- 6 - 

e.  Please carefully select the installation position of your device, as to make 

sure the GSM has good signal. Please see Test Mode Point 4. 

f.  The SIM card must not be expired. 
g.  The “Show Caller ID” function must be enabled on the mobile phones for 

the host phone number and SMS phone number for the host to determine if 
the phone number is authorized to use the SMS function.   

 

4-1 Alarm Message Play Function 

4-1-1 Alarm Message Play Time:

 maximum cycle length is 30 seconds. 

4-1-2  Record  Alarm  Message:

  the  Help  message  can  be  recorded;  Alarm 

message  up  to  10  seconds,  and  will  be  played  every  time  when  a 
condition is triggered. 

4-1-3  Replay  Alarm  Message:

  hold  the  Record  button  to  play  the  Alarm 

message. 

4-1-4  Confirm  Telephone  Times:

  the  default  is  3  times.  Pressing  the  “

*

” 

button on a remote phone will enter the remote control procedure. Press 
8  again  to  confirm  and  the  confirmed  call  will  be  temporarily  canceled. 
When  confirmed  times  have  been  reached  all  phone  calls  will  be 
canceled.   

4-1-5 Call Attempts:

 the default is 3 times. All attempted calls will count as 1 

times  before  the  Confirm  Times  has  been  reached.  The  call  will  stop 
when the maximum call value has been reached. 

 

4-2 Special Functions 

4-2-1 Warning SMS Notice and Host Parameter Setup 

When  the  host  generates  an  alarm,  an  SMS  will  be  sent  first  from  the 
preset SMS phone number to notify the user on the condition.   

4-2-2 Alarm Voice Automatic Call 

When  the  host generates  an  alarm, the  preset  voice  telephone  number 
and help message will automatically call and notify the user of an alarm 
condition. Please refer to the Trigger Call Procedures. 

4-2-3 System Disarm Notification 

When the RFID Tag is on the Host tag sensor, an SMS will be sent to the 
Host Phone Number if Fully Arm is set to Disarm and notify the user on 
who disarmed the system.   

 

4-3 Built-In Automatic Voice Dial 

4-3-1 How to enter Reverse Control:   

The user may press “

*

” when hearing the USC423A alarm call. The alarm 

will  stop  and  the  device  will  enter  “Reverse  Control”  mode  and  wait  for 
function input. Press the “#” or wait 30 seconds to end the call (Listen In 
or Two Way Talk excluded).   

4-2-2 Reverse Control Procedures: 

a.

  Press “

*

” and input Key (0 – 9 and *) after the message to enter Remote 

Control  Procedures.  Timeout  will  occur  if  no  Keys  were  input  after  30 
seconds. 

b.

  When Key = 1 (Full Arm and send SMS) 

c.

  When Key = 2 (Part-Arm and send SMS) 

d.

  When Key = 3 (Set the Siren to turn on Alarm and send SMS) 

e.

  When Key = 4 (Set the Siren to turn off Alarm and send SMS) 

f.

 

When Key = 6 (Listen to the Alarm message again) 

g.

  When Key = 7 (Enter Listen In Mode. Timeout will occur after 5 minutes) 

h.

  When Key = 8 (Cancel telephone notice and send SMS) 

i.

 

When  Key  =  9  (Enter  Two  Way  Talk  Mode.  Timeout  will  occur  after  5 
minutes) 

j.

 

When Key = 0 (Disarm and send SMS) 

4-2-3 Trigger Call Procedures 

When an event triggers, the device will call the preset number and play 
the  alarm  message  for  30  seconds.  Pressing  a  Key  will  enter  Remote 
Control.  The  call  will  end  after  30  seconds  and  contact  the  next  set  of 
numbers and repeat the steps. 

4-2-4 SMS Functions 
 

Setup 

SMS Sent 

Operation 

SMS in Return 

Operation 

Menu 1 

 

 

0 Disarm 
1 Arm 
2 Partial Arm 
3 Two-way Talk 
4 Listen In 
00 System Status 
? Phone Number Setup 

Содержание USC423A

Страница 1: ...d a key tone will sound when Key Tone is enabled 3 1 Definition of LEDs LED Indication GSM Signal LED Flashing once every second Registering with host device Flashing once every three seconds Successful registration with host device Off No AC power REC LED Flashing Recording On Playback Monitoring On Speaker playback ARM LED On Arm Mode Flashing Arm Mode Exit Delay PARM LED On Partial Arm Mode Fla...

Страница 2: ... Dialer nter password 01 Default is ON Alarm Type 2 No siren Dialer only Enter password 02 Siren will not sound during alarm DISARM Mode Disarm Key flashes Test Mode Enter password 03 A doorbell sound will be generated when a device signal is received Hold key 7 for 3 or more seconds Test GSM receiving signal strength Hold key 8 for 3 or more seconds Turn on off the Wireless Siren Hold key 9 for 3...

Страница 3: ...er will cause an Entry Delay Add Devices 24HRs Intruder Mode Enter password 15 4 Sensors triggered when Disarmed Partial Armed Fully Armed will cause an immediate alarm 24 hours Note Fire Sensors Flood Sensors must choose this Type 24 hours Delete Sensor Enter password 20 Key 1 Delete all sensors Enter password 20 Key 1 1 9 Delete sensor 1 9 Enter password 20 Key 1 0 Delete all sensors after 10 De...

Страница 4: ...A long beep will sound if the password is correct Three beeps will sound if the password is incorrect b If the password is correct the system will enter the Exit Delay countdown The Arm LED and beep tone will flash and sound once every second c When the countdown reaches 5 second the beep tone will sound twice every second d After the countdown is complete the system will time out and enter Arm Mo...

Страница 5: ...he configured warning procedure if all doors windows are normal the alert sounds will turn off You may also check beforehand Pressing the Arm Key will check all doors and windows under Fully Armed and display LED opened doors or windows for 3 seconds Pressing the Partial Arm Key will check all doors and windows under Partial Armed and display LED opened doors or windows for 3 seconds 3 9 RF Anti J...

Страница 6: ...essage will automatically call and notify the user of an alarm condition Please refer to the Trigger Call Procedures 4 2 3 System Disarm Notification When the RFID Tag is on the Host tag sensor an SMS will be sent to the Host Phone Number if Fully Arm is set to Disarm and notify the user on who disarmed the system 4 3 Built In Automatic Voice Dial 4 3 1 How to enter Reverse Control The user may pr...

Страница 7: ...4 Call back from Alarm system console Note 7 System Status Display 00 System Disarmed System Armed System Partial Armed Entry Exit Delay Time xx Seconds Siren Volume Mute Low High Siren Ringing Time xx Minutes Set Alarm Voice Phone Number 5 Note1 Note 5 TEL 1 2 3 4 5 Forward Edit Send TEL 1 0932XXXXXX 2 0922XXXXXX 3 0928XXXXXX 4 0965XXXXXX 5 0932XXXXXX Set Phone Number Successfully Set Alarm SMS P...

Страница 8: ... Change Zone 2 Name 92 Note 2 Note5 Zone2 Name Zone2 Forward Edit Send Zone2 Name Entrance Door Sensor2 Set Zone Name Successfully Change Zone 3 Name 93 Note 2 Note5 Zone3 Name Zone3 Forward Edit Send Zone3 Name Entrance Door Sensor3 Set Zone Name Successfully Change Zone 4 Name 94 Note 2 Note5 Zone4 Name Zone4 Forward Edit Send Zone4 Name Entrance Door Sensor4 Set Zone Name Successfully Change Zo...

Страница 9: ... Name Entrance Door Sensor8 Set Zone Name Successfully Change Zone 9 Name 99 Note 2 Note5 Zone9 Name Zone9 Forward Edit Send Zone9 Name Entrance Door Sensor9 Set Zone Name Successfully Change RFID Tag Names 10 Note 2 Note5 Tag Names 1 2 3 4 Forward Edit Send Tag Names 1 Jack 2 Daniel 3 Henry 4 Joe Set Tag Names Successfully Set Entry exit Delay Time 11 Note 5 Entry Exit Delay Time 0 240 sec 15 For...

Страница 10: ...d Status Report SMS Sent SMS in Return AC Adaptor Power Off Note 6 System AC Power Loss AC Adaptor Power On Note 6 System AC Power Return Tag Disarmed Note 6 For Tag 1 Tag 4 Send Tag name For Other Tags Send Tag xx Zone Trigger For Zone 1 Zone 9 Send Zone name is triggered For Other Zones Send Zone xx is triggered Zone Tamper For Zone 1 Zone 9 Send Zone name tamper is triggered For Other Zones Sen...

Страница 11: ...uthorized mobile phone number to receive the host model number and software version 5 Troubleshooting 5 1 System Reset The user may use the system reset button to return the device to factory default settings The default password is 1234 Please note that all configurations including recorded alarm messages contact lists and learnt ID codes will be deleted a Take the device off the wall b Remove al...

Страница 12: ... AC power insert them back and try again Specifications Operating temperature range 10 C to 50 C Operating humidity 85 RH at 30 C Adapter 9V DC 1A Battery type Li ion cell 2000mAh 3 7V Transmission range Outdoors 150m Open space for front and sides Frequency range 868 35 MHz Specifications are subject to change without notice USC423A0517 ENVIRONMENTAL CONCERNS Please DO NOT dispose of electrical a...

Отзывы: