4.2
Blending regulator:
= part number 8 on the illustration on page 1
With the blending regulator, you can
determine the outgoing hardness.
Depending on the desired residual
hardness, set outgoing hardness
with a hex key number 5. The
setting is proportional, i.e. 1/10 –
1/5 – 1/… of total incoming
hardness.
5.
Start up:
5.1.
Leave Bypass in “bypass” mode, open main valve and flush for several
minutes in order to avoid impurities from entering the softener. When you do
not use a Bypass, open the main valve slowly as described in
5.4
.
5.2.
Fill salt bin with salt in the provided
space.
Use only specific salt
tablets that are suitable for
softeners.
5.3.
Add water in the salt bin until the
water level is approx. 10cm (4”) high.
(the floater on the brine valve must be
afloat)
5.4.
Turn the bypass slowly to “service”
mode. Open the main valve when you do not use a Bypass.