Page - 35
4.16.2. Fault Severity
This section allows the user to enable (
warn
) or disable
(discard)
fault for several CDP errors, including:
Error timecode, error service info, time missing, CC data missing, count seq discontinue, error CDP ID, error
CDP length, error checksum, error framerate, count bad.
4.17. TRANSLATOR
WebEASY
®
- Translator
4.17.1. 608 to 708
Global Enable:
Used to control global 608 to 708 translator enable, or to enable only for specific GPI.
4.17.2. Service Mapping
(For CC1-CC4 and TXT1-TXT4)
This parameter is used to control translator 608 to 708 service mapping.
Figure 4-45: Service Mapping