start-up. Once only water flows from the tap, and no more air, close the tap.
5.6.
Perform a manual regeneration.
5.6.1.
Use a hex key number 5 to turn the program disk (PRG) manually.
T
u
r
n
P
R
G
c
o
u
n
t
Turn programm counter clockwise until it is in above position. When the arrow
and the small line on the transparent cover reach the area marked by “B”
(brining), the regeneration will start. Immediately, the PRG will drop down a
little (you will be able to see and hear this). “R” stands for refill (refilling the
container with water at the end of the regeneration stage). To make sure the
softener is in regeneration, there should be a small water flow to the drain,
and the water level in the container should drop.