7800EMR-HYDRA2
User Manual
Revision 1.0
Page-15
1. Login Client Host with admin/admin and select “interfaces” tab and choose “Quartz”
2. Add Hydra2 with Port “4000” or available Port
Figure 4-10 : MAGNUM Interfaces
3. Add Device under the Devices tab and Add Hydra2 sources and destinations.
4. Go to “Source Availability” Tab and make the sources and destinations available.
5. Once you finish making sources and destination names, Save the changes
6. Go to “Names” Tab and change the names that will update on serial menu of the Hydra2 card
7. Route the Hydra2 card destination to the particular source for Example: Channel1
8. You should be able to view the update names that have come from Magnum in the 7800EMR-
Hydra Module through serially or telnet into the card.
Menu using options:
(3) Audio Configuration
(4) Hydra Module Options
4) View Output sources (This views updated Names from Magnum)
9. Check Calrec should update updated Names from Hydra2 module
Note:
Please be aware that the config transferred to the card can only transfer names with
a length of 10 characters – so if magnum has longer names it will shorten them.
Содержание 7800EMR-HYDRA2
Страница 2: ...This page left intentionally blank ...
Страница 6: ...7800EMR HYDRA2 User Manual Page ii Revision 1 0 ii This page left intentionally blank ...
Страница 12: ...7800EMR HYDRA2 User Manual Page 4 Revision 1 0 This page left intentionally blank ...
Страница 16: ...7800EMR HYDRA2 User Manual Page 8 Revision 1 0 This page left intentionally blank ...
Страница 24: ...7800EMR HYDRA2 User Manual Page 16 Revision 1 0 This page left intentionally blank ...
Страница 26: ...7800EMR HYDRA2 User Manual Page 18 Revision 1 0 This page left intentionally blank ...
Страница 30: ...7800EMR HYDRA2 User Manual Page 22 Revision 1 0 Figure 7 2 Sample FTP Upgrade Window ...