6
ALARM_REPORT and BATTERY_REPORT_COMMAND
Grouping 2 includes BASIC_SET
1-1 Grouping 1 (Max. Node = 1)
1-1-1 POWER_APPLIED command
Whenever power is applied, it will send ALARM_REPORT command to the
nodes of Grouping 1 to inform associated devices that the sensor is
powered up.
ALARM_REPORT Command
[Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01]
1-1-2 MULTILEVEL_SENSOR_REPORT
The sensor will emit SENSOR_MULTILEVEL_REPORT to inform the nodes
of Grouping 1 automatically its current lux. Refer to the section of
Z-Wave’s Configuration for settings of auto report and wakeup
configuration.
Illumination:
SENSOR_MULTILEVEL_REPORT
[Command Class Sensor Multilevel, Sensor Multilevel
Report, Sensor Type = 0 x 03 (Luminance),
PrScale+Size = 0 x 0A, Sensor Value 1 = (High Byte
of Illumination Value), Sensor Value 2 = (Low Byte of
Illumination Value)]
Example:
Sensor Value 1 = 0x08
Sensor Value 2 = 0x02
Illumination = (Sensor Value 8*256 + Sensor Value 2)
=
(8*256+2)
=
2050
(LUX)
1-1-3 Low Battery Report
When the battery level of the sensor drops to an unacceptable level, the
icon
will appear on the LCD and the sensor will emit ALARM_REPORT
command to the nodes of Grouping 1.
ALARM_REPORT Command:
[Command Class Alarm, Alarm Type = 0x01, Alarm Level =
255(0xFF)]
The users can also enquire the battery status of the sensor by sending
BATTERY_ GET command via controller. Once the sensor receives the
command, it will return BATTERY_REPORT command.
BATTERY_REPORT Command
[Command Class Battery, Battery Report, Battery Level =
20%-100%]
If it displays with a message of “Battery Level = 255 (0xFF)”, it implies that
the sensor is at low battery status. Please replace the batteries as soon as
possible, otherwise the sensor will enter Shut Down mode.
Note:
The sensor will emit a low battery command as long as there is a device
associated into Grouping 1 of Illumination Sensor, even if the RF function
is set to disable.
If sensor enters Shut Down mode, the LCD display will be extinguished
and no RF signal will be emitted.
1-2 Grouping 2 (Max. Node = 3)
1-2-1 BASIC_SET
When the sensor is triggered, it will emit BASIC_SET_COMMAND to the
nodes of Grouping 2.
[Command Class Basic, Basic Set, Value = (255)0xFF]
: send
trigger-ON command
[Command Class Basic, Basic Set, Value = 0(0x00)]
: send
trigger-OFF command
Please refer to the table below, configuration parameter 1, for the setting of
basic set command.
2. Z-Wave’s Configuration
The table below lists the configuration parameters and the value range for users