background image

WELCOME TO THE SPA LIFE!

Please enjoy your new Everyday Hot Tub, but think
safety first. Read your Owner’s Manual in its entirety
before installing your spa and encourage all spa
users to do the same. More than just common
sense, this Owner’s Manual provides vital safety and
operational information.

We sincerely hope your spa life is a pleasant experi-
ence. If problems should arise, contact your Every-
day Hot Tubs™ dealer. Or contact Marquis Corp. at
any of the following:

Voice: (503)838-0888, (800)275-0888
Email: [email protected]
Web: www.marquisspas.com

Marquis Corp.
596 Hoffman Road
Independence, OR 97351

owner’s manual

1

get into it!

Содержание 210

Страница 1: ...mon sense this Owner s Manual provides vital safety and operational information We sincerely hope your spa life is a pleasant experi ence If problems should arise contact your Every day Hot Tubs dealer Or contact Marquis Corp at any of the following Voice 503 838 0888 800 275 0888 Email service marquiscorp com Web www marquisspas com Marquis Corp 596 Hoffman Road Independence OR 97351 owner s manu...

Страница 2: ...or ___________________________________ Spa Serial ________________________________________ Pack Serial _______________________________________ Dealer s Name _____________________________________ Dealer s Address ___________________________________ City _______________________State____Zip Code________ Telephone ___________________________________________ Every effort has been made to ensure the acc...

Страница 3: ...ion 10 11 Filter Cartridge 12 Electrical Requirements 13 STARTING YOUR SPA 14 15 OPERATING YOUR SPA 16 SPA SPEFICATIONS 530 17 415 18 210 19 SPA CONTROL OPERATION 530 415 210 20 23 EQUIPMENT DIAGRAM 530 24 415 210 25 TROUBLESHOOTING 26 27 LCD Diagnostic Messages 27 MAINTENANCE 28 31 SPA CARE AND ENJOYMENT GUIDE 32 40 LIMITED WARRANTY 41 43 owner s manual index 3 ...

Страница 4: ...A ground terminal pressure wire connector is provided on the surface of the control box inside the equipment compartment This connector should be bonded with a minimum No 8 AWG 8 4mm2 solid copper wire between this unit and any metal ladders metal water pipes metal enclosures of electrical equipment conduit or metal equipment within five feet 1 5m of the spa If the spa is located on a reinforced c...

Страница 5: ... an electric shock Disconnect the power until the fault has been identified and corrected ALL SPA MODELS 11 Install the spa so proper drainage is provided 12 DANGER RISK OF ELECTRIC SHOCK Install the spa at least five feet 1 5m away from metal surfaces in accordance with the National Electric Code ANS NMFPA70 1993 Each metal surface must be permanently connected to a minimum No 8 8 42mm2 solid cop...

Страница 6: ... Safety Covers Always lock the child resistant locks after using the spa for your children s safety 18 SAVE THESE INSTRUCTIONS WARNING Children should not use spas or hot tubs without adult supervision WARNING Do not use spas or hot tubs unless all suction guard s are installed to prevent body and hair entrapment WARNING Do not use drugs or alcohol before or during the use of a spa or hot tub to a...

Страница 7: ... consommation d alcool ou de drogue augmente considérablement les risques d hyperthermie motrelle dans une cuve de relaxation AVERTISSEMENT Avant d utiliser une cuve de relaxation mesurer la température de l eau l aide d un thermométre précis AVERTISSEMENT Il peut être dangereux pour la santé de se plonger dans de l eau plus de 40 C AVERTISSEMENT L utilisation prolongée d une cuve de relaxation pe...

Страница 8: ...ure to perceive heat failure to recognize the need to exit the spa physical inability to exit the spa fetal damage in pregnant women and unconsciousness resulting in a danger of drowning WARNING The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Persons taking medications which induce drowsiness such as tranquil izers antihistamines or a...

Страница 9: ...ormance of the hydrotherapy jets limits the flow or trips the high limit thermostat which will turn off the entire spa PERSONAL SAFETY DO NOTs Don t use the spa with the equipment compartment door removed Don t use the spa for more than 10 minutes of time at water temperatures in excess of 102 F 39 C Don t allow the jet pump to operate for an extended period of time with the cover in place Extende...

Страница 10: ...t the weight of the filled spa Locate the equipment compartment where it will be accessible Your spa MUST be installed to permit access for servicing the equipment above and or below any decks or floors Access is essential and must allow adequate room for service Leave access to the circuit breakers in the sub panel 240V models or to the interrupter switch GFCI 120V models on the end of the power ...

Страница 11: ... level on this surface thus it s important to get it onto a solid foundation as soon as possible DECK INSTALLATION Be sure the deck can support the weight of your filled spa by checking the deck s maximum load capacity Consult a qualified building contractor or structural engineer Minimum requirement is 100 pounds per square foot INDOOR INSTALLATION There are special requirements if you place your...

Страница 12: ... the case of extended hot weather the spa water temperature may reach and maintain 104 F to 106 F 40 C to 41 C or higher This is due to the ambient temperature and the full insulation in the spa cabinet You may have the option of shorten ing the pump run time See SPA CONTROL OPERATION for available options FILTER CARTRIDGE Your portable spa is equipped with the Constant Clean Filtration system NOT...

Страница 13: ...ner to ensure that all electrical connections are made in accordance with all electrical codes in effect at the time of installation 120 Volt 120V units must only be connected to a properly grounded grounding type 15 amp dedicated receptacle 120V equipment is designed to operate on 60Hz alternating current only at a voltage of 120 12 5 amp maximum load Only use the cord provided with the spa do no...

Страница 14: ...PORTANT for your safety and the longevity of your spa THERAPY PUMP Allow the spa to circulate on high speed see SPA CONTROL OPERATION for four to five minutes to discharge air from the plumbing system Do not expect hot water immediately from the jets the heater will take several hours to heat the water Start up procedure 1 Place spa on a hard flat level surface Make sure the power supply is off 2 ...

Страница 15: ...per hour for 240V systems SPA COVER When the spa is not in use the spa cover should be kept on the spa to retain the water s heat and to keep out dirt leaves etc Your heater maintains a constant water temperature between uses For your safety and convenience the cover is equipped with adjustable straps safety locks and handles Use the exterior handles to remove and replace your cover We suggest tha...

Страница 16: ... four tabs POWER SWIRL JET This rotating jet provides a firm broad area of circular massage The water flow can be adjusted by turning the jet face using the four tabs CASCADE NECK JETS The Cascade Neck jets are turned on and off when the jet pump is on using the small teardrop neck jet control lever CASCADE NECK JET CONTROL Use this control to increase or decrease the air flow to the Cascade Neck ...

Страница 17: ...Floor Drain 1 10 Light 1 11 Cascade Neck Jet Valve 1 Physical Specifications Size Dimensions 84 x 84 Height 34 Interior Depth 33 Seating Positions 5 Weight Dry Lbs 720 Weight Full Lbs 3639 Water Capacity Gallons 350 Total Therapy Jets 30 the 530 Use the Bather s panel to set the temperature select the filtration and turn on the jets and lights This valve controls the water flow of the Cascade Neck...

Страница 18: ...oor Drain 1 10 Light 1 11 Cascade Neck Jet Valve 1 Physical Specifications Size Dimensions 77 x 77 Height 34 Interior Depth 32 5 Seating Positions 5 Weight Dry Lbs 475 Weight Full Lbs 2977 Water Capacity Gallons 300 Total Therapy Jets 15 the 415 Use the Bather s panel to set the temperature select the filtration and turn on the jets and lights This valve controls the water flow of the Cascade Neck...

Страница 19: ...ittings 2 6 Floor Drain 1 7 Light 1 Physical Specifications Size Dimensions 68 x 68 Height 29 5 Interior Depth 28 Seating Positions 3 Weight Dry Lbs 300 Weight Full Lbs 1545 Water Capacity Gallons 150 Total Therapy Jets 10 the 210 Use the Bather s panel to set the temperature select the filtration and turn on the jets and lights 2 19 ...

Страница 20: ...rd press of the JET pad turns jets off for all quiet mode Fourth press of the JET pad turns pump back to low speed If the pump is already on low heating filter cycle then the first press starts the soak timer After running on low or high speed for 15 min utes the pump automatically turns off unless in heating or filtering cycle SOAK TIMER AND SOAK FEATURE The soak timer starts the first time you p...

Страница 21: ...s to light see MAINTENANCE Every Three to Four Months A good time to do this is every three months when you drain and fill your spa CONSTANT CLEAN FILTRATION Your spa is preset at the factory with a default setting to filter itself using the jet pump on low speed for two hours twice in a 24 hour period These settings represent the filter settings neces sary for average use The timing of the first ...

Страница 22: ...h a default setting to filter for one hour 1H every time your spa is used This filtration cycle begins 30 minutes after the spa light or jet pump has been deactivated The pump runs on low speed to filter the water for the cycle s duration Selectable Smart Logic Settings 1H 1 hour 2H 2 hours 3H 3 hours 4H 4 hours OH Off To adjust the Smart Logic settings Use the TEMP pad to scroll through options W...

Страница 23: ...ever the thermostat calls for heat SYSTEM LOCK Once you find and establish the settings that work best for your individual needs use system lock to keep from inadvertently changing the settings Press the TEMP pad and then immediately press the SETTINGS pad Unlock by repeating sequence While the system is locked you may still operate the jets and light The LCD window dis plays LC to indicate the sy...

Страница 24: ...650 0571 1 2 MP130 pump 630 6077 1 3 HP130 pump 630 6078 1 4 Slice valves 350 6225 2 5 Pump unions 600 0878 4 6 Freeze line 630 2017 1 7 Motor mounts 630 6113 8 8 Hose bib drain 610 0629 1 9 Light bulb 740 0640 1 10 Ozone ready fitting 310 0182 1 equipment diagram 24 ...

Страница 25: ...r 650 0535 1 2 HP120 pump 630 6085 1 3 Slice valves 350 6225 2 4 GFCI cord 740 0569 1 5 Pump unions 600 0878 2 6 Pump plug 630 0460 1 7 Motor mounts 630 6113 4 8 Hose bib drain 610 0629 1 9 Light bulb 740 0640 1 10 Ozone ready fitting 310 0182 1 equipment diagram 25 10 ...

Страница 26: ...power cord INADEQUATE JET ACTION Be sure the shut off valves are completely open Open the jets by turning the jet face to allow for maximum water flow Check for obstruction or restrictions at suction guard s or filters such as leaves etc NO HEAT Check temperature displayed in the LCD window for desired temperature setting Inspect the filter cartridge for dirt and debris Check that the water is at ...

Страница 27: ... a condition DO NOT ENTER THE WATER Turn off all power to the spa and contact your dealer for service Sev eral conditions could lead to overheating for example low water level shut off valves closed while heater is on dirty filter and restriction in the plumbing lines After the power if turned back on the spa will not restart itself until the water tem perature within the spa drops to a lower pred...

Страница 28: ...eposits does not trap particles properly The Maintenance Reminder on the spa side Control Panel indicates a CL every 30 days to remind you to clean your filter Removing the Filter Grasp the edge of the dome shaped Vortex filter top pull up firmly but gently to remove it Turn the filter cartridge counterclockwise to unscrew it from its base Lift out the filter cartridge Use a hose to clean the filt...

Страница 29: ... reminder appears on the control panel as CH to remind you to change water More frequent draining may be required depending on use 1 Leakage Detection Open the equipment door and check for signs of water leakage around the pump Pump seals wear out over time especially with improper water chemistry Early detection of pump seal failure can significantly reduce repair costs 2 Ozonator Option Operatio...

Страница 30: ...at of preservative for maximum weather protection Your dealer can suggest the best preservative for your environment 4 Excess Debris Grit and debris tracked into the spa should be removed with a spa vacuum 5 Water Line To avoid buildup of oils and lotions at the water line clean the interior when needed We sug gest the DuraMitt to clean without scratching NOTE Do not use the same brush or mitt to ...

Страница 31: ...1 Turn off the power to the spa 2 Drain the spa See DRAINING AND REFILLING THE SPA 3 Remove all residual water from the seating and footwell If necessary bail out the remaining water then dry the spa with towels A wet dry vacuum is recommended for best results 4 Using the wet dry vacuum place vacuum nozzle over each jet nozzle to remove water from plumbing lines starting with the highest jet and f...

Страница 32: ... and combustible materials 6 Keep chemicals away from open flame or other heat source Do not smoke near chemicals If a dry chlorine chemical fire should occur use water only Do not use a dry chemical fire extinguisher to attempt to put out the fire 7 When adding chemicals always keep the water circulating in the spa with jets in a downward circular pattern for better chemical distribution Add chem...

Страница 33: ...e Sanitizing Methods The use of an ozonator option greatly reduces the amount of chemical sanitizer you need in the water Ozone works by delivering activated oxygen gas into the spa water via an ozone injector fitting The ozone gas combines with contaminants to sanitize the water Although sometimes promoted as a stand alone chemical free alternative we recommend that you maintain a small residual ...

Страница 34: ...nce bacteria and other wastes are neutralized by the sanitizer they stay in the water unless oxidized or shocked Often called chloramines or bromamines they create dull cloudy water and can cause odor and eye or skin irritation Shock Treatment rids your spa of these wastes for clear sparkling water Shocking is recommended once a week or whenever the water appears dull or cloudy or has a strong chl...

Страница 35: ...ore balancing the pH The product s you should use to adjust pH and or alkalinity are pH Alkalinity Increase or pH Alkalinity Decrease Make any chemical addi tions per the directions on the bottle and then test and repeat if necessary until all readings are in the desired range 4 After pH and alkalinity levels are in the recom mended range you can establish a sanitizer residual of 0 5 ppm Add one h...

Страница 36: ...ness Increase It is critical to have some calcium in your water however the level of calcium should be between 200 400 ppm High calcium levels can cause scale buildup on spa surfaces and equipment Your spa is protected against high calcium by using Metal Stain Control when initially filling your spa Low calcium levels can cause spa water to be come highly corrosive and damaging to the spa equipmen...

Страница 37: ...and creates an immediate sanitizer level when added to the spa Marquis SpaCare Chlorine can be used in conjunction with the Marquis Ozone System Bromine Concentrate For a different sanitizing option bromine tablets are slowly dispensed into the spa via an adjust able floating bromine dispenser When using bromine in conjunction with the ozone system you should maintain a level of 0 5 ppm As a stand...

Страница 38: ... the spa filter and create cloudy water The use of Clarifier combines these microscopic particles into larger particles that can be trapped in the filter to clear cloudy water Foam Eliminator If foam appears in your spa the action of the jets will keep it from dissipating The use of Foam Eliminator instantly rids your spa water of foam Spa Perfect This natural enzyme breaks down body oils and loti...

Страница 39: ...oo many chloramines bromamines in the water S Treat water with Shock then adjust sanitizer level as necessary MUSTY ODOR C Not enough sanitizer in water bacteria or algae in water S Add sanitizer as necessary and shock Read just sanitizer level if necessary YELLOW WATER C Low pH S Adjust pH with pH and Alkalinity Increase FOAMING C High concentration of body oils lotions or soaps as well as high t...

Страница 40: ...ZER IN THE WATER C Too much chlorine or bromine added or dispensed into the spa S Remove spa cover and activate jets and air control Allow jets to run for 30 minutes Test water with a Water Test Strip to see if desired level has been reached EYE OR SKIN IRRITATION C Contaminants or excessive amount of chloramines bromamines in water S Treat water with Shock Adjust sanitizer level C pH level is low...

Страница 41: ...nst leaking for three years MAJOR COMPONENTS AND SYSTEMS Marquis Corp warrants the heater jet pump pump seal controls and equipment pack against any malfunction or defect in materials or workmanship for a period of three years from date of purchase FACTORY INSTALLED PARTS Marquis Corp warrants all factory installed spa parts system and components including drain bib GFCI cord gaskets fuses remov a...

Страница 42: ...ulbs skimmer lids removable jet fittings covers and cover locks and latches should be returned by the customer to the authorized Everyday Hot Tubs dealer for replacement Your authorized Everyday Hot Tubs dealer reserves the right to assess travel charges for service calls which are be yond the scope of its normal service area INVALIDATION OF WARRANTY This warranty is void if this Everyday Hot Tub ...

Страница 43: ...lectrical connections accidents failure to follow procedures defined in the Everyday Hot Tubs Owner s Manual cleaning agents and lightning and other natural occurrences IMPORTANT Some states do not allow the exclusion or limitation of incidental or consequential damages therefore the above limitations or exclusions may not apply to you DISCLAIMERS There are no additional warranties expressed or im...

Отзывы: