7800/7700 MultiFrame Manual
7812UDXD Series 3G/HD Up/Down/Cross Converter with Simultaneous Dual Format Outputs and AES I/O
Page - 62
Revision 1.1.1
6.17. UTILITIES CONTROL TAB
The
Utilities Control
tab is used to control the presets. The user can configure the
Recall Preset
,
Store
User Preset
, and enable/disable the
Auto Recall Presets
function. This tab also allows for uploading
Sub-Preset files to the module through FTP or SNMP. Sub-Preset files can be loaded one at a time or all
at once using the Sub-Preset multiple load function.
Figure 6-19: Utilities Control Tab
6.17.1. Utilities Control
The 7812UDXD series of converters can manage 10 user presets.
These 10 presets can store the complete set of card controls.
There may be a slight disturbance in the operation of the card while the new preset is
being recalled.