background image

 
2430GDAC GLink D to A Converter 

2430GDAC - 8

 Revision 

1.3

 

6. 

UPGRADING THE FIRMWARE 

The 2430GDAC module contains firmware that is contained in a FLASH EPROM device.  From time to 
time firmware updates will be provided to add additional features to the unit.  The 2430GDAC module is 
fitted with a COM port connector that can be connected to a PC with a straight through cable.  The 
following procedure will allow you to upload new firmware from your computer. 
 

6.1. REQUIREMENTS 

You will need the following equipment in order to update the 2430GDAC Firmware  

• 

PC with available communications port.  The communication speed is 115200 baud, therefore a 486 
PC or better with a 16550 UART based communications port is recommended.  

• 

“Straight-thru” serial extension cable (DB9 female to DB9 male). 

• 

Terminal program that is capable of Xmodem file transfer protocol (such as HyperTerminal). 

• 

New firmware supplied by Evertz. 

 

6.2. 

UPDATE PROCEDURE  

6.2.1.  Part 1 – Configuring the Unit for Firmware Upgrades  

1.  Connect the 9 pin male connector on the straight through serial extension cable to the COM port on 

the end of the 2430GDAC.  Connect the 9 pin female connector to the PCs’ RS-232 communications 
port. 

 

6.2.2.  Part 2 – Terminal Program Setup  

2.  Start the terminal program.  
3.  Configure the port settings of the terminal program as follows:  
 

Baud 

115200 

Parity 

no 

Data bits 

Stop bits 

Flow Control 

None 

 
4.  Apply power to the 2430GDAC.  After the unit powers up, a banner with the boot code version 

information should appear in the terminal window.  The cursor to the right of the word “BOOT>” should 
be spinning for about 5 seconds then the unit will continue to boot.  

 

For example:  
 

EVERTZ MCF5272 MONITOR 2.3 BUILD 3 (66 MHZ) 
COPYRIGHT 1997, 1998, 1999, 2000, 2001, 2002 EVERTZ MICROSYSTEMS LTD. 
28F160C3B FLASH DETECTED 
PROD=2430GDAC 
MCF5272 COLD BOOT> |  

 

5.  The following is a list of possible reasons for failed communications:  
 

• 

Defective serial cable.  

• 

Wrong communications port selected in the terminal program.  

• 

Improper port settings in the terminal program (Refer to step 3 for settings). 

Содержание 2430GDAC

Страница 1: ...material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 2430GDAC GLink D to A Converter Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the Downconverter All rights reserved No part of this publication may be reproduced without the express...

Страница 2: ...IGITAL DEVICE OR PERIPHERAL This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed an...

Страница 3: ...nly and are not warranties of future performance either express or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liabili...

Страница 4: ...2430GDAC GLink D to A Converter Revision 1 3 This page left intentionally blank ...

Страница 5: ... Handling and Connecting Fibers 4 2 5 3 Making Sure the Optical Fibers are Clean 4 3 SPECIFICATIONS 5 3 1 COAXIAL GLINK INPUT 5 3 2 FIBER GLINK INPUT 5 3 3 RE CLOCKED COAXIAL GLINK OUTPUT 5 3 4 VIDEO OUTPUT 5 3 5 DVI DIGITAL VIDEO OUTPUT 5 3 6 RGB ANALOG VIDEO OUTPUT 5 3 7 ELECTRICAL 5 3 8 PHYSICAL 6 4 STATUS LED S 6 5 USER CONTROLS 7 5 1 INPUT SOURCE SELECTION 7 5 2 VIDEO RESOLUTION 7 6 UPGRADING...

Страница 6: ...3 Uploading the New Firmware 9 6 2 4 Part 4 Completing the Upgrade 9 Figures Figure 1 1 2430GDAC Block Diagram 1 Figure 2 1 2430GDAC Module Connections 2 Tables Table 2 1 DVI I Output Connector 3 Table 2 2 COM Port Pinout 3 Table 5 1 DIP Switch Functions 7 Table 5 2 Input Source Switch Settings 7 Table 5 3 Input Source Switch Settings 7 Table 5 4 Fixed Resolution Settings 7 ...

Страница 7: ... Evertz 3000PPMV and 3000PPMG Multi video Monitoring Processors Features Display resolution capability up to UXGA 1600x1200 at a 60Hz refresh rate DVI I Digital and Analog video output Autodetection of display resolution with manual override One reclocked GLink coaxial output for connection to a second 2430GDAC or other GLink compatible products Autodetection of GLink signal loss Operation with si...

Страница 8: ...ing type power supply cord to the power entry module on the DC voltage adapter The power cord should be minimum 18 AWG wire size type SST marked VW 1 maximum 2 5 m in length The DC cable of the voltage adapter should be connected to the DC power jack on the rear panel A green LED located beside the DVI Out connector will be illuminated when there is power applied to the 2430GDAC 2 2 GLINK IN AND O...

Страница 9: ...ta3 21 Data5 6 DDC Clock 14 5V Power 22 Data5 Clock Shield 7 DDC Data 15 Ground 23 Clock 8 Analog VSYNC 16 Hot Plug Detect 24 Clock C1 Analog RED C2 Analog GREEN C3 Analog BLUE C4 Analog HSYNC C5 Ground Table 2 1 DVI I Output Connector 2 4 FIRMWARE UPGRADE PORT COM Serial port connector for upgrading the 2430GDAC firmware This is a female 9 pin D connector used for connecting to a standard compute...

Страница 10: ...ly be connected in one way and with very good repeatability The fiber interconnect panel that is provided with each product can be ordered with optional SC PC ST PC or FC PC connectors The customer is required to provide the optical fiber with the correct connectors to connect the modules together SC PC ST PC and FC PC interconnection housing and connectors as well as adapters are industry standar...

Страница 11: ...3 3 RE CLOCKED COAXIAL GLINK OUTPUT Connector BNC Signal Level 600mV minimum 3 4 VIDEO OUTPUT Connector DVI I digital analog Output Resolution UXGA 1600x1200 60Hz maximum 3 5 DVI DIGITAL VIDEO OUTPUT Voltage Swing 400mV minimum Output Clock Jitter 150ps maximum Differential Skew 50ps maximum 3 6 RGB ANALOG VIDEO OUTPUT Signal Level Video 1Vpp nominal RGB Sync 4V Impedance 75Ω DC Offset 0V 0 5V 3 7...

Страница 12: ...th mounting flanges 7 2 L x 5 3 W x 1 0 H 166mm L x 136mm W x 26mm H Weight 0 85 lbs 0 38 kg 4 STATUS LED S The locations of the status indicators are shown in Figure 2 1 POWER Indicates that the 2430GDAC is receiving electrical power FAULT When on indicates that the input GLink signal either coaxial or fiber is not being received ...

Страница 13: ...mode DIP 2 Video Source Off Manual Resolution Select On Automatic Resolution Detect Table 5 3 Input Source Switch Settings When in automatic resolution detection mode the 2430GDAC determines the resolution and refresh rate of the incoming GLink video and automatically configures its video output to match When in fixed resolution mode the output video resolution and refresh rate of the 2430GDAC is ...

Страница 14: ...E 6 2 1 Part 1 Configuring the Unit for Firmware Upgrades 1 Connect the 9 pin male connector on the straight through serial extension cable to the COM port on the end of the 2430GDAC Connect the 9 pin female connector to the PCs RS 232 communications port 6 2 2 Part 2 Terminal Program Setup 2 Start the terminal program 3 Configure the port settings of the terminal program as follows Baud 115200 Pa...

Страница 15: ...ram If you do not start the upload within 10 minutes the 2430GDAC boot code will time out You can restart the upgrade process by cycling the power to the unit 12 The boot code will indicate whether the operation was successful upon completion of the upload For example UPLOAD OKAY 7700PB COLD BOOT 13 The following is a list of possible reasons for a failed upload If you get the message transfer can...

Отзывы: