background image

 

 

Revision 1.0

 Jan 2014

CBV383Z4S-N300

 

 

 DOCSIS 3.0 EMTA/Router with 

Wireless-N

Summary of Contents for CBV383Z4S-N300

Page 1: ...Revision 1 0 Jan 2014 CBV383Z4S N300 DOCSIS 3 0 EMTA Router with Wireless N ...

Page 2: ...d defective must be returned to Seller transportation charges prepaid and will be returned to the Buyer with transportation charges collect unless evaluation proves the item to be defective and that the Seller is responsible for the defect In that case Seller will return to Buyer with transportation charge prepaid Seller may elect to evaluate and repair defective items at the Buyer s site Seller m...

Page 3: ...n the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any i...

Page 4: ... that the Seller is responsible for the defect In that case Seller will return to Buyer with transportation charge prepaid Seller may elect to evaluate and repair defective items at the Buyer s site Seller may charge Buyer a fee including travel expenses if needed to cover the cost of evaluation if the evaluation shows that the items are not defective or that they are defective for reasons beyond ...

Page 5: ...ware Status 8 4 3 BASIC 8 4 3 1 DHCP 8 4 4 ADVANCED 9 4 4 1 Options 9 4 4 2 IP Filtering 11 4 4 3 MAC Filtering 11 4 4 4 Port Filtering 12 4 4 5 Forwarding 12 4 4 6 Port Triggers 13 4 4 7 DMZ Host 14 4 5 FIREWALL 15 4 5 1 Local Log 15 4 6 PARENTAL CONTROL 16 4 7 WIRELESS 17 4 7 1 Radio 17 4 7 2 802 11 Primary Network 17 4 7 3 Access Control 18 4 7 4 Advanced 18 4 7 5 Bridging 19 4 7 6 WMM 19 4 7 7...

Page 6: ......

Page 7: ... most major VoIP Softswitch vendors Call Management systems And it also has voice support that includes hardware based Quality of Service QoS voice compression with popular voice CODES G 711 echo cancellation dynamic latency jitter buffers silence suppression and comfort noise generator 1 1 Features PacketCable 1 5 standard compliant DOCSIS EURODOCSIS 2 0 3 0 standard compliant Support PacketCable...

Page 8: ...e to your equipment Make sure the voltages and frequency of the power outlet matches the electrical rating labels on the AC Adapter Do not place any object on top of the device or force it into a confined space Never push objects of any kind through openings in the casing Dangerous voltages may be present Conductive foreign objects could produce a short circuit that could cause fire electrical sho...

Page 9: ... No DC Power connected DS Green Blinking Downstream scanning On Downstream locked Off Cable interface idle or W DS bonding Orange On W DS locked Off W DS disabled US Green Blinking Upstream scanning On Upstream locked Off Cable interface idle or W US bonding Orange On W US locked Off W US disabled ONLINE Green Blinking CM provisioning On CM On line Off CM Off line LAN Green Blinking Data in traffi...

Page 10: ...ow the steps in the sequence outlined below Failure to do so could result in improper operation or failure of your cable modem Step 1 Connect a cable by feeding the F connector on the back of the cable modem Ensure the center conductor of the 75 ohm coaxial cable is inserted directly into the center of the F connector Secure the coaxial cable by carefully threading the outer shell of the coaxial c...

Page 11: ...he cable modem Exercise carefully to ensure the connectors are properly aligned prior to insertion and ensure the two connectors engage completely The cable modem is shipped with an AC adapter Remember to use only power adapter that came with the cable modem Other power adapters might have voltages that are not correct for your particular cable modem Using a power adapter with the wrong voltage ca...

Page 12: ... network components appears Look for an entry named TCP IP This entry may be followed by an arrow and a description of the NIC hardware device installed in the computer If you don t see TCP IP listed anywhere in the The following network components are installed box click the Add button choose Protocol and click the Add button Select Microsoft as the manufacturer and then scroll down in the list o...

Page 13: ... login to your CBV383Z4S N300 1 Open your web browser You may get an error message This is normal Continue on to the next step 2 Type the default IP address of the CBV383Z4S N300 e g 192 168 0 1 and press Enter 3 The Log In page appears Type the user name admin and your password password in the respective fields There are seven categories in this web management including Status Basic Advanced and ...

Page 14: ... process with your cable service provider If Network Access shows Allowed then your cable service provider has configured the CBV383Z4S N300 to have Internet connectivity If Network Access shows otherwise you may not have Internet access and please contact your cable service provider for assistance 4 3 Basic The Basic page contains the basic features of CBV383Z4S N300 including Setup DHCP and Back...

Page 15: ...ation of DHCP clients including the IP and MAC addresses of each PC Since MAC addresses are unique and permanently fixed into hardware you can identify any PC listed by its MAC address The CBV38Z4C provides leases for 3600 seconds default and has an automatic renewal mechanism that will keep extending a lease as long as the associated PC remains active You can cancel an IP address lease by selecti...

Page 16: ...e When accessing the CBV383Z4S N300 from a remote location you must use HTTP port 8080 and your IP address This is the WAN IP address that appears at the Basic Setup page For example if this IP address were 211 20 15 28 you would navigate to http 211 20 15 28 8080 to reach the CBV383Z4S N300 s Web Management page from a remote location Multicast Enable To enable multicast traffic to pass through b...

Page 17: ...d by the CBV383Z4S N300 To enable IP Filtering feature of CBV383Z4S N300 check the Enable box and click Apply button 4 4 3 MAC Filtering The MAC Filtering page enables you to enter the MAC address of specific PCs on your LAN that you don t permit to have outbound access ability to the WAN These PCs can still communicate with each other through the CBV383Z4S N300 but packets they send to WAN addres...

Page 18: ...ange Then select its protocol form the drop down list and check the Enable box and click Apply button To block only one port set both Start and End ports the same 4 4 5 Forwarding For communications between LAN and WAN the CBV383Z4S N300 normally only allows you to originate an IP connection with a PC on the WAN it will ignore attempts of the WAN PC to originate a connection onto your PC This prot...

Page 19: ...ggers page allows you to configure dynamic triggers to specific devices on the LAN This allows for special applications that require specific port numbers with bi directional traffic to function properly Applications such as video conferencing voice gaming and some messenging program features may require these special settings Port Triggering is an elegant mechanism that does the forwarding for yo...

Page 20: ...is not redirected to another host via the port forwarding feature to the IP address of the host PC This designates one PC on your LAN that should be left accessible to all PCs from the WAN side for all ports For example if you locate a HTTP server on this machine anyone will be able to access that HTTP server by using your CBV383Z4S N300 s IP address as the destination This may be used when proble...

Page 21: ... event log reported via email alert and these attack records are also visible in the table on the bottom of this page Specifies the e mail address and its SMTP of the administrators who should receive notices of any attempted firewall violations Type the addresses in standard Internet e mail address format for example yourname onecompany com Then check the Enable box to enable the alert feature Cl...

Page 22: ...c selections of rules which block certain Internet content and certain Web sites When you change your Parental Control settings you must click on the appropriate Apply Add or Remove button for your new setting to take effect If you refresh your browser s display you will see the currently active settings 4 6 3 Time of Day Access Policy This page allows configuration of time access policies to bloc...

Page 23: ...rol event log reporting 4 7 Wireless 4 7 1 Radio The Wireless Connection Stage Configuration of the Wireless Radio includes current country and channel number 4 7 2 802 11 Primary Network The 802 11 Primary Network allows configuration of the Primary Wireless Network and its security settings ...

Page 24: ...Modem User s Manual 18 4 7 3 Access Control This page allows configuration of the Access Control to the AP as well as on the connected clients 4 7 4 Advanced This page allows configuration of data rates and WiFi thresholds ...

Page 25: ...CBV383Z4S N300 Cable Modem User s Manual 19 4 7 5 Bridging This page allows configuration of WDS features 4 7 6 WMM This page allows configuration of the Wi Fi Multimedia QoS ...

Page 26: ...CBV383Z4S N300 Cable Modem User s Manual 20 4 7 7 Guest Network This page allows configuration of a guest network ...

Page 27: ... User s Manual 21 4 8 MTA Section MTA has 5 sub items which indicate the status of MTA These information can help you to understand the parameters of MTA operation 4 8 1 Status This page displays initialization status of the MTA ...

Page 28: ...on QPSK 8QAM 16QAM 32QAM 64QAM 128QAM 256QAM SCDMA only Symbol Rate TDMA 160K 320K 640K 1280K 2560K 5120Ksym sec S CDMA 1280K 2560K 5120Ksym sec Bandwidth TDMA 200K 400K 800K 1600K 3200K 6400KHz S CDMA 1600K 3200K 6400KHz Output power TDMA QPSK 8 58 dBmV 8 16QAM 8 55 dBmV 32 64QAM 8 54 dBmV S CDMA QPSK 8 16 32 64 128QAM 8 53 dBmV Output Impedance 75 Ohms Table 3 RF Downstream Specification for Eur...

Page 29: ...dBmV 8 16QAM 8 55 dBmV 32 64QAM 8 54 dBmV S CDMA QPSK 8 16 32 64 128QAM 8 53 dBmV Output Impedance 75 Ohms Table 5 Electrical Specification Parameter Measured Value Notes Input Voltage 12VDC 2A Power consumption 9 5W With AC adaptor Table 6 Physical Specification Parameter Value Size 160 mm L x 36mm H x 212 mm W Weight 520g 10g Modem only Table 7 Environmental Specification Parameter Value Operati...

Reviews: