background image

                                                                                            Copyright 

Ž

 1997

FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection
against harmful interference in a residential installation.  This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.  However, there is no guarantee that interference
will not occur in a particular installation.  If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

-  Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.

Consult the dealer or an experienced radio/TV technician for help.

FCC Caution:

 Any changes or modifications not expressly approved by the party responsible for

compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.

Содержание HA 51

Страница 1: ...s and an overview A Illustrated Instructions Hand Transmitter HA 51R 1 Use a small cross slotted Phillips screw driver and open the hand transmitter by removing the screw on the rear side and then by removing the cover To do this insert the cross slotted screw driver between the halves of the casing and pry them open 2 Use the now visible 8 setting switch to set your own house code To do this set ...

Страница 2: ...duration This duration is 10 minutes with closed jumper 3 minutes with open jumper 10 Now connect the power supply to the mains supply 11 A single beep tone signals that the central station is in standby mode and the POWER LED lights up 12 Press the OFF key on the hand transmitter Doing so the central station automatically learns your house code which will be confirmed by beep beep Magnetic Contac...

Страница 3: ...ulge on the inside Slide the appropriate cover onto the sensor Make sure that the cover is completely closed 2 Function control of sabotage protection works only with alarm version according to point 17 A Open the cover again The LED on the sensor must light up for 1 2 secs thus indicating that the sabotage protection is working properly Close the cover again 3 Function control of magnetic contact...

Страница 4: ...manent attachment using screws use a screw driver to pierce through the bottom at the marked location Fig 9 22 The cut for the upper screw is located on the rear side of the sensor First insert this screw use a dowel if necessary and let the screw protrude for approx 3 mm from the wall Hang the sensor on this screw and now mark the position of the lower screw on the wall After drilling a hole here...

Страница 5: ... experiences interferences for longer than 5 secs This may occur when e g a radio phone radio headphones or another transmitter is operated in close vicinity of the central station It is recommended to keep a distance of minimum 3 m to such devices B Before replacing batteries of the sensors you have to interrupt the entire power supply to the central station Disconnect the emergency battery if in...

Страница 6: ...e phone dialing device S 126 with power DIAL impuls output to activate the phone dialing device S 126 during an alarm Close device after having established all connections Press OFF key on hand transmitter Æ 2 x beeps code is memorized Error Reason Corrective measures Central station is not operable Power supply is not connected Wall plug is without current Connect power supply Check fuse Sensors ...

Страница 7: ...evision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an...

Страница 8: ...space which is transmitted by HA51M or HA51P 60M Min For free space which is transmitted by HA51R Old Version 70M For HA51R 8 External Output for Auto Dialer S126 for N C use only 9 External Output for Alarm System S105 S125 HA52E when connect with HA52E the function off tamper return is non exist 10 ANTI JAMMING module for Option 11 Receive RF Signal have ARM DISARM PANIC INSTANT PARM DELAY 12 Af...

Страница 9: ...DC 5 Trigger interval timing 60 20 Sec 6 RF signal 6 1 Transmit timing 1 0 2 Sec 6 2 Frequency 433 92MHz 150 KHz 6 3 Power Radiation 35 dBm at 9V DC the site 30cm between HA51P and spectrum s ANT 7 Duty Cycle 35 8 Antenna Type PCB layout 9 Antenna Gain 15dBi 1 SEC 10 Transmission Cycle 1 CYCLE 5 SEC Model Number HA51R FCC 1 Operating Voltage 12 V DC ALKALINE BATTERY 2 Standby Current 0uA 3 Operati...

Отзывы: