Copyright
1997
B) Short Reference
1. Open hand transmitter, set desired code using the 8-setting DIP switch, insert battery, and close
hand transmitter again.
1. Open magnetic contact sensor, set the same code as for the hand transmitter, mount at desired
location, insert battery, and replace cover.
A) Cover with bulge
: Alarm trigger for armed system ONLY by opening the battery
cover when system is switched off.
B) Cover without bulge
: 24-hr. alarm = alarm trigger for system switched on and off. No
sabotage alarm is triggered.
2. Open PIR sensor, set the same code as for the hand transmitter, mount at desired location, insert
battery, and replace cover.
A)
LED is lit
for approx. 1 min. (warm-up phase).
B)
LED extinguishes
= TEST MODE. LED lights up during any movement in the surveillance area.
C) If no movement is detected for 1 min., then the sensor switches to AUTO MODE = sensor is armed.
LED lights up during any movement also after TEST MODE = LOW BATTERY
3. Open central station, connect power supply (white = +pole), if necessary install emergency battery,
select alarm duration with jumpers (closed = 10 min., open = 3 min.)
Connections:
P+
free
V+
positive pole power supply
V-
negative pole
POW+
+ 12V to supply the phone dialing device S-126 with power
DIAL
impuls output to activate the phone dialing device S-126 during an alarm
Close device after having established all connections.
Press OFF key on hand transmitter (
Æ
2 x beeps = code is memorized.)
Error
Reason
Corrective measures
Central station is not
operable
Power supply is not connected.
Wall plug is without current.
Connect power supply.
Check fuse.
Sensors are not operable
Battery is dead.
Incorrect house code set.
Replace battery.
Set correct house code.
Sensors do not trigger
any alarm
Incorrect house code set
House code is not transmitted.
Set correct house code.
Press OFF key on hand transmitter.
False alarm
Interfering station nearby.
Movement of doors, or windows
caused by wind.
Temperature changes
Find and remove reason, if possible,
enlarge distance between central station
and other electrical devices.
Tightly close, or fix doors and windows.
Do not direct PIR sensor to ventilation
vents, radiators, and similar devices
(see point 20)
Before opening doors or windows secured for 24 hrs., you must unplug the power supply from
the wall plug and disconnect one of both connections to the emergency battery. When you
forget these steps, an alarm will be triggered. Therefore, choose version B only for windows
and doors which are normally always closed.
After resuming operation, press the OFF key on the hand transmitter. (Points 11+12)