3-2 Operation on Control Panel 

 
Note: 

Please set the Host Phone Number and set the Record Alarm Message 

first so that the GSM notification can function normally. 

 
Please refer to the operation table. 

Function 

Enter Key   

Explanation 

Exit  Delay:  Arm  Key  LED  flashes  and  beeps 
(faster beeps at 5 second countdown) 

ARM Mode 

Enter pa   

 

ARM Mode: Arm Key LED turns on 

Exit  Delay:  Arm  Key  LED  flashes  and  beeps 
(faster beeps at 5 second countdown) 

Partial Arm 
Mode 

Enter pa   

 

Partial Arm Mode: Partial Arm Key LED turns on 

DISARM Mode 

 

Enter pa   

 

Disarm Mode: Disarm Key LED turns on 

** Please do following operations under “DISARM Mode” 

1. Start recording alarm message (about 10 
seconds) Playback will start automatically after 
the record is complete 
2. Press            to stop recording if message is 
shorter than 10 seconds 

 

Record: Record Key LED will flash 

Record Alarm 
Message 

 

Enter pa            + 

 

Playback: Record Key LED turns on 

Alarm Type 1 

Siren will sound during alarm 

(Siren and 
Dialer) 

nter pa 01 +   

 

(Default is ON) 

Alarm Type 2 

(No siren, Dialer 
only) 

Enter pa 02 +   

 

Siren will not sound during alarm 

DISARM Mode: Disarm Key flashes 

Test Mode 

Enter pa 03 +   

 

A doorbell sound will be generated when a 
device signal is received 

Hold key 7 for 3 or more seconds: Test GSM 
receiving signal strength 

Hold key 8 for 3 or more seconds: Turn on / off 
the Wireless Siren 

Hold key 9 for 3 or more seconds: Test 
telephone SMS 

Press Disarm key to exit Test Mode   

HA-70FA 

Keys 1 – 8 will toggle House Code Dip Switch 
positions   

Dip Switch at ON position: Key LED on 

Dip Switch at OFF position: Key LED off 

Keys 1 – 8 LEDs will display Dip Switch ON 
positions   

Press Partial Arm Key to save settings 

(Default Dip Switch position: 1111000) 

SE822 

Enable / Disable Wireless Siren 

When Enabled: Key 0 LED turns on 

When Disabled: Key 0 LED turns off 

Press Partial Arm Key to save settings 

Wireless Siren 
Setting 

Enter pa 04 +     

 

(Default: Wireless Siren Disabled) 

Enter pa 05+ 1 + 

 

Turn On 

RF 
Anti-Jamming 
Detection 

Enter pa 05+ 2 +   

 

Turn Off (Default) 

Change 
Password 

Enter old pa 06 + new 
pa   

Default Password: 1234 

 

Key Tone 

Enter pa 07 + 1 +       

 

Turn On (Default) 

 

Содержание USC423A

Страница 1: ...d a key tone will sound when Key Tone is enabled 3 1 Definition of LEDs LED Indication GSM Signal LED Flashing once every second Registering with host device Flashing once every three seconds Successful registration with host device Off No AC power REC LED Flashing Recording On Playback Monitoring On Speaker playback ARM LED On Arm Mode Flashing Arm Mode Exit Delay PARM LED On Partial Arm Mode Fla...

Страница 2: ... Dialer nter password 01 Default is ON Alarm Type 2 No siren Dialer only Enter password 02 Siren will not sound during alarm DISARM Mode Disarm Key flashes Test Mode Enter password 03 A doorbell sound will be generated when a device signal is received Hold key 7 for 3 or more seconds Test GSM receiving signal strength Hold key 8 for 3 or more seconds Turn on off the Wireless Siren Hold key 9 for 3...

Страница 3: ...er will cause an Entry Delay Add Devices 24HRs Intruder Mode Enter password 15 4 Sensors triggered when Disarmed Partial Armed Fully Armed will cause an immediate alarm 24 hours Note Fire Sensors Flood Sensors must choose this Type 24 hours Delete Sensor Enter password 20 Key 1 Delete all sensors Enter password 20 Key 1 1 9 Delete sensor 1 9 Enter password 20 Key 1 0 Delete all sensors after 10 De...

Страница 4: ...A long beep will sound if the password is correct Three beeps will sound if the password is incorrect b If the password is correct the system will enter the Exit Delay countdown The Arm LED and beep tone will flash and sound once every second c When the countdown reaches 5 second the beep tone will sound twice every second d After the countdown is complete the system will time out and enter Arm Mo...

Страница 5: ...he configured warning procedure if all doors windows are normal the alert sounds will turn off You may also check beforehand Pressing the Arm Key will check all doors and windows under Fully Armed and display LED opened doors or windows for 3 seconds Pressing the Partial Arm Key will check all doors and windows under Partial Armed and display LED opened doors or windows for 3 seconds 3 9 RF Anti J...

Страница 6: ...essage will automatically call and notify the user of an alarm condition Please refer to the Trigger Call Procedures 4 2 3 System Disarm Notification When the RFID Tag is on the Host tag sensor an SMS will be sent to the Host Phone Number if Fully Arm is set to Disarm and notify the user on who disarmed the system 4 3 Built In Automatic Voice Dial 4 3 1 How to enter Reverse Control The user may pr...

Страница 7: ...4 Call back from Alarm system console Note 7 System Status Display 00 System Disarmed System Armed System Partial Armed Entry Exit Delay Time xx Seconds Siren Volume Mute Low High Siren Ringing Time xx Minutes Set Alarm Voice Phone Number 5 Note1 Note 5 TEL 1 2 3 4 5 Forward Edit Send TEL 1 0932XXXXXX 2 0922XXXXXX 3 0928XXXXXX 4 0965XXXXXX 5 0932XXXXXX Set Phone Number Successfully Set Alarm SMS P...

Страница 8: ... Change Zone 2 Name 92 Note 2 Note5 Zone2 Name Zone2 Forward Edit Send Zone2 Name Entrance Door Sensor2 Set Zone Name Successfully Change Zone 3 Name 93 Note 2 Note5 Zone3 Name Zone3 Forward Edit Send Zone3 Name Entrance Door Sensor3 Set Zone Name Successfully Change Zone 4 Name 94 Note 2 Note5 Zone4 Name Zone4 Forward Edit Send Zone4 Name Entrance Door Sensor4 Set Zone Name Successfully Change Zo...

Страница 9: ... Name Entrance Door Sensor8 Set Zone Name Successfully Change Zone 9 Name 99 Note 2 Note5 Zone9 Name Zone9 Forward Edit Send Zone9 Name Entrance Door Sensor9 Set Zone Name Successfully Change RFID Tag Names 10 Note 2 Note5 Tag Names 1 2 3 4 Forward Edit Send Tag Names 1 Jack 2 Daniel 3 Henry 4 Joe Set Tag Names Successfully Set Entry exit Delay Time 11 Note 5 Entry Exit Delay Time 0 240 sec 15 For...

Страница 10: ...d Status Report SMS Sent SMS in Return AC Adaptor Power Off Note 6 System AC Power Loss AC Adaptor Power On Note 6 System AC Power Return Tag Disarmed Note 6 For Tag 1 Tag 4 Send Tag name For Other Tags Send Tag xx Zone Trigger For Zone 1 Zone 9 Send Zone name is triggered For Other Zones Send Zone xx is triggered Zone Tamper For Zone 1 Zone 9 Send Zone name tamper is triggered For Other Zones Sen...

Страница 11: ...uthorized mobile phone number to receive the host model number and software version 5 Troubleshooting 5 1 System Reset The user may use the system reset button to return the device to factory default settings The default password is 1234 Please note that all configurations including recorded alarm messages contact lists and learnt ID codes will be deleted a Take the device off the wall b Remove al...

Страница 12: ... AC power insert them back and try again Specifications Operating temperature range 10 C to 50 C Operating humidity 85 RH at 30 C Adapter 9V DC 1A Battery type Li ion cell 2000mAh 3 7V Transmission range Outdoors 150m Open space for front and sides Frequency range 868 35 MHz Specifications are subject to change without notice USC423A0517 ENVIRONMENTAL CONCERNS Please DO NOT dispose of electrical a...

Отзывы: