9821EMR-AG-HUB  

User Manual 

 

Page - 8

 

Revision 0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This page left intentionally blank 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 9821EMR-AG-HUB

Страница 1: ...e 9821EMR AG HUB product Evertz Microsystems expressly prohibits the use of this guide for any purpose other than the operation of the contained in this reference guide consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 9821EMR AG HUB product Due to on going research and development features and specifications in this manual ...

Страница 2: ...This page left intentionally blank ...

Страница 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Страница 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Страница 5: ...rt Monitor 11 4 1 4 SFP Control 12 4 1 5 Genlock Control 12 4 1 6 In band Control 13 4 1 7 RPC Timeout 13 4 1 8 Time Management 13 4 1 9 Card Control 13 4 2 PRODUCT FEATURES 13 4 2 1 Product Features 13 4 2 2 License Control 13 4 3 CROSSPOINT CONTROL 14 4 3 1 Configuration Guide 14 4 3 2 Crosspoint Control 15 4 4 SIGNAL INPUT 20 4 4 1 Global Control 20 4 4 2 Link Monitoring 20 4 4 3 Channel Monito...

Страница 6: ...rol 26 4 8 2 Express IP Input 26 4 8 3 IP Input Control 27 4 9 SIGNAL OUTPUT 27 4 9 1 Output Control 27 4 9 2 Channel Monitoring 27 4 10 DEALY CONTROL 28 4 10 1 Global Delay Control 28 4 11 PCR CONTROL 29 4 11 1 PCR Output Control 29 4 11 2 PCR Input Control 29 4 11 3 Time Reference 30 4 12 PTP CONTROL 30 4 12 1 PTP Control 30 4 12 2 PTP Monitor 30 4 13 REFERENCE NOTIFY 31 4 13 1 Reference Notify ...

Страница 7: ...Guide 14 Figure 4 7 Configuration Guide Diagram 15 Figure 4 8 WebEASY Crosspoint Control Dante to Dante IP and TDM 16 Figure 4 9 WebEASY Crosspoint Control IP to DANTE IP and TDM MADI 16 Figure 4 10 WebEASY Crosspoint Control TDM to Dante IP and TDM MADI 17 Figure 4 11 WebEASY Crosspoint Control Dante TDM 18 Figure 4 12 WebEASY Crosspoint Control AES67 S302M Dante 18 Figure 4 13 WebEASY Crosspoint...

Страница 8: ...Configuration 38 Figure 5 9 WebEASY 9821EMR FC Module Configuration 39 Figure 5 10 WebEASY 9821EMR FC Dante Module Information 40 Figure 5 11 WebEASY 9821EMR FC Dante TDM In and Out Status 41 Figure 6 1 WebEASY 9821EMR AG HUB Top Menu Bar 43 Figure 6 2 WebEASY 9821EMR AG HUB Firmware Upgrade 43 Figure 6 3 WebEASY 9821EMR FC Top Menu Bar 43 Figure 6 4 WebEASY 9821EMR IO DANTE 64 Firmware Upgrade 44...

Страница 9: ...9821EMR AG HUB User Manual TABLE OF CONTENTS Revision 0 1 Page v This page left intentionally blank ...

Страница 10: ...y offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this reference guide no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken i...

Страница 11: ...9821EMR AG HUB User Manual TABLE OF CONTENTS Revision 0 1 Page vii This page left intentionally blank ...

Страница 12: ......

Страница 13: ...he existing Evertz TDM enabled Audio interfaces It has a number of functional use cases including translating between AoIP standards including SMPTE ST 302M AES67 and Dante for audio bridging between devices supporting SMPTE ST 302M or AES67 to a common core IP audio format AES67 to AES67 for profile grooming Bulk audio connection between audio systems such as connecting multiple mobile broadcast ...

Страница 14: ...9821EMR AG HUB User Manual Page 2 Revision 0 1 This page left intentionally blank ...

Страница 15: ...FP cages for mini din or fiber SFPs Number 4 Two SFP cages for Main and Backup Q SFPs Number 5 Top FC for 9821EMR AG HUB communication and upgrade Number 6 Bottom FC for Dante modules communications and upgrade Number 7 Main and backup PSUs 2 2 REAR PANEL Figure 2 2 9821EMR AG HUB Rear Panel Connections Number 8 Main and backup optional power supplies Number 9 Top FC Ethernet port Number 10 Bottom...

Страница 16: ... each cage represent the following o B TDM MADI input o A TDM MADI output Number represents the TDM MADI ports 1 10 o SFPs 11 18 are for future use Connect TDM inputs B from 9821 to TDM output of ADMX Connect TDM outputs A from 9821 to TDM input of ADMX There is no redundancy for TDM or MADI connection 2 3 1 2 Q SFPs There are two Q SFPs top is the main and bottom is the backup These SFPs are used...

Страница 17: ...9821EMR AG HUB User Manual Revision 0 1 Page 5 For version above 67 the mapping is one to one ...

Страница 18: ...te I O Usually all primary Dante s are connected to one common switch and secondary Dante are connected to a second common switch These two switches are isolated from control network and only PC with Dante Controller software needs to have access to them 2 3 2 2 Power There are two power connections as main and backup 2 3 2 3 Ethernet There are two Ethernet ports between the two power connectors T...

Страница 19: ...tion to the com that appears after the above connection Speed 115200 Data 8 bit Parity None Stop Bits 1 bit Flow Control None Login as customer customer and set the IP To set the bottom FC IP connect the Micro USB to the bottom FC and open Teraterm Login as root evertz and then type console and from there change the IPs Once the IP on both FCs are configured reboot the entire unit for the changes ...

Страница 20: ...9821EMR AG HUB User Manual Page 8 Revision 0 1 This page left intentionally blank ...

Страница 21: ...ccess the Webeasy page simply type the IP address of the control port of 9821EMR AG HUB module in the web browser s address bar on your PC which is on management network Figure 4 1 WebEASY Login Menu Login and password is customer or root evertz On the web interface there are different types of menus highlighted in Figure 4 2 Figure 4 2 WebEASY 9821EMR AG HUB Main Menu ...

Страница 22: ...ol IP address FC of the unit 4 1 2 Data Port Configuration This section allows the user to configure the Data Port IP addresses of the unit for in band communication QSFP 1 1 and QSFP 1 2 are the main SFPs for S302M and QSFP 2 1 and QSFP 2 2 are the backup SFPs for S302M QSFP 1 3 and QSFP 1 4 are the main SFPs for AES67 and QSFP 2 3 and QSFP 2 4 are the backup SFPs for AES67 ...

Страница 23: ... Frames This parameter displays the number of Multicast Frames received Ethernet Tx Bandwidth This parameter displays the Transmitted Ethernet Bandwidth in Mbps Ethernet Tx Frames Ok This parameter displays the number of Error free Frames Transmitted Ethernet Tx Frames Err This parameter displays the number of Erroneous Frames Transmitted Ethernet Tx Broadcast Frames This parameter displays the nu...

Страница 24: ...e user can select between reference 1 or 2 Currently only reference 1 is active Reference Selection This parameter allows the user to select the reference from REF1 or REF2 Genlock Status This parameter displays if the selected reference is Locked or Unlocked Genlock Present This parameter displays if the selected reference is Present or Absent Genlock Standard This parameter displays the standard...

Страница 25: ...t receive multicast IP address Tally Multicast IP This field allows the user to set tally multicast IP address 4 1 7 RPC Timeout RPC Timeout This field allows the user to set the RPC timeout 4 1 8 Time Management This section allows the user to select the time source which can be local or NTP server 4 1 9 Card Control This section allows the user to set the card Alias purge the card load factory c...

Страница 26: ...ASY Crosspoint Control Configurable Guide Figure 4 7 shows the signal follow from and to the unit If the signal flow is from Dante to TDM or vice versa the TDM input and output status will not report under signal input and signal output Whenever the path is going through FPGA then the status will report correctly ...

Страница 27: ...an be routed any output and multiple outputs can have the same input at the same time Label description Modules Dante Links QSFP SFPs Fiber or Din SFPs for TMD or MADI Following are the possible unidirectional routes Dante to Dante Dante to AES67 or S302M Dante to TDM Only 8 Dante modules can be installed in a single 9821 unit When TDM or AES67 S302M is routed to Dante or from Dante only 8 crosspo...

Страница 28: ...e 16 Revision 0 1 Figure 4 8 WebEASY Crosspoint Control Dante to Dante IP and TDM AES67 or S302M to Dante AES67 or S302M to AES67 or S302M AES67 or S302M to TDM MADI Figure 4 9 WebEASY Crosspoint Control IP to DANTE IP and TDM MADI ...

Страница 29: ...ADI to AES67 or S302M TDM to TDM or MADI to MADI Figure 4 10 WebEASY Crosspoint Control TDM to Dante IP and TDM MADI MADI to Dante or Dante to MADI is not currently supported Following are the possible bidirectional routes Dante TDM AES67 S302M Dante AES67 S302M TDM MADI ...

Страница 30: ...9821EMR AG HUB User Manual Page 18 Revision 0 1 Figure 4 11 WebEASY Crosspoint Control Dante TDM Figure 4 12 WebEASY Crosspoint Control AES67 S302M Dante ...

Страница 31: ... TDM MADI The unidirectional routes can be combined to accomplish multi directional routes e g Dante TDM AES67 TDM Dante AES67 To be able to make route to or from 9821 user may need to use both SDVN and CH to accomplish all In CH 9821 needs to be inside EMR container and modeled as different device ...

Страница 32: ...y POP suppression is used for reducing the pop click sound when the audio switch happens in upstream path 4 4 2 Link Monitoring This section allows the user to monitor the link status for TDM or MADI inputs The detection of TDM or MADI is automatically done The link status only works when the routes under Crosspoint Control are set to go through FPGA E g Dante AES67 S302M or TDM MADI AES67 S302M ...

Страница 33: ...hannels over 10 X TDM 512 per TDM or MADI 64 per MADI inputs This section only works when the signal path is going through FPAG 4 5 IP OUTPUT S302M This section shows the output multicast addresses for QSFP 1 1 1 2 Main and 2 1 2 2 Backup All the addresses are set automatically by Magnum SDVN There are total of 10 links and each link carries 128 TS QSFP 1 1 Main and 2 1 Backup are responsible for ...

Страница 34: ...the user to set the Source UDP Port of each TDM Input IP Output Type Of Service This field allows the user to set the ToS if the network doesn t support ToS zero is used as default IP Output Time To Live This field allows the user to set the Time to Live TTL Value 4 6 IP OUTPUT AES67 This section shows the output multicast addresses for QSFP 1 3 1 4 Main and 2 3 2 4 Backup All the addresses are se...

Страница 35: ...low for lower latency but introduce overhead and high packet rates that may overtax some devices or networks Long packet times imply higher latency and require additional buffering which may not be available on memory constrained devices 9821EMR AG HUB supports 1ms and 125µs packet time for AES67 IP Output Mute If PTP is Unlocked This option allows the user to mute AES67 audio output when PTP is n...

Страница 36: ... addresses and UDP ports set for each link 4 6 4 IP Output Advanced Control IP Output Source IP Address This field allows the user to set the Source IP Address of each TDM Input IP Output Source UDP Port This field allows the user to set the Source UDP Port of each TDM Input IP Output Type Of Service This field allows the user to set the TOS if the network doesn t support TOS zero is used as defau...

Страница 37: ...tput path is on QSFP1 1 or QSFP2 1 QSFP1 2 or QSFP2 2 4 7 2 Express IP Input This section allows the user to set the Multicast Address range and Port number for each TDM and Purge it 4 7 3 IP Input Control This field allows the user to see and set the Multicast Address and UDP Port number for each Transport Stream in each TDM link Also it displays the status of the IP Input and RTP Sequence Errors...

Страница 38: ... Input streams use RTP 4 8 IP INPUT AES67 This section allows the user to view or modify some of the information or parameters for AES67 incoming signal Figure 4 18 WebEASY IP Input AES67 4 8 1 Global Control SFP Redundancy Selection This field allows the user to see whether the traffic for IP to TDM Output path is on QSFP1 3 or QSFP2 3 QSFP1 4 or QSFP2 4 4 8 2 Express IP Input This section allows...

Страница 39: ...sence Figure 4 19 WebEASY Signal Output 4 9 1 Output Control User has to select the correct Input source format and output mode based on QSFP port connection and application Source formats can be ST302M QSFP 1 1 2 1 and 1 2 2 2 or AES67 QSFP 1 3 2 3 and 1 4 2 4 and output Mode can be TDM or MADI 4 9 2 Channel Monitoring User can monitor all 512 channel carrier presence in each TDM Outputs User can...

Страница 40: ...ate for compressed streams that typically have a huge POSITIVE offset added to their PTS These PTS values will be far ahead of running PTP so the card cannot sync to it unless incoming timestamps advancement is known In any regular operation this setting has to be set to 0 EMR Delay for Manual Mode This field specifies how much latency we want thru the EMR i e how long we want audio samples to sta...

Страница 41: ...the PCR Multicast Address UDP Port Number This control allows the user to set the port number for UDP traffic RTP Mode This parameter allows the user to Enable Disable the RTP header 4 11 2 PCR Input Control In this section the user can set the main and backup ports and other parameters for incoming PCR PCR PID This parameter allows the user to set the time reference PCR PID IP Address This parame...

Страница 42: ...s can be monitored Figure 4 22 WebEASY PTP Control 4 12 1 PTP Control SFP Port The user needs to select the correct SFP port from which the PTP stream is coming Domain Number This Domain number has to match the PTP source domain number Priority 1 Priority 1 has to match the priority 1 of PTP source or set to 255 for all Priority 2 Priority 2 has to match the priority 2 of PTP source or set to 255 ...

Страница 43: ...if any follow_up request has been lost Delay_Req Shows the number of Delay has been requested Delay_Resp Received Shows the number of Delay has been received Delay_Req and Delay_Resp Receive have to match if it doesn t there is a misconfiguration with PTP route Delay_Resp Lost Shows if any Delay response has been lost 4 13 REFERENCE NOTIFY In this section the user can enable or disable traps for t...

Страница 44: ...trap for PCR Increment Errors to True or False for main and backup path 4 13 3 PTP Notify PTP Present Allows the user to set the trap for PTP Present to True or False PTP Locked Allows the user to set the trap for PTP Locked to True or False PTP Failover Allows the user to set the trap to True or False during PTP Failover PTP Packet Lost Allows the user to set the trap to True or False when there ...

Страница 45: ...Page 33 4 14 NOTIFY In this section the user can set the following Temperature Threshold for trap Set the trap to true or false for Board Temperature Set the trap to True or False for Ethernet and Input Signal Fault Figure 4 24 WebEASY Notify ...

Страница 46: ...9821EMR AG HUB User Manual Page 34 Revision 0 1 4 15 SNMP TRAP In this section the user can view add or remove trap destinations Figure 4 25 WebEASY SNMP Trap ...

Страница 47: ... of the browser The following menus are available on the web easy page Figure 5 1 WebEASY 9821EMR FC Main Menu 5 1 SYSTEM In the section the user can view the Product name Firmware version and Serial number also the Alias name Import Export preset System reboot and Factory reset can be done here Figure 5 2 WebEASY 9821EMR FC System 5 2 NETWORK MANAGEMENT In this section the user can ...

Страница 48: ...gnum Control section is currently not being configured or used Figure 5 3 WebEASY 9821EMR FC Network management 5 3 TIME MANAGEMENT In this section the user can set the time source to local or NTP server The Time Zone offset and DLS can be manually set whether the time source is set to local or NTP Figure 5 4 WebEASY 9821EMR FC Time Management ...

Страница 49: ...ure and supply voltage Channels Status is not currently being used Figure 5 5 WebEASY 9821EMR FC SFP For QSFP there are 2 slots main and backup and each slot provides information about QSFP presence Name Serial number firmware version connector type and Wave length Figure 5 6 WebEASY 9821EMR FC QSFP 5 5 MODULE In this section there are slots for 18 modules but a Dante module occupies two slots and...

Страница 50: ...ot 15 shows status Dante module 8 will occupy slots 16 and 18 but only slot 18 shows status The active slots will show the modules Status Name Serial number Firmware version and Temperature also the user can download and upload each module s config Network Control is not being used currently Figure 5 7 WebEASY 9821EMR FC Module 5 6 MODULE CONFIGURATION In this section the overview of the Dante mod...

Страница 51: ...d redundant Ethernet port for each module Ethernet Port IP Control The user can set the IP address for primary and Secondary Dante modules Once the desired IP is set Enter has to be pressed for the changes to be applied The DHCP can be set to true if there is a DHCP server otherwise it has to be set to False Primary Secondary Ethernet Port Status and Statistic This section provides information on ...

Страница 52: ... 1 Audio Channel XX Output is green it means the Dante Module is receiving Dante from a Dante device and sending it to 9821 as TDM This TDM could be converted to an IP stream or TDM source If TDM2 Audio Channel XX input is green it means 9821 is sends Audio to Dante module as TDM This TDM could be coming from and IP stream or from a TDM source Dante is limited to 64 mono audio input and output cha...

Страница 53: ...9821EMR AG HUB User Manual Revision 0 1 Page 41 Figure 5 11 WebEASY 9821EMR FC Dante TDM In and Out Status ...

Страница 54: ...9821EMR AG HUB User Manual Page 42 Revision 0 1 This page left intentionally blank ...

Страница 55: ...the unit will reboot automatically Figure 6 2 WebEASY 9821EMR AG HUB Firmware Upgrade 6 2 9821EMR IO DANTE 64 UPGRADE To upgrade the EMR IO DANTE 64 the user needs to log as admin admin or root evertz into 9821EMR FC to gain access to upgrade menu Figure 6 3 WebEASY 9821EMR FC Top Menu Bar Once the upgrade option is selected the upgrade page will open and display the installed 9821EMR IO DANTE 64 ...

Страница 56: ...21EMR FC UPGRADE To upgrade the 9821EMR FC the user needs to log as admin admin or root evertz to gain access to upgrade menu Figure 6 5 WebEASY 9821EMR FC Top Menu Bar Once the upgrade option is selected the upgrade page will open and display the installed FC modules Figure 6 6 WebEASY 9821EMR FC Upgrade Link ...

Страница 57: ...ate the 9821EMR FC_XXXVXXXX_BXXX tar gz file Once the file is selected press the Upgrade button The tar gz file will be uploaded and installed and at the end of the upgrade the modules will reboot automatically Figure 6 7 WebEASY 9821EMR FC Firmware Upgrade Once all the modules are upgraded it is recommended to reboot the entire system ...

Страница 58: ...9821EMR AG HUB User Manual Page 46 Revision 0 1 End of Document ...