Hydraulic connections
Connection arrangement.
Ensure that the hydraulic connections of the pipework piped up to the unit are
correct and follows the hydraulic schematic. The manufacturer cannot accept any
responsibility for any damage caused to the unit due to crossed connections.
Any Evinox engineer callout/visit due to this issue will be chargeable.
The ModuSat® heat interface unit is designed
to be wall mounted with the typical primary
connections and domestic water hydraulic
connections as shown below. (Other
configurations are available; please refer to
pages 10 - 13 of this manual for details).
The Evinox Energy flushing by-pass valve kit
should be installed prior to connecting the unit
and the valves left in an isolated position.
The whole system should be cleaned and
flushed before installing the heat interface unit
to ensure the ModuSat® unit is not damaged.
Wall fixing
The ModuSat® unit is designed to be wall mounted. There are drillings on the back plate of the unit
that ensure mounting with the wall fixing bracket.
Use of Pre-installation Rig
A pre-installation rig is available upon request. It consists of a back panel constructed of steel. This
will enable the installer to arrange the piping entering and leaving the unit during first fix prior to the
unit being delivered / installed. The configuration of the pre-installation rig will be as per the unit
being supplied and the project requirements.