INFORMATION TO USERS IN EUROPE 

 

NOTE 

 

CISPR 22 CLASS A DIGITAL DEVICE OR PERIPHERAL 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to the European Union EMC directive.  These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 
 

 

 

INFORMATION TO USERS IN THE U.S.A. 

 

NOTE 

 

FCC CLASS A DIGITAL DEVICE OR PERIPHERAL 

 

This equipment has been tested and found to comply with the limits for a Class A  digital device, 
pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment.  This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 

 

WARNING 

 

Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s 
authority to operate the equipment. 
 
Use of unshielded plugs or cables may cause radiation interference.  Properly shielded interface 
cables with the shield connected to the chassis ground of the device must be used. 

 
 

 

 

EN60065 

Safety 

 

 

EN504192 2005 

Waste electrical products should not be 

disposed of with household waste. Contact 

your Local Authority for recycling advice 

EN55103-1: 1996 

Emission 

EN55103-2: 1996 

Immunity 

Содержание 7708VB-8-HSE

Страница 1: ...ation that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 7708VB 8 HSE Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 7708VB 8 HSE series products Due to on going research and development features and specifications in this manual are subject to change without notice All rights reserved ...

Страница 2: ...This page left intentionally blank ...

Страница 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Страница 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Страница 5: ... PHYSICAL NUMBER OF SLOTS 8 3 8 COMPLIANCE 8 4 STATUS INDICATORS AND DISPLAYS 9 4 1 STATUS INDICATOR LEDS 10 4 1 1 Input Video Status 10 4 1 2 Output Video Status 10 4 2 DOT MATRIX DISPLAY CARD STATUS AND CONTROLS 11 4 3 TOP LEVEL STATUS MENU STRUCTURE 11 4 3 1 Display of Warning Status Indications 12 4 3 2 Displaying the Input Video Standard 13 4 3 3 Displaying the Output Video Standard 14 4 3 4 ...

Страница 6: ...lling the Orientation Card Edge Display Text 22 4 4 10 Controlling the Factory Reset 22 5 JUMPERS AND LOCAL CONTROLS 23 5 1 SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME STATUS 23 5 2 CONFIGURING THE MODULE FOR FIRMWARE UPGRADES 24 6 VISTALINK REMOTE MONITORING CONTROL 25 6 1 WHAT IS VISTALINK 25 6 2 GENERAL 26 6 3 INPUT VIDEO CONTROL 28 6 4 OUTPUT VIDEO CONTROL 29 6 5 INPUT...

Страница 7: ...ab 26 Figure 6 2 New Password Window 26 Figure 6 3 Input Video Control Tab 28 Figure 6 4 Output Video Control Tab 29 Figure 6 5 Input Output Video Control Tab 29 Figure 6 6 Input Video Status Tab 30 Figure 6 7 Output Video Status Tab 30 Figure 6 8 Channel 1 and 2 Faults Tab 31 Figure 6 9 Channel 3 and 4 Faults Tab 32 Figure 6 10 Channel 5 and 6 Faults Tab 33 Figure 6 11 Channel 7 and 8 Faults Tab ...

Страница 8: ...7708VB 8 HSE User Manual 8 SDI ASI or 6 HD SDI plus Ethernet Fiber Transceiver Page iv Revision 0 1 This page left intentionally blank ...

Страница 9: ...essed or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless s...

Страница 10: ...7708VB 8 HSE User Manual 8 SDI ASI or 6 HD SDI plus Ethernet Fiber Transceiver Page vi Revision 0 1 This page left intentionally blank ...

Страница 11: ...bedded AES or any other data in the horizontal or vertical ancillary data space Fully hot swappable from front of frame Supports single mode fiber optic cable Optical output wavelengths of 1310nm 1550nm and up to eight CWDM wavelengths 1470nm 1610nm DWDM wavelength ITU T G 694 1 compliant support Pluggable Evertz XFP module permits wavelength swapping sparing Comprehensive signal and card status m...

Страница 12: ...7708VB 8 HSE User Manual 8 SDI ASI or 6 HD SDI plus Ethernet Fiber Transceiver Page 2 Revision 0 1 Figure 1 1 7708VB 8 HSE Block Diagram ...

Страница 13: ...7708VB 8 HSESeries User Manual 8 SDI ASI or 6 HD SDI plus Ethernet Fiber Transceiver Revision 0 1 Page 3 2 GETTING STARTED 2 1 REAR PLATE DESCRIPTION Figure 2 1 7708VB 8 HSE Rear Plate ...

Страница 14: ...for HD SDI SDI SDTi or DVB ASI SDI OUTPUTS Two BNC outputs for SDI SDTi or DVB ASI The channel 8 output is a selectable monitor output that additionally supports HD SDI see section 4 2 2 1 2 SFP Connection FIBER IN OUT Pluggable XFP fiber module with standard LC Duplex connector This module permits wavelength swapping sparing When inserting an XFP ensure that the main board remains properly seated...

Страница 15: ...y and performed only by qualified Evertz technical personnel 2 2 3 Labeling Certification and Identification labels are combined into one label As there is not enough room on the product to place the label it is reproduced here in the manuals There is no date of manufacture on this label as it can be traced by the bar code label placed on the printed circuit board of each Evertz plug in module Fig...

Страница 16: ...face of an optical fiber The transmission characteristics of the fiber are dependent on the shape of the optical core and therefore care must be taken to prevent fiber damage due to heavy objects or abrupt fiber bending Evertz recommends that you maintain a minimum bending radius of 5 cm to avoid fiber bending loss that will decrease the maximum attainable distance of the fiber cable For further i...

Страница 17: ...C DVB ASI SMPTE 305M SDTi Number of Outputs 8 output 8 is selectable as an output or monitor port Connector BNC per IEC 61169 8 Annex A Signal Level 800mV nominal DC Offset 0V 0 5V Rise and Fall Time 900ps nominal 270Mb s 270PS 1 485G bs Overshoot 10 of amplitude Return Loss 15dB to 1 5Gb s Alignment Jitter 0 2 UI 3 3 OPTICAL OUTPUT Number of Outputs 1 Connector Female LC Duplex Fiber Size 9μm cor...

Страница 18: ...dard 1dBm High Sensitivity 7dBm Optical Sensitivity Standard 14dBm High Sensitivity 22dBm 3 6 ELECTRICAL Voltage 12V DC Power 20W 3 7 PHYSICAL NUMBER OF SLOTS 350FR 3 7700FR C 3 7800FR 3 3 8 COMPLIANCE Laser Safety Complies with 24 CFR 1040 10 and 1040 11 EMI RFI Complies with FCC regulations for Class A devices Complies with EU EMC directive ...

Страница 19: ...tatus indicators and a 4 digit alphanumeric display on the front card edge to show operational status of the card at a glance The card edge shaft encoder pushbutton is used to select various displays on the alphanumeric display Figure 4 1 shows the locations of the indicators and shaft encoder pushbutton Figure 4 1 Location of Status Indicators Jumpers and Controls ...

Страница 20: ...ion of input video status using the CTRL LED VIN menu selection see section 4 2 GREEN Indicates the presence of a valid input to the corresponding channel YELLOW Indicates that an input to the corresponding channel is denied for one of several possible reasons The STAT VIN menu item for the corresponding channel will report a reason see section 4 2 RED Indicates the detection of video CRC or EDH e...

Страница 21: ...ess the pushbutton This will return to the parameter select menu item you are setting the display shows the parameter name you were setting To change another parameter use the toggle switch to select other parameters If neither the toggle switch nor pushbutton is operated for several seconds the card edge control will exit the menu system and return to an idle state On all menus there is an extra ...

Страница 22: ...t Encoder Menu Level 4 Standards Per Table Indications LOS Loss of Signal RXP Received Power Selections Values from XFP dBm Indications OPTO Optical Status DENY PSWD PSWD Setting SLOT ERR Slot Error Supersedes XFP ERR XFP Error Supersedes LASR ERR Laser Error Supersedes LINK LOS Link Loss Supersedes OK Normal Operation Indications OVER Power Over LOW Power Low NA Not Available 13S 1310nm Standard ...

Страница 23: ... 525I SDTI 1080I 47 96 720P 59 94 625I 1080I 60 STAT LOS Loss of Signal A valid input is not detected DENY FILL Denied due to Capacity Restriction This message may be indicated for one of two reasons 1 The bandwidth of the applied signal may exceed available network capacity as indicated by the STAT NET FILL menu item or 2 The bandwidth of the applied signal may exceed the capacity cap reserve for...

Страница 24: ...nied due to Password Restriction This message is indicated if the output is password protected as configured by the CTRL PSWD menu items DENY MON Denied due to Monitoring Channel Video 8 only This message may be indicated only for Video input 8 when this channel is used as a monitoring channel as configured by the CTRL VID MON menu item UKNOWN Unknown Signal An output is present but the format is ...

Страница 25: ...item STAT The following indications are possible 13S 1310nm Standard Sensitivity XFP option is installed 15S 1550nm Standard Sensitivity XFP option is installed 15H 1550nm High Sensitivity XFP option is installed CXXS CWDM Standard Sensitivity XFP option is installed CXXH CWDM High Sensitivity XFP option is installed DXXS DWDM Standard Sensitivity XFP option is installed DXXH DWDM High Sensitivity...

Страница 26: ...e or absent input It will not include capacity that is dynamically allocated to Ethernet when CTRL NET FILL ETH AUTO is selected Various input signals are allocated network capacity as follows HD SDI Each HD SDI signal will use 16 17 of network capacity SDI Each SDI signal will use 2 94 of network capacity ETHERNET 1G A 1Gbps Ethernet signal will use 13 23 of network capacity ETHERNET 780M A 780Mb...

Страница 27: ...r Password Selections ON Enable Channel OFF Block Channel Selections Selections GEN Output on LOS OFF Output Off BLK Black Active Picture OFF Monitor Off Selections NET Network Control HD 1485Mbps Cap Reserve VID1 6 Only Selections SD 270Mbps Cap Reserve OFF Video Disable Selections VIO1 VIO6 Video In Out 1 6 FILL Capacity Cap Reserve STD Standard Set AUTO Track VOUT Dynamic Changes produce VIN gl...

Страница 28: ...VID menu item then the STD menu item and then choose the desired video channel VIO1 to VIO8 The following selections are available CTRL AUTO Does not restrict the video standard Output will track the corresponding input SET1 Restricts the video input to even rate standards Examples of even rate are those having 60Hz 50Hz 48Hz 30Hz 25Hz or 24Hz field rates plus all SD signals SET2 Restricts the vid...

Страница 29: ...2 VIN3 Output signal received at Video Input 3 VIN4 Output signal received at Video Input 4 VIN5 Output signal received at Video Input 5 VIN6 Output signal received at Video Input 6 VIN7 Output signal received at Video Input 7 VIN8 Output signal received at Video Input 8 VID MON OFF VO1 VO2 VO3 VO4 VO5 VO6 VO7 VIN1 VIN2 VIN3 VIN4 VIN5 VIN6 VIN7 VIN8 Note that while the Video 8 Output is configured...

Страница 30: ...ET menu item then the FILL menu item and then choose the desired video channel VIN1 to VIN8 CTRL The following selections are available AUTO No Cap Reserve Accept Deny corresponding input on a first come serve basis HD Cap Reserve corresponding input at 1485Mbps Video Inputs 1 6 only SD Cap Reserve corresponding input at 270Mbps OFF Disable corresponding input NET FILL VIN1 to VIN8 AUTO HD SD OFF ...

Страница 31: ... relinquished as required for video 1G Bandwidth of 1Gbps reserved for Ethernet Guarantees full bandwidth for Gig E OFF Disable Ethernet NET FILL ETH AUTO 220M 780M 1G OFF Ethernet bandwidth in excess of that assigned will result in full frames dropped Other frames will remain intact The selections 220M and 780M may seem arbitrary however these correspond to increments in available bandwidth with ...

Страница 32: ...following selections are available CTRL HOR Horizontal display for modules housed in 7701FR frame or stand alone enclosure VERT Vertical display for modules housed in 7700FR frame DISP HOR VERT 4 4 10 Controlling the Factory Reset The factory reset can be controlled using menu selections To configure factory reset from the CTRL menu use the shaft encoder pushbutton to select the FRST menu item The...

Страница 33: ...etermines whether local faults as shown by the Local Fault indicator will be connected to the 7700FR frame s global status bus FRAME STATUS To monitor faults on the 7708VB 8 with the frame status indicators on the Power Supply FRAME STATUS LEDs and on the frame s Fault Tally output install this jumper in the ON position default When this jumper is installed in the OFF position local faults on this...

Страница 34: ...upgrade the 7708VB 8 s firmware begin by pulling it out of the frame Move the UPGRADE jumper into the UPGRADE position Install the upgrade cable provided located in the vinyl pouch in the front of this manual onto the SERIAL header at the card edge see Figure 4 1 Re install the module into the frame Run the upgrade as described in the Upgrading Firmware section of this manual Once the upgrade is c...

Страница 35: ...receive feedback that the configuration has been carried out There are 3 components of SNMP 1 An SNMP manager also known as a Network Management System NMS is a computer running special software that communicates with the devices in the network Evertz VL Fiber demo Manager graphical user interface GUI third party or custom manager software may be used to monitor and control Evertz VistaLINK enable...

Страница 36: ...s control will open a secondary window as shown in Figure 4 2 New Password Window Figure 6 2 New Password Window Optical Threshold This parameter allows the user to set the optical threshold value the range is between 30dBm to 0dBm Vmon Channel This parameter allows the user to set the video in video out channel Output Video On Loss This parameter allows the user to set the output when the output ...

Страница 37: ... the firmware version currently loaded to the card Hardware Revision This parameter displays the most recent hardware revision of the card Link Output Clock Reference This parameter displays the line number that the Clock Reference output is linked to Network Capacity Fill This parameter displays the percentage of the network capacity that is in use Optical Receive Power This parameter display the...

Страница 38: ...nput Video Control Tab There are 8 input channels for the 7708VB 8 for each channel the following two parameters can be set by the user Video Channel Block This parameter allows the user to either block or unblock the video channel Network Video Fill This parameter allows the user to set the network video fill to be either auto SD or HD ...

Страница 39: ...meter can be set by the user Video Channel Block This parameter allows the user to either block or unblock the video channel 6 5 INPUT OUTPUT VIDEO CONTROL Figure 6 5 Input Output Video Control Tab There are 6 input output channels for the 7708VB 8 for each channel the following parameter can be set by the user Video Standard This parameter allows the user to control the video standard being input...

Страница 40: ...ach channel the following parameter can be viewed by the user Input Video Standard This parameter displays the video standard for each input channel 6 7 OUTPUT VIDEO STATUS Figure 6 7 Output Video Status Tab There are 8 output channels for the 7708VB 8 for each channel the following parameter can be viewed by the user Output Video Standard This parameter displays the video standard for each output...

Страница 41: ...t Fiber Transceiver Revision 0 1 Page 31 6 8 CHANNEL 1 AND 2 FAULTS Figure 6 8 Channel 1 and 2 Faults Tab For each channel 1 and 2 the user can enable the listed traps to be monitored and reported The user will know there is a fault when the green indicator turns red ...

Страница 42: ...iber Transceiver Page 32 Revision 0 1 6 9 CHANNEL 3 AND 4 FAULTS Figure 6 9 Channel 3 and 4 Faults Tab For each channel 3 and 4 the user can enable the listed traps to be monitored and reported The user will know there is a fault when the green indicator turns red ...

Страница 43: ... Fiber Transceiver Revision 0 1 Page 33 6 10 CHANNEL 5 AND 6 FAULTS Figure 6 10 Channel 5 and 6 Faults Tab For each channel 5 and 6 the user can enable the listed traps to be monitored and reported The user will know there is a fault when the green indicator turns red ...

Страница 44: ...ber Transceiver Page 34 Revision 0 1 6 11 CHANNEL 7 AND 8 FAULTS Figure 6 11 Channel 7 and 8 Faults Tab For each channel 7 and 8 the user can enable the listed traps to be monitored and reported The user will know there is a fault when the green indicator turns red ...

Страница 45: ...SDI plus Ethernet Fiber Transceiver Revision 0 1 Page 35 6 12 FAULT NOTIFICATION Figure 6 12 Fault Notification Tab These traps can be set to monitor the parameters of the 7708VB 8 the user will know there is a fault when the green indicator turns red ...

Страница 46: ...7708VB 8 HSE User Manual 8 SDI ASI or 6 HD SDI plus Ethernet Fiber Transceiver Page 36 Revision 0 1 This page left intentionally blank ...

Страница 47: ...ADE PROCEDURE Ensure that the 7708VB 8 is running the latest firmware to check this simply right click on the cards address in VLPro Client and select Version Information Figure 7 1 Product Version Drop down Menu This will open a window that displays all of the current version information loaded onto the 7708VB 8 ...

Страница 48: ... To upgrade the firmware locate the latest jar files which can be found on the Evertz website Open VLPro Client and navigate to the top tool bar Locate the Help drop down menu and select Apply Update Figure 7 3 Product Update Drop down menu Another drop down menu should appear at this point select Product Figure 7 4 Apply Update Option ...

Страница 49: ... you want to select the latest jar file for the 7708VB 8 from its saved location on the computer and select Open Figure 7 5 Jar File Directory Location At this point the VLPro Server will send a message asking to Restart select Yes This will apply the update firmware to the 7708VB 8 Figure 7 6 Alarm Server Restart Notification ...

Страница 50: ...7708VB 8 HSE User Manual 8 SDI ASI or 6 HD SDI plus Ethernet Fiber Transceiver Page 40 Revision 0 1 This page left intentionally blank ...