5.
STATUS LEDS
5.1.
MODULE STATUS LEDS –AES8 VERSION AND NON –AES8 VERSIONS
Figure 5-1 depicts status LEDs for the 7812UDX-3G and 7812UDX-AES8-3G series modules. LEDs are
in the same position and perform the same function for all variations of the 7812.
Shaft
Encoder
(not used)
Module
Status
REF
PRESENT
PGM A
PRESENT
PGM B
PRESENT
GRP 1
PRESENT
GRP 2
PRESENT
GRP 3
PRESENT
GRP 4
PRESENT
7812UDX-AES8-3G
AES2
PRES
AES4
PRES
AES6
PRES
AES8
PRES
AES1
PRES
AES3
PRES
AES5
PRES
AES7
PRES
Headphone Out
(not currently
implemented)
7812UDX-AES8-3G
LINK/ACT
10/100
Figure 5-1: Status LEDs
MODULE STATUS:
This Green LED will be On when the module is operating properly.
LOCAL FAULT:
This Red LED will be On when an essential module input is missing or the module
has another fault.
PGM A PRESENT:
The PGM A PRESENT LED will be green when a valid input signal is present on
the PGM A BNC. It will be red when missing an input signal. It will blink between
red and green when an invalid input signal is presented.
PGM B PRESENT:
The PGM B PRESENT LED will be green when a valid input signal is present on
the PGM B BNC. It will be red when missing an input signal. It will blink between
red and green when an invalid input signal is presented.
REF PRESENT:
The REF PRESENT LED will be green when a valid reference signal is present on
the FRAME REF. It will be red when missing a reference signal. It will blink
between red and green when an invalid genlock signal is presented. This LED will
also be red when genlocking is turned off (lock to video).
GRP1 PRESENT:
This LED will be Green when embedded audio Group 1 is present and Red when
embedded audio Group 1 is not present.