15.  You can use the enclosed double-sided adhesive

tape to mount the sensor and the magnet. If you
prefer a permanent attachment with screws, use a
screw driver to pierce through the bottom at the
marked location (Fig. 7).

  

The cut for the upper screw is located on the rear
side of the sensor. First, insert this screw, use a
dowel if necessary, and let the screw protrude for
approx. 3 mm from the wall. Hang the sensor on
this screw and now mark the position of the lower
screw on the wall. After drilling a hole here, or
insertion of a dowel, tighten the lower screw (Fig. 8).

16.   While mounting the magnet, make sure that the distance between the sensor and the magnet is

as small as possible, and that the arrow markings are at the same height. The distance should
not exceed 5 mm (Fig. 3).

1.   Set the 8-setting switch to the same house code as the hand transmitter.

Insert the enclosed battery (23A, 12V) by observing the correct polarity.

Now decide, in which instance the sensor should trigger an alarm:
A)

  ONLY for armed system

Æ

 Use cover 

WITH

 bulge on the inside.   

B)

  ALSO for switched-off system (24 hrs.)

Æ

 Use cover 

WITHOUT

 bulge on the inside.

Slide the appropriate cover onto the sensor. Make sure that the cover is completely closed.
  

2.   Function control of sabotage protection (works only with alarm version according to point 17 A):

Open the cover again. The LED on the sensor must light up for 1 - 2 secs., thus indicating that
the sabotage protection is working properly. Close the cover again.

3.   Function control of magnetic contact: Close the secured door, or window. By opening the door, or

window, the LED lights up for 1 - 2 secs. and then extinguishes again.

ATTENTION!

 The sensor is equipped with a 

power saving switch

. After its activation (open

window), the sensor transmits an alarm signal to the central station, and then switches itself off
completely. The sensor will be reactivated as soon as you close the window. Thereby, the
battery’s life span is extended significantly when doors and windows are left open for several
hours, for instance in Summer.

Before opening doors or windows secured for 24 hrs., you must unplug the power supply from
the wall plug and disconnect one of both connections to the emergency battery. If you forget
these steps, an alarm will be triggered. Therefore, choose version B only for windows and
doors which are normally always closed.

After resuming operation, press the OFF key on the hand transmitter. (Points 11+12)

Fig. 7

Fig. 8

Содержание HA 51

Страница 1: ...s and an overview A Illustrated Instructions Hand Transmitter HA 51R 1 Use a small cross slotted Phillips screw driver and open the hand transmitter by removing the screw on the rear side and then by removing the cover To do this insert the cross slotted screw driver between the halves of the casing and pry them open 2 Use the now visible 8 setting switch to set your own house code To do this set ...

Страница 2: ...duration This duration is 10 minutes with closed jumper 3 minutes with open jumper 10 Now connect the power supply to the mains supply 11 A single beep tone signals that the central station is in standby mode and the POWER LED lights up 12 Press the OFF key on the hand transmitter Doing so the central station automatically learns your house code which will be confirmed by beep beep Magnetic Contac...

Страница 3: ...ulge on the inside Slide the appropriate cover onto the sensor Make sure that the cover is completely closed 2 Function control of sabotage protection works only with alarm version according to point 17 A Open the cover again The LED on the sensor must light up for 1 2 secs thus indicating that the sabotage protection is working properly Close the cover again 3 Function control of magnetic contact...

Страница 4: ...manent attachment using screws use a screw driver to pierce through the bottom at the marked location Fig 9 22 The cut for the upper screw is located on the rear side of the sensor First insert this screw use a dowel if necessary and let the screw protrude for approx 3 mm from the wall Hang the sensor on this screw and now mark the position of the lower screw on the wall After drilling a hole here...

Страница 5: ... experiences interferences for longer than 5 secs This may occur when e g a radio phone radio headphones or another transmitter is operated in close vicinity of the central station It is recommended to keep a distance of minimum 3 m to such devices B Before replacing batteries of the sensors you have to interrupt the entire power supply to the central station Disconnect the emergency battery if in...

Страница 6: ...e phone dialing device S 126 with power DIAL impuls output to activate the phone dialing device S 126 during an alarm Close device after having established all connections Press OFF key on hand transmitter Æ 2 x beeps code is memorized Error Reason Corrective measures Central station is not operable Power supply is not connected Wall plug is without current Connect power supply Check fuse Sensors ...

Страница 7: ...evision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an...

Страница 8: ...space which is transmitted by HA51M or HA51P 60M Min For free space which is transmitted by HA51R Old Version 70M For HA51R 8 External Output for Auto Dialer S126 for N C use only 9 External Output for Alarm System S105 S125 HA52E when connect with HA52E the function off tamper return is non exist 10 ANTI JAMMING module for Option 11 Receive RF Signal have ARM DISARM PANIC INSTANT PARM DELAY 12 Af...

Страница 9: ...DC 5 Trigger interval timing 60 20 Sec 6 RF signal 6 1 Transmit timing 1 0 2 Sec 6 2 Frequency 433 92MHz 150 KHz 6 3 Power Radiation 35 dBm at 9V DC the site 30cm between HA51P and spectrum s ANT 7 Duty Cycle 35 8 Antenna Type PCB layout 9 Antenna Gain 15dBi 1 SEC 10 Transmission Cycle 1 CYCLE 5 SEC Model Number HA51R FCC 1 Operating Voltage 12 V DC ALKALINE BATTERY 2 Standby Current 0uA 3 Operati...