background image

 

SAFETY INSTRUCTIONS

 

 

 

TO AVOID SEVERE PERSONAL INJURY OR PROPERTY DAMAGE 

 

BEFORE  OPERATING  THIS  TOOL,  ALL  OPERATORS  SHOULD  READ  AND  STUDY  THIS  MANUAL 
TO  UNDERSTAND  AND  FOLLOW  THE  SAFETY  WARNINGS  AND  INSTRUCTIONS.  FAILURE  TO 
FOLLOW  WARNINGS  COULD  RESULT  IN  DEATH  OR  SERIOUS  INJURY.  KEEP  THESE 
INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE. 

 

SAFETY INSTRUCTIONS: 

 

EYE PROTECTION which conforms to ANSI/CE specifications and provides protection against flying 
particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the 
work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is 
required to guard against flying fasteners and debris, which could cause severe eye injury. 
The  employer  and/or  user  must  ensure  that  proper  eye  protection  is  worn.  Eye  protection 
equipment must conform to the requirements of the ANSI  Z87.1  and  89/686/EEC  and  provide  both 
frontal  and  side  protection.  NOTE:  Non-side  shielded  spectacles  and  face  shields  alone  do  not 
provide adequate protection. 

 

CAUTION:  Additional  Safety  Protection  will  be  required  in  some  environments.  For example,  the 
working area may include exposure to noise level which can lead to hearing damage. The employer 
and user must ensure that any necessary hearing protection is provided and used by the operator 
and others in the work area. Some environments will require the use of head protection equipment. 
When required, the employer and user must ensure that head protection conforming to ANSI Z89.1/ 
CE is used. 
 
AIR  SUPPLY  AND  CONNECTIONS 
Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may 
explode possibly causing injury. 
 
Do  not  use  supply  sources  which  can  potentially  exceed  200  p.s.i. (14  kg/cm

2

).  as  tool  may  burst, 

possibly causing injury. 
 
The  connector  on  the  tool  must  not  hold  pressure  when  air  supply  is  disconnected.  If  a wrong 
fitting is used, the tool can remain charged with air after disconnecting and thus will be able to drive 
a fastener even after the air line is disconnected, possibly causing injury. 
 
Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle, 
possibly causing injury. 
 
Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool; 3.) When 
clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work area, as accidental 
actuation may occur, possibly causing injury. 
 
NAIL LOADING 
When loading tool:  1.) Never place a hand or any part of body in fastener discharge area of tool;  2.) 
Never  point  tool  at  anyone;  3.)  Do  not  pull  the  trigger  or  depress  the  trip  as accidental actuation 
may occur, possibly causing injury. 

 

OPERATION 
Always handle the tool with care:  1.) Never engage in horseplay;  2.) Never pull the trigger unless 
nose  is  directed  toward  the  work;  3.)  Keep  others  a  safe  distance  from  the  tool  while  tool  is  in 
operation as accidental actuation may occur, possibly causing injury. 
 
The operator must not hold the trigger pulled on contact arm tools except during fastening operation 
as serious injury could result if the trip accidentally contacts someone or something, causing the 
tool to cycle. 
 
Keep  hands  and  body  away  from  the  discharge  area  of  the  tool.  A contact  arm  tool  may bounce 
from  the  recoil  of  driving  a  fastener  and  an  unwanted  second  fastener  may  be driven, possibly 
causing injury. 
 
Check  operation  of  the  contact-arm  mechanism  frequently.  Do  not  use  the  tool  if  the  arm  is not 
working correctly as accidental driving of a fastener may result.  Do not interfere with  the  proper 
operation of the contact-arm mechanism. 
 
Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may 
cause deflection of fasteners which could cause injury. 
 
Do  not  drive  fasteners  close  to  the  edge  of  the  work  piece  as  the  wood  may  split,  allowing  the 
fastener to be deflected possibly causing injury. 

 

MAINTAINING THE TOOL 

When  working  on  air  tools,  note  the  warnings  in  this  manual  and  use  extra  care  when  evaluating 
problem tools.

 

 
 

Содержание PN57 Series

Страница 1: ...ANUAL CE DECLARATION OF CONFORMITY 19 3 19 Everwin Pneumatic Corp BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIO...

Страница 2: ...TE Additional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use E...

Страница 3: ...eals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenanc...

Страница 4: ...ad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserkl ring CE Deklaration DANSK EVERWIN PNEUMATIC CORP erkl rer herved at p...

Страница 5: ...sed the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress co...

Страница 6: ...ssure within this range for best fastener performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE TECHNICAL DATA AIR CONSUMPTION Tool air consumption PN57 B 2 1 cfm 1 0 liter second PN57HD B 2 8...

Страница 7: ...entionally allowed to recontact the work surface with the trigger still actuated finger still holding trigger pulled an unwanted second fastener will be driven SEQUENTIAL TRIP IDENTIFIED BY NICKEL PLA...

Страница 8: ...r in pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept c...

Страница 9: ...harge area of tool while the air supply is connected l Never point the tool at anyone else l Never engage in horseplay l Never pull the trigger unless nose is directed at the work l Always handle the...

Страница 10: ...er Do not press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fastener Remove your finger from the trigger after each oper...

Страница 11: ...r press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION l Use this pn...

Страница 12: ...problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full vo...

Отзывы: